Delta Check System for Detection and Further Management of Laboratory Errors : First Report Graphical Presentation of Results
スポンサーリンク
概要
- 論文の詳細を見る
The delta check system is effective for detecting errors that may occur during the whole course of tests, from the time a laboratory test is ordered until it is interpreted. This system detects errors that exceed the preestablished values by comparing present data with the most adjacent ones in all items for each case. Graphical presentation of delta-checked data led to easier judgement as to whether such a difference is due to erroneous testing or changes in the patient's condition on the basis of whether a difference in values is limited to a particular item or is common to pathologically associated multiple ones. Furthermore, since test items were classified by analytical instruments, it became easier for us to determine at which process of the testing an error occurred. This report gives the present status of utilization of delta check system in our laboratory.
- 東海大学の論文
著者
-
Niwa Masaharu
Department Of Clinical Pathology School Of Medicine Tokai University
-
Miyamoto Motoaki
Central Cilinical Laboratory Tokai University Hospital
-
Shimizu Hiroshi
Central Clinical Laboratory Tokai University Hospital:(present Address)department Of Medical Informa
関連論文
- Quantitative Thin-Layer Chromatography with a Flame Ionization Detector for Serum Lipid Measurements in the Routine Clinical Laboratory
- A Case of Acute Myeloblastic Leukemia with Chromosomes Showing 46, XY=11/46, XY, 21q-=39
- A Variant Translocation (11; 22) (p15; q11) in a Patient with Chronic Myelocytic Leukemia
- Interpretation of Pathophysiology by Laboratory Data (3) A Consultation Program Based on Clinical Laboratory Data
- Studies on the Rapid Determination of Glucose Level in Blood Using the Enzyme Electrode, the "Glucose Meter"
- Evaluation of an Automated Differential Leukocyte Counting System "Hematrak"
- Study on Erythrocyte Lipids and Osmotic Fragility in Elderly People with Anemia
- The Current Concepts of "Normal Values" and "Clinical Reference Values" in the Clinical Laboratory : Trials for Determining Clinical Reference Values of the Tokai University Hospital
- Drug-Induced False Positive Tests for Protein in Urine Specimens from the Automated Multiphasic Health Testing Services of Tokai University Hospital
- Standard-Deviation-Index-Pattern Analysis of Blood Chemical Data in Health Check-Ups for Chronic Liver Disease : A Clinico-Pathological Study
- A Case with Silent Type of Pseudo-Acholinesterasemia
- Plasma Antithrombin III, _-Plasmin Inhibitor and Plasminogen Activities in Cases of Various Liver Diseases
- Study of Urinary Specific Gravity by Reagent Strip Method
- Interpretaion of Patho-physiology by Laboratory Data (4) Cases of Hypernutritional Fatty Liver
- Interpretation of Pathophysiology by Laboratory Data (1) Graphic Display of Data, Static Pattern
- A Practical Evaluation of Accuracy with the Standard Deviation Index (SDI) Chart Method Second Report : Report Covering the Period from April 1980 to March 1983
- Delta Check System for Detection and Further Management of Laboratory Errors : Second Report. Computer Program to Identify Laboratory Errors
- Delta Check System for Detection and Further Management of Laboratory Errors : First Report Graphical Presentation of Results
- Interpretation of Pathophysiology by Laboratory Data (2) Graphic Display of Data, Dynamic Pattern