A Practical Evaluation of Accuracy with the Standard Deviation Index (SDI) Chart Method Second Report : Report Covering the Period from April 1980 to March 1983
スポンサーリンク
概要
- 論文の詳細を見る
To evaluate the accuracy of laboratory data for 18 items determined with an Technicon SMAC (Sequential Multiple Analyzer Computer), the SDI chart method was used in investigating the data according to five kinds of control survey programs from April 1980 to March 1983. The results can be summarized as follows: 1) Inorganic phosphorus showed a gradual downward shift, arriving at the minus side of SDI in all control surveys. 2) Potassium showed a particularly large fluctuation as was the case in the previous evaluation. 3) The other items were relatively stable (i.e., showed less fluctuation), although many of them showed an upward shift. 4) Some of the control survey programs yielded biased evaluation results. Thus, the SDI chart method proved to allow, as one of the external quality control techniques, observation of long-term, slight changes without necessitating any complicated calculation. Furthermore, it was confirmed that this is a practically useful method of accuracy evaluation because it allows overall evaluation of the data from various control survey programs on the same graph.
- 東海大学の論文
著者
-
Niwa Masaharu
Department Of Clinical Pathology School Of Medicine Tokai University
-
Nishino Harumi
Central Clinical Laboratory Tokai University Hospital
-
Miyamoto Motoaki
Central Clinical Laboratory Tokai University Hospital
-
Miyamoto Motoaki
Central Cilinical Laboratory Tokai University Hospital
関連論文
- Quantitative Thin-Layer Chromatography with a Flame Ionization Detector for Serum Lipid Measurements in the Routine Clinical Laboratory
- A Case of Acute Myeloblastic Leukemia with Chromosomes Showing 46, XY=11/46, XY, 21q-=39
- A Variant Translocation (11; 22) (p15; q11) in a Patient with Chronic Myelocytic Leukemia
- Interpretation of Pathophysiology by Laboratory Data (3) A Consultation Program Based on Clinical Laboratory Data
- Studies on the Rapid Determination of Glucose Level in Blood Using the Enzyme Electrode, the "Glucose Meter"
- Evaluation of an Automated Differential Leukocyte Counting System "Hematrak"
- Study on Erythrocyte Lipids and Osmotic Fragility in Elderly People with Anemia
- The Current Concepts of "Normal Values" and "Clinical Reference Values" in the Clinical Laboratory : Trials for Determining Clinical Reference Values of the Tokai University Hospital
- Drug-Induced False Positive Tests for Protein in Urine Specimens from the Automated Multiphasic Health Testing Services of Tokai University Hospital
- Standard-Deviation-Index-Pattern Analysis of Blood Chemical Data in Health Check-Ups for Chronic Liver Disease : A Clinico-Pathological Study
- A Case with Silent Type of Pseudo-Acholinesterasemia
- Plasma Antithrombin III, _-Plasmin Inhibitor and Plasminogen Activities in Cases of Various Liver Diseases
- Study of Urinary Specific Gravity by Reagent Strip Method
- Interpretaion of Patho-physiology by Laboratory Data (4) Cases of Hypernutritional Fatty Liver
- Interpretation of Pathophysiology by Laboratory Data (1) Graphic Display of Data, Static Pattern
- A Practical Evaluation of Accuracy with the Standard Deviation Index (SDI) Chart Method Second Report : Report Covering the Period from April 1980 to March 1983
- Delta Check System for Detection and Further Management of Laboratory Errors : Second Report. Computer Program to Identify Laboratory Errors
- Delta Check System for Detection and Further Management of Laboratory Errors : First Report Graphical Presentation of Results
- Interpretation of Pathophysiology by Laboratory Data (2) Graphic Display of Data, Dynamic Pattern