Accuracy Evaluation in the Measurement of a Small Change in the Thickness of Arterial Walls and the Measurement of Elasticity of the Human Carotid Artery
スポンサーリンク
概要
- 論文の詳細を見る
For the diagnosis of the early stages of atherosclerosis, it is important to evaluate the local acoustic characteristics of the arterial wall. For this purpose, it is necessary to increase the spatial resolution in the axial direction to several millimeters, which corresponds to the size of the macular lesion on the surface of the wall. We have proposed a method for measuring small velocity signals on the intima and adventitia of the arterial wall from the skin surface using pulsive ultrasonic waves. The small change in thickness of the arterial wall is obtained by integrating the difference between the two velocity signals on the intima and adventitia. The elastic property of the arterial wall is noninvasively evaluated from the change in thickness and the arterial inner pressure. In this paper, we evaluate the accuracy of the proposed method for measuring the small displacement. Moreover, we applied this method to evaluate the elastic property of the arterial wall of 50 patients and 8 healthy subjects.
- 社団法人応用物理学会の論文
- 1998-05-30
著者
-
KANAI Hiroshi
Graduate School of Engineering, Tohoku University
-
HASEGAWA Hideyuki
Graduate School of Engineering, Tohoku University
-
Koiwa Yoshiro
First department of Internal Medicine, Tohoku University School of Medicine
-
Koiwa Yoshiro
First Department Of Internal Medicine School Of Medicine Tohoku University
-
HOSHIMIYA Nozomu
Department of Electronic Engineering, Tohoku University Graduate School of Engineering
-
CHUBACHI Noriyoshi
Faculty of Engineering, Tohoku Gakuin University
-
Chubachi Noriyoshi
Tohoku Gakuin Univ.
-
Hoshimiya Nozomu
Department Of Electronic Engineering Tohoku University Graduate School Of Engineering
-
Hoshimiya Nozomu
Graduate School Of Engineering Tohoku University
-
Kanai Hiroshi
Graduate School Of Engineering Tohoku University
-
Hasegawa Hideyuki
Graduate School Of Engineering Tohoku University
-
Koiwa Yoshio
1st Dept. Of Intern. Med. Tohoku Univ.
-
Chubachi N
Faculty Of Engineering Tohoku Gakuin University
-
Chubachi Noriyoshi
Faculty Of Engineering Tohoku Gakuin University
-
Kanai Hiroshi
Graduate School Of Biomedical Engineering Tohoku University
-
Hasegawa Hideyuki
Graduate School Of Biomedical Engineering Tohoku University
関連論文
- 血管壁硬さ分布の経皮的評価法と電子染色
- 病理標本との対応に基づいた動脈壁組織の弾性率の超音波計測
- SA-5-4 超音波による動脈壁の局所弾性特性の計測とイメージング : 病理との対照実験
- 超音波による動脈壁弾性特性の空間分布計測
- 頚動脈弾性特性の生活習慣病での測定の意義
- 頚動脈壁弾性率計測を用いた喫煙による早期動脈硬化病変の検出
- 動脈血管壁内弾性率分布のリアルタイム計測システムの開発
- PH8 右室自由壁・中隔壁・左室自由壁の運動速度と厚み変化の計測(医用超音波,ポスターセッション2)
- 高精度超音波測定による微小心筋機能計測法
- 0137 心不全における心筋壁内各層の収縮性の不均一性の重要性
- 微小振動解析法によるadriamycin心毒性の定量的診断
- Impact of Lifestyle-Related Diseases on Carotid Arterial Wall Elasticity as Evaluated by an Ultrasonic Phased-Tracking Method in Japanese Subjects
- Evaluation of Plaque Stabilization by Fluvastatin with Carotid Intima-Medial Elasticity Measured by a Transcutaneous Ultrasonic-Based Tissue Characterization System
- PJ-302 High-Resolution Measurement of Carotid Artery Wall Elasticity for Clinical Tailor-Made Risk Management of Arteriosclerosis(Atherosclerosis, clinical-09, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- Usefulness of measurement of carotid arterial wall elasticity distribution in detection of early-stage atherosclerotic lesions caused by cigarette smoking
- PE-166 Influence of Cardiovascular Risk Factors on Carotid Arterial Elasticity Measured by the Transcutaneous Ultrasonography Using Phased-tracking Method(Atherosclerosis, clinical-7 (H) PE28,Poster Session (English),The 70th Anniversary Annual Scientific
- Incidence and Characteristics of Ventricular Fibrillation in Bystander-witnessed Out-of-hospital Cardiac Arrest with Cardiac Etiology in the City of Sendai, Japan
- 動脈硬化症における壁内組成異常計測の臨床的意義 : 2. IMT正常例での動脈壁内組成の変化(第140回日本循環器学会東北地方会)
- 動脈硬化症における壁内組成異常計測の臨床的意義 : 1. 臨床機器の開発と計測値の信頼性(第140回日本循環器学会東北地方会)
- Estimated Incidence of Ventricular Tachycardia/Fibrillation (VT/VF) in out-of Hospital Cardiac Arrest (OHCA) with Cardiac Etiologies (Preventive Medicine/Epidemiology/Education/Health Policy 5 (H), The 69th Annual Scientific Meeting of the Japanese Circul
- Incidence of Ventricular Fibrillation in out-of Hospital Cardiac Arrest (OHCA) Depends on Age and Time of Day (Preventive Medicine/Epidemiology/Education/Health Policy 5 (H), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- Systolic Blood Pressure Triggers the Athero-Arteriosclerotic Process in Coronary Artery Disease-Study Adopting High Resolution Doppler Measurement(Echo/Doppler 4 (I), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- Imaging of Takayasu Arteritis with the Phased Tracking Method(Echo/Doppler 2 (I), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- Transmural Myocardial Function to Evaluate the Reversibility of Anthrocycline Cardiotoxicity(Heart Failure, Clinical 17 (M), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- Poor Prognosis of Japanese Patients With Chronic Heart Failure Following Myocardial Infarction : Comparison With Nonischemic Cardiomyopathy
- Analysis of Chronic Heart Failure Registry in the Tohoku District : Third Year Follow-up
- P856 動脈硬化ことに動脈壁の弾性異常に対する生活習慣是正の重要性
- 0534 肥大型心筋症における拡張障害と心筋内各層の機能的不均一性の定量的関係 : 新しい高精度ドプラ法(位相差トラッキング法)による検討
- 心筋の局所厚み変化の非侵襲的計測による心筋障害の評価
- 55) アドリアマイシン心筋症における心筋障害に対する高精度超音波ドプラ法の有用性 : 1995年から1999年まで
- 20)高精度ドプラ法による心筋内層別機能と病理組織変化
- 動脈硬化危険因子是正効果は壁弾性測定により最も鋭敏に把握しうる : 集団検診における、新しい超音波ドプラ法による頚動脈壁弾性値の高精度計測
- P793 高精度超音波ドプラ法による頚動脈壁弾性値と動脈硬化危険因子の関係 : subclinicalな状態でも危険因子の是正は壁弾性を改善する
- 23)新しい超音波ドプラ法によるアテローム内部組成把握
- P407 非侵襲的に心筋内部各層の組織学的変化を推定しうるか〜高精度超音波ドプラ法によるAnthracycline(Anth)投与モデルでの検討
- P277 高精度超音波測定による頚動脈内粥腫病変の内部組成探査〜粥腫の易破裂性評価は可能か
- P273 有意な粥腫病変を見ない"正常者"においても、動脈硬化危険因子に応じて、動脈壁自体の固有弾性率の異常増大が見られる : 新しい超音波ドプラによる高精度計測
- 心筋の収縮弛緩特性の非侵襲的評価と病理所見との比較
- プラーク内組成の新しい非観血的高精度測定法によるプラーク形成から破綻への評価への可能性
- PG-12 血管拡張薬に対する動脈壁厚み変化の過渡応答の超音波による高精度計測
- Relationship between upper limb peripheral artery stiffness using the radial artery and atherosclerotic parameters
- PE-368 Diabetes Mellitus and Smoking Play More Important Role Than Hypertension and Hyperlipidemia in Determining Elasticity of the Carotid Artery Intima-media(Echo/Doppler-9 (I) PE62,Poster Session (English),The 70th Anniversary Annual Scientific Meeting
- 頚動脈壁弾性率計測を用いた喫煙による早期動脈硬化病変の検出
- 動脈血管壁内弾性率分布のリアルタイム計測システムの開発
- 血管壁組織性状診断・治療システム
- 超音波による心筋の局所厚み変化の非侵襲的評価と病理所見との定量的比較
- IS083 Mechanism of coronary flow modulation at phase-controlled vibration in open chest canine preparation
- DIASTOLIC MECHANICAL VIBRATION INCREASE CORONARY BLOOD FLOW IN CANINE HEART WITH REGIONAL ISCHEMIA
- Ventricular Contractility Evaluated by Mechanical Perturbation of the Myocardium : Experimental and clinical approach adopting small amplitude vibration input : CLINICAL EVALUATION OF CARDIAC PERFORMANCE
- P2-45 超音波診断のための心筋伸縮時の振動の計測と解析(ポスターセッション2,ポスター発表)
- 心臓壁からの超音波後方散乱強度の一心周期内での短周期変動の計測
- 超音波で計測した心臓壁微小振動の解析による左室拡張末期圧と心筋弾性値の非侵襲的計測
- Tissue structure of arterial wall revealed with elasticity imaging
- Construction of Reference Data for Tissue Characterization of Arterial Wall Based on Elasticity Images
- Evaluating the regional elastic modulus of a cylindrical shell with nonuniform wall thickness
- A Noncontact Thickness Measurement of Thin Samples Using 40 kHz Ultrasonic Wave
- A technique of measuring relative sound velocity changes using a frequency variable type ultrasonic correlation system
- Measurement of Ultrasonic Velocity in Liquid Using a Modified Ultrasonic Correlation System Under Low S/N Condition : Acoustical Measurements and Instrumentation
- Velocity Measurement in Liquids by using Reflection Type Ultrasonic Correlator via Wave number Analysis in MHz Range : Physical Acoustics
- Cross-Sectional Elasticity Imaging of Arterial Wall by Comparing Measured Change in Thickness with Model Waveform
- Measurement of Elastic Moduli of the Arterial Wall at Multiple Frequencies by Remote Actuation for Assessment of Viscoelasticity
- Analysis of Acoustic Fields from Acoustic Convex Lens
- P2-C-8 Control of Acoustic Fields Using Acoustic Convex Lens
- P2-23 Beam Width Controllable Ultrasonic Transducer Array
- In vivo Measurement Method for Nonlinearity Parameters Using Single Ultrasonic Transducer (Short Note)
- P2-14 In vivo Measurement Method of Nonlinearity Parameter Using Single Ultrasonic Transducer
- Design of the Double Ultrasonic Transducer for Nonlinearity Measurement of Acoustic Waves
- Measurement and Analysis of Vibrations on Surface of Phantom Induced by Piezoelectric Extracorporeal Shock Wave Lithotripter
- Power Difference in Spectrum of Sound Radiation before and after Break of Phantom by Piezoelectric Extracorporeal Shock Wave Lithotriptor
- Beam-Width-Controllable Ultrasonic Transducer Array
- PARCORR-Based Time-Dependent AR Spectrum Estimation of Heart Wall Vibrations (Special Section on Advanced Signal Processing Techniques for Analysis of Acoustical and Vibrational Signals)
- Measurement and analysis of vibration in the myocardium telescopic motion for novel echo-graphic diagnosis
- A new method to measure bone properties by means of leaky surface acoustic waves
- Frequency Analysis of Strain of Cylindrical Shell for Assessment of Viscosity
- Ultrasonic Measurement of Minute Displacement of Object Cyclically Actuated by Acoustic Radiation Force
- Measurement of Change in Wall Thickness of Cylindrical Shell Due to Cyclic Remote Actuation for Assessment of Viscoelasticity of Arterial Wall
- Cross-Sectional Elasticity Imaging of Carotid Arterial Wall in Short-Axis Plane by Transcutaneous Ultrasound
- Estimation of the Location of Intracranial Vascular Diseases Using Several Sensors
- Tissue Characterization of Atherosclerotic Plaque by Ultrasonic Measurement of Regional Elasticity
- Ultrasonic Measurement of Regional Elasticity of Arterial Wall for Evaluation of Vulnerability of Atherosclerotic Plaque
- Cross-Sectional Elastic Imaging of Arterial Wall Using Intravascular Ultrasonography
- Ultrasonic Transducer Composed of Two Piezoelectric Layers with Variable Weighting : Ultrasonic Transduction
- Fracture Mechanics Evaluation of Acoustic Fatigue in Piezoelectric Ceramics : A: APPLICATIONS AND FUNDAMENTALS
- Cycle-to-Cycle Control of Swing Phase of FES-induced Hemiplegic Gait : A Computer Simulation with Different Controllers
- Electromyographic Study Relating to Shoulder Motion : Control of Shoulder Joint by Functional Electrical Stimulation
- Restoration of Shoulder Movement in Quadriplegic and Hemiplegic Patients by Functional Electrical Stimulation Using Percutaneous Multiple Electrodes
- Reduction of Influence of Decrease in Signal-to-Noise Ratio in Measurement of Change in Thickness of Arterial Wall Due to Heartbeat
- Accuracy Evaluation in the Measurement of a Small Change in the Thickness of Arterial Walls and the Measurement of Elasticity of the Human Carotid Artery
- Dependence of Elastic Modulus on Inner Pressure of Tube Wall Estimated from Measured Pulse Wave Velocity
- A Method of Multichannel PID Control of 2-Degree of Freedom of Wrist Joint Movements by Functional Electrical Stimulation
- Simultaneous Measurement of Vibrations on Arterial Wall Upstream and Downstream of Arteriostenosis Lesion and Their Analysis
- Non-Contact Simultaneous Measurement of Thickness and Acoustic Properties of a Biological Tissue Using Focused Wave in a Scanning Acoustic Microscope : Medical Ultrasonics and Ultrasonic Measurements
- Propagation Properties of Ultrasound in Acoustic Microscopy through a Double-Layered Specimen Consisting of Thin Biological Tissue and Its Holder : Ultrasonic Imaging and Microscopy
- A Basic Study on Control Command Input Device Using Head Movement for FES System : Availability of Acceleration Sensors(Papers Selected from 2003 International Technical Conference on Circuits/Systems, Computers and Communications(ITC-CSC
- Scanning Acoustic Microscope Employing Concave Ultrasonic Transducers : Physical Acoustics I
- Analog LSI Neuron Model Inspired by Biological Excitable Membrane
- In Vivo Measurement of Small Velocity Signals and Change in Thickness of the Heart Walls
- Non-regularity in muscle fiber stimulation pulses creates higher levels of force : a simulation study
- Measurement of displacement and strain in biological tissue generated by ultrasonic dual acoustic radiation force
- ST segment changes under occlusion of the proximal portion of major coronary arteries in the isolated canine heart.