A Method for Evaluating the Cavity Loss and an Optimum Reflectivity of the Output Mirror in a Ruby Laser with an External Mirror
スポンサーリンク
概要
- 論文の詳細を見る
Both the cavity loss and an optimum reflectivity of the output mirror were determined experimentally from a set of measurements of the laser energy output for different glass plates placed as attenuators inside the cavity. The internal cavity loss value and the optimum value of the reflectivity for the ruby used were 0.14±0.01 per pass and 0.73, respectively under the pumping of 1000 joules, with mirror spacing of 23.6 cm, and at fixed temperature of 13℃. This optimum reflectivity was in good agreement with the one obtained by the measurements of the energy output for different reflectivities of the output mirror.
- 社団法人応用物理学会の論文
- 1966-01-15
著者
-
Ohtsuka Yoshihiro
Department Of Applied Physics Faculty Of Engineering Osaka University
-
Ohtsuka Yoshihiro
Department Of Applied Physics Faculty Of Engineering Hokkaido University
関連論文
- A CO_2 Q-Switched Laser and Its Nonlinear Amplification Characteristics
- Optical Heterodyne Simulation-Experiments on First-Order Correlation Measurements of Fluctuating Laser Beam
- Effects of Spatial Coherence and Dispersive Diffraction on Spectral Changes
- Resolution of a Double-Slit Object Illuminated with Ultrasound-Modulated Laser Light
- Dynamic Photoelastic Analysis by Optical Heterodyne Polarimetry
- Experiments on Noncritical Optical-Heterodyning Using Two Successive Ultrasonic Light Modulators
- Mode Degeneracy-Dips on Output of Gaslaser
- Correlation-induced Spectral Changes Dependent upon Spatiotemporal Interference Effects
- Effects of Spatial Coherence and Dispersive Diffraction on a Change in Optical Spectrum
- Annular Output Coupling for Infrared Gas-Laser
- A Q-Switched CO_2 Laser with Absorbing Gas in the Laser Cavity
- Laser Doppler Differential System for Three-Dimensional Vector Velocimeter
- Three-Dimensional Laser Doppler Scalar Velocimeters with Directional Non-Ambiguity
- A Method for Evaluating the Cavity Loss and an Optimum Reflectivity of the Output Mirror in a Ruby Laser with an External Mirror
- Laser Heterodyne Measurements of Extremely Low Velocities of Moving Bodies : Doppler Velocimetry
- Optical Coherence Reduction by an Amplitude-Modulated Ultrasonic Wave
- Nonlinear Infrared Transmission in Gaseous SF_6 Induced by Q-Switched CO_2 Laser Radiation at 10.6μm
- Temperature-Disturbance Free Magnetic Field Sensor Based on Double Fiber Optic Polarimetry
- Birefringent Side-Hole Fiber for Use in Strain Sensor
- Optical Heterodyne Impulse-Response Measurement of Lithium Tantalate Phase Modulator Driven by Wideband Frequency Signal
- White-Light Frequency-Domain Interferometry Using a Kosters Prism
- Optical Heterodyning with Noncritical Angular Alignment Using a Pair of Ultrasonic Light Modulators
- Optical Transmission in an Excited Two-Level Medium
- Proposal of a Resonator for Far Infrared Laser on Molecular Rotational Transitions Using Q-Switching Technique
- Highly Sensitive and Widely Dynamic Fiber-Coiled Deformation Sensor Immune from External Disturbances
- 逆フーリエ分光法に基づいた複屈折単一モード光ファイバの圧力誘起結合モード測定とそのセンシングへの応用
- Is the Van Cittert-Zernike Theorem Applicable to Spatially Incoherent Broadband Spectral Source?
- Spectrum Invariance for a Particular Class of Optical Fields Propagated in Far Zone