Determination of Random Component in Delayed Coincidence Spectroscopy
スポンサーリンク
概要
- 論文の詳細を見る
In order to determine a spectral line-width with a delayed coincidence spectrometer, the random component must be measured accurately. For this purpose, the mean frequency method is investigated. The random component measured by this method is equal to the product of the gate time of counting and the mean square frequency of input pulses. In this method, the gate time of the spectrometer must be set accurately and, therefore, is determined by a digital circuit. The mean frequency method is employed for the measurement of scattered light. It is found that the bunching component can be determined in detail and that the spectral line-width of a single Gaussian light can be measured accurately and promptly.
- 社団法人応用物理学会の論文
- 1974-04-05
著者
-
Suzuki Norihito
Department Of Applied Physics Osaka University
-
Kikkawa Atsushi
Department Of Applied Physics Faculty Of Engineering Osaka University
-
Kikkawa Atsushi
Department Of Applied Physics Osaka University
-
Yoshimura Takeaki
Department Of Applied Physics Faculty Of Engineering Osaka University
-
Suzuki Norihito
Department Of Anesthesiology Nippon Medical School
-
SUZUKI Norihito
Department of Applied Physics, Faculty of Engineering Osaka University
関連論文
- BCD-02 INITIATION OF SURFACE CRACK IN CVT RUBBER BELTS(BELT AND CHAIN DRIVES)
- Role of Helicobacter pylori infection and nonsteroidal anti-inflammatory drug use in bleeding peptic ulcers in Japan
- Endoscopic injection sclerotherapy for esophageal varices in cirrhotic patients without hepatocellular carcinoma : a comparison of longterm survival between prophylactic therapy and emergency therapy
- Characteristics of gastroesophageal reflux disease in Japan : increased prevalence in elderly women
- Photoelectron Counting Statistics of Light Transmitted through Multimode Optical Fiber
- Photoelectron Counting Statistics of Laser Light Scattered by Very Dilute Solution
- Characteristics of Weight Function in a Steady-state Diffusion Optical Tomography
- Range Technique in Scattering Medium Using a Needle-Fiber Optical Coherence Tomography System
- Effects of propofol anesthesia on cognitive recovery of patients undergoing electroconvulsive therapy
- News production technology applies High-Definition 3D virtual studio system ((放送方式、放送現業、無線・光伝送)2000 Asia-Pacific Symposium on Broadcasting and Communications)
- Spectroscopy of Laser Scattered Light by Eye Lens
- A 1024-Channel Digital Apparatus for Measurements of the Time Interval Distribution
- Accurate Stabilization of a 3mW Single-Mode Output He-Ne Laser by Intermittent Frequency Offset Locking to an Iodine Stabilized He-Ne Laser
- Intermittent Frequency Offset Lock of a Symmetric Three-Mode Stabilized He-Ne Laser to an Iodine Stabilized He-Ne Laser
- An Intermittent Frequency Offset Lock of a Transverse Zeeman Laser to an Iodine Stabilized He-Ne Laser
- Measurements of Electrophoretic Movements with an Optical Beating Spectrometer
- Spectral Linewidth and Time Interval Distribution of Photoelectric Pulses : Spectroscopy
- A Delayed Coincidence Spectrometer and Spectral Line Profiles of Scattered Lights
- Statistical Properties of Gaussian-Lorentzian Light and Dead Time Loss of Photon-Counting System
- Determination of Random Component in Delayed Coincidence Spectroscopy
- Dead-Time Losses of Multichannelized Delayed Coincidence Spectrometer
- Spectroscopy of Light Scattered by Suspended Charged Particles
- A Differential Scanning Fabry-Perot Interferometer
- Brillouin Scattering of KCl-KBr Mixed Crystals
- Topographic Analysis of Ocular Fundus Using the Fourier Transform Method for Projected Grating Images
- Measurement of Particle Velocity Using a Time Interval Distribution of Photoelectric Pulses
- A Multi-Beam Interferometer and Its Use as a Screening System in Gynecologie Cytology
- A Simple Frequency Lock of Green YAG Laser to Dispersion Line of the linear Absorption Spectrum of Iodine Molecules Utilizing an Acousto-Optic Frequency Shifter
- Nonlinear Infrared Transmission in Gaseous SF_6 Induced by Q-Switched CO_2 Laser Radiation at 10.6μm
- A Derivative Mossbauer Spectrometer Stabilized by Digital Method
- Pre-filtering Effect in an Iterative Deconvolution Method and Its Application to Signal Recovery in Fiber-Optic Distributed Temperature Sensors
- Imaging a Reflecting Plate Located in Scattering Media Using Optical Frequency Domain Reflectometry
- A Digital Full-Autocorrelator for Photoelectric Pulses
- Comparison of Multi-Beam and Single-Beam Cytofluorometers for an Automated Screening System in Gynecologic Cytology
- Factorial Moment of Two Poissonian Lights Superposed on Gaussian-Lorentzian Light
- Safety and efficacy of oral rehydration therapy until 2h before surgery : a multicenter randomized controlled trial
- Imaging Characteristics of Transmission-Type Volume Holographic Imaging Elements
- Full-Field Optical Coherence Tomography System with Controllable Longitudinal Resolution
- Optical Switching Elements Using Controllable Defect Modes in One-Dimensional Photonic Crystals