チタン合金を用いた広帯標準コンデンサ・マイクロホン
スポンサーリンク
概要
- 論文の詳細を見る
In this paper a study of wide-band high-reliability standard condenser microphone is described. Frequency band of the condenser microphone is limited by the first mode resonance frequency of the membrane and given by the following equation: f_1 = (α_1)/(2πa )√< T/ρ > where α_1 : eigen value for the first mode, a : radius of membrane, T : tension of membrane ρ: density of membrane To obtain the wide frequency band, it is necessary to use a membrane material having a large value of the ratio of ultimate tensile strength to density. As a result of the study about several kinds of materials, we found that titanium alloy( 2Al-2Mn-1Mo-95Ti ) is the most suitable one for the membrane material. This alloy is possible to roll up the thickness of 3μm, and after cold rolling an ultimate tensile strength of about 100 kg/mm^2 is obtainable. Density of the material is 4. 52g/cm^3. Furthermore, this material has a special feature that the instability due to the creep after tension is avoided by applying thermal aging 200°C for 5 hours similarly as in metallic titanium. This feature is shown in Figure3. Titanium alloy has sufficient values of Young's modules and hardness, so that it is also suitable as the body material of a condenser microphone. The structure of a newly designed standard condenser microphone named MR-112 is shoun in Figure 5. Tension of the membrance is impressed by a non-rotating ring, and structure contributes to the improvement of reliability. Pressure response of the microphone is shown in Figure8. Followings are the main characteristics of the condenser microphone of MR-112, i. e. , the response at 1 kHz is 54. 5 dB ( 0dB : 1 V/1 μbar ), the resonance frequency is 30 kHz, terminal electric capacitance is 22 pF, the equivalent air volume of membrane is 0. 01 cm^3, and the stability factor of membrane is 7. Value of the free field correction of the microphone used with a cylindrical head amplifier of semi-infinite length are shown in Figure 12. The condenser microphone of MR-112 has a high reliability as in MR-103, as well as wide band characteristics, then it is useful as a standard microphone, especially in the high frequency range.
- 社団法人日本音響学会の論文
- 1972-09-01
著者
関連論文
- 弾性表面波トランスジューサのパルス応答特性
- 直方体残響室における2点間音圧相関係数
- 弾性表面波チャープフィルタを用いたスペクトル分析回路
- 最大平坦な周波数温度特性をもつ弾性表面波発振器
- 同一の電極パタ-ンをもった複数個の弾性表面波共振器を用いた温度補償発振器
- 重み付け損失を軽減した弾性表面波フィルタ
- 線形計画法による弾性表面波フィルタの設計
- 線形計画法による弾性表面波フィルタの合成
- マイクロ波帯の超音波技術--弾性表面波素子の研究の動向
- 多重共振系の周波数特性の制御に関するモデル的考察
- 簡易無響室の吸音壁構造に関する検討
- ホノンエコー : 新しい音波物性とその応用I(連続3回)
- 標準マイクロホンの音圧校正における誤差
- 電気音響の現状と将来
- 密着露光法を用いたサブミクロン交さ指電極パタ-ン形成
- 多対ITDを用いた1端子対弾性表面波共振器とその狭帯域フィルタへの応用
- 多対IDTの結合モ-ド解析
- 多対IDTを用いた2端子対弾性表面波共振器
- 密着露光法を用いたサブミクロン電極の製作と1.1GHz発振の検討
- 位相符号形トランスジュ-サを用いた弾性表面波フィルタの設計
- 多対IDTを用いた弾性表面波共振器の解析とその応用
- 多対電極構成をもつ弾性表面波フィルタの設計
- 各研究分野15年の歩みと将来への展望 : 電気音響研究 (<小特集>創立40周年記念特集)
- 弾性表面波デバイスの挿入損失について : 近似式の適用限界
- チタン合金を用いた広帯標準コンデンサ・マイクロホン
- 音響機器用振動板の製作に対する電鋳法の応用について
- 電気音響変換のパラメータが複素領域で変化する場合の動作減衰量
- 応用面から見た弾性表面波素子
- 弾性表面波とその応用
- 金属製球殻を用いた音場測定用音源とその近接放射音場について