微小電極近傍での濃度勾配によるビーム偏向信号の測定
スポンサーリンク
概要
- 論文の詳細を見る
A measurement of the concentration gradient-induced optical beam deflection (OBD) in the vicinity of a microelectrode has been attempted. Platinum wires with diameters of 50 μm and 0.5 mm were used as a working microelectrode and a counter electrode, respectively. The reference electrode was a Ag/AgCl electrode. A ferricyanide/ferrocyanide redox reaction was used as a model electrochemical reaction. The applied potential of the Pt microelectrode was controlled using a polarographic analyzer. A probe beam from a diode laser was passed through the vicinity of the Pt microelectrode. Its deflection signal was detected by a position sensor consisting of a knife edge and a photodiode. Two kinds of potential sweeps were carried out. One was a potential step mode, the other was a triangle (cyclic voltammetry) one. Data for a simultaneous measurement of the current and OBD signals indicate that the present OBD method can be used for studying the concentration gradients in the vicinity of a microelectrode.
- 社団法人日本分析化学会の論文
- 1998-06-05
著者
-
呉 行正
福井大学大学院工学研究科材料開発工学専攻
-
呉 行正
福井大学工学部材料開発工学科
-
Wu Xing-zheng
Department Of Industrial Chemistry Faculty Of Technology Tokyo Metropolitan University
-
山口 守
福井大学工学部材料化学科
-
Wu X‐z
Fukui Univ. Fukui
-
永長 幸雄
福井大学工学部
-
永長 幸雄
福井大工
-
呉 行正
福井大学工学部
関連論文
- マイクロチップ電気泳動分析用の凸型鋳型ガラス基板の簡易作製
- ポリエステル繊維の難燃加工処理廃水中の難燃剤ヘキサブロモシクロドデカンのγ線照射分解
- Isoelectric Focusing Sample Injection for Capillary Zone Electrophoresis in a Fused Silica Capillary
- キャピラリー電気泳動分析の新規キャピラリー内濃縮法の開発
- キャピラリー電気泳動分析におけるオンライン濃縮
- キャピラリー等電点電気泳動分析の全カラムイメージング検出法の開発
- Several Factors Affecting the Detection Sensitivity of the Reaction Heat-Induced Optical Bean Deflection Method
- Detection Method Based on a Surface Plasmon Resonance and Its Application to Flow Injection Analysis and Liquid Chromatography
- キャピラリー電気泳動分析のための電気浸透流による試料の吸引注入法
- γ線による水中重金属イオンの還元と除去
- 酢酸エチル抽出/微分パルスポーラログラフィーによるセレン(IV)及びテルル(IV)の高感度定量(超微量分析のための前処理と予備濃縮)
- 微小電極近傍での濃度勾配によるビーム偏向信号の測定
- Reduction of Carbon Dioxide in γRay Irradiated Carbon Dioxide : Water System Containing Cu^ and SO_3^
- γ線による水中重金属イオンの還元と除去
- 熱のビーム偏向測定法による化学反応計測
- Time-resolved Chemiluminescence Study of Photocatalytic Reaction of TiO_2
- 環境負荷化合物の分解・除去における放射線の利用
- Capillary Electrophoresis of Small Anions in Complex Samples with a Hollow Fiber Sampling Inlet End
- 微小電極での電気化学反応のビーム偏向法による検討
- Lyoluminescence及びそれを利用する新規分析法
- 光開始化学発光系の時間分解化学発光測定
- 反応熱によるプローブ光の偏向を利用する新規化学計測法(関東支部創立40周年記念)
- 半導体光触媒による有機過酸化物生成を利用する鉄(II)の選択的化学発光分析
- Time-Resolved Chemiluminescence of Luminol Induced by TiO_2 Photocatalytic Reactions
- 反応速度の差を利用するチタン(IV)とバナジウム(V)の同時吸光光度定量
- Radiolytic Degradation of Chlorinated Hydrocarbons in Water
- An Improvement of the On-line Electrophoretic Concentration Method for Capillary Electrophoresis of Proteins and Experimental Factors Affecting the Concentration Effect
- 炭酸プロピレン抽出/微分パルスポーラログラフィーによる銅(II)の簡易定量
- ガスかき混ぜ溶媒抽出分離/微分パルスポーラログラフィーによる生体物質中の銅及び鉄の同時定量(バイオアナリティカルケミストリー)
- A Simple Transmitted Interference Method for Nanovolume Detection
- Chemiluminescence on a Microchip
- カーバイド滓を用いた重金属汚染土の不溶化