Dependence for Loss Cone on Accelerating Potentials and Injection Angles of Electrons in Magnetic Mirror Fields
スポンサーリンク
概要
- 論文の詳細を見る
In this paper the electrons, which wese cotinuously injected into the magnetic mirror field, escaping along the magnetic field lines are studied by varying the following parameters; 1) Mirror ratio of the magnetic mirror field from the value of 3.7 to 7.2; 2) Accelerating potential of the electrons from the value of 1.5 kV to 2.5kV; 3) Injection angle of the electrons from the value of 20°to 120°. In spite of variety of the accelerating potentials and the injection angles the ratio of escaping electrons to injected electrons along the magnetic field lines is keeping constant and there is no dependence on the mirror ratio which determines a loss cone in the velocity space. Thus, in the magnetic mirror field, it will be considered that for the continuous injection of electrons a probability of electrons entering the loss cone is the same causing of scattering by the neutral particles.
- 東海大学の論文
- 1971-03-31
著者
関連論文
- Spectroscopic Measurements of Ion Temperature in Sheet Plasma and String Plasma
- Performance Comparison of Real-Time Laser Absorption Spectrometers for NH_3 Detection at 1.54 and 3.03μm in a H_2O Vapor Mixture
- Measurements of NO_2 Concentration with Wide Dynamic Range Based on Laser Absorption Spectroscopy Using a Multi-Pass Optical Cell : Effects of Ambient Temperature Change at the Optical Cell
- Trace Methane Detection Based on Raman Spectroscopy Using a High Finesse Optical Resonator
- Performance Characteristics of Power Build-Up Cavity for Raman Spectroscopic Measurement
- Yb Fiber Laser Pumped Mid-IR Source Based on Difference Frequency Generation and Its Application to Ammonia Detection
- レーザー誘起蛍光法を用いた有機化学物質の検出
- Theoretical Analysis of a Radio Frequency Excited Slab CO_2 Laser
- Spatially Resolved Gain Measurements of a Slab Type RF Excited CO_2 Laser
- 安定共振器を伴った不安定共振器
- CO_2スラブ型レーザーの small signal gain 空間分布
- An Experimental Investigation of the Novel Unstable Resonator with a Stable Resonator Core
- 無電磁力・高βコイルの磁場強度の計算
- Interaction of a Steady Plasma Stream with a Rotating Dipole Magnetic Field
- Rotational Injection of the Plasma into the TBS Magnetic Field
- On the Region of Adiabatic Confinement of Plasma in the TBS Type Magnetic Field
- The Stability of the High-β Plasma in the TBS-Field about the Cusp-Axis
- Confinement of Plasma by Means of T. B. S. Type Magnetic Field
- Plasma Confined in the Minimum B Induced by Single Loop Current
- Development of a Mist Singlet Oxygen Generator
- 霧化型励起酸素発生器の基礎研究III
- Numerical Simulation of a Mist Singlet Oxygen Generator(Optics and Quantum Electronics)
- 霧化型励起酸素発生器の基礎研究II
- 霧化型励起酸素発生器の基礎研究
- Analysis of Heat Release from Gain Medium of Chemical Oxygen Iodine Laser
- Output Power Enhancement of a Chemical Oxygen-Iodine Laser by Predissociated Iodine Injection
- 化学酸素沃素レーザー(Chemical Oxygen Iodine Laser : COIL)の高圧力動作
- リチウムの同位体分離の為のプラズマ源
- レーザー オリジナル Development of a Nitrogen Dioxide Gas Sensor Based on Mid-Infrared Absorption Spectroscopy
- Design and Fabrication of Microlens Array for Near-Field Vertical Cavity Surface Emitting Laser Parallel Optical Head
- 光力システムにおける超音速化学励起沃素レーザーの新型 Jet type 励起酸素発生器の動作特性
- イオンサイクロトロン共鳴法を用いたリチウムの同位体分離
- The Unstable Resonant with a Stable Resonator Core
- Dependence for Loss Cone on Accelerating Potentials and Injection Angles of Electrons in Magnetic Mirror Fields
- Simple Real Time Trace Nitrogen Dioxide Detector Based on Continuous-Wave Cavity Ringdown Spectroscopy Using Passively Locked External Cavity Diode Laser
- Removal of Water Vapor in a Mist Singlet Oxygen Generator for Chemical Oxygen Iodine Laser
- High-Pressure Nozzle Bank for a Chemical Oxygen Iodine Laser
- Yb Fiber Laser Pumped Mid-IR Source Based on Difference Frequency Generation and Its Application to Ammonia Detection
- Parametric Studies on Improved Laser Cutting Performance of Magnesium Alloy with Two Flow Nozzles
- Performance Characteristics of Narrow Linewidth Fiber Laser Pumped Mid-IR Difference Frequency Mixing Light Source for Methane Detection
- Spatially Resolved Gain Measurements of a Slab Type RF Excited CO2 Laser