電解水による歯科用器具の消毒とその腐食傾向
スポンサーリンク
概要
- 論文の詳細を見る
The excellent bactericidal activity of the electrolyzed acid water has recently been noticed in dentistry. The authors previously demonstrated the validity of the strong acid water as a disinfectant for impression showing rapid and reliable sterilization effect. In the present study, the applicability of the electrolyzed water to sterilization of dental metallic instruments was examined. The contamination bacteria tested were Streptococcus salivarius (IFO 13956). As the problem with the acid water is that it is potentially corrosive to metals, corrosion tests were also carried out. The instruments having simple configuration such as reamer and explorer could be sterilized by one-minute immersion in the strong acid water, while those of comlicated configuration such as diamond stones and burs required much longer time for equivalent sterilization. When the ultrasonic cleaning action was added in the strong acid water, all the instruments were sufficiently sterilized by one-minute treatment although such a cleaning itself could give little effect of removing bacteria from the instruments even by 20-minute treatment in distilled water. Another type of electrolized water, the week acid water 5.2 in pH showed almost the same effects as the strong acid water. The reamer and diamond stone showed no corrosion in 24-hour immersion in the acid water. The working end of the explorer was also sound while many corrosion pits were observed on its handle. A marked corrosion was found on the overall surface of the steel burs, and a localized loss occurred at the brazed area between the blade and shank of the carbide burs without the blade being harmed. It was confirmed that the week acid water was less corrosive than the strong. Significant damages of the burs by corrosion appeared after 3-hour immersion in the acid water. The term corresponds to 180-time repetitions of one-minute immersion treatment, indicating that such a corrosion behavior may not result in any practically serious problem because it may far exceed the mechanical lives in service of their blades. These findings suggest that both the electrolyzed strong and week acid waters may well be available as the disinfectant for dental instruments.
- 九州歯科学会の論文
- 1997-12-25
著者
-
田島 清司
九州歯科大学歯科理工学講座
-
永松 有紀
九歯大・生体材料
-
永松 有紀
九州歯科大学口腔機能科学専攻口腔機能再建学講座生体材料学分野
-
田島 清司
九州歯科大学口腔機能科学専攻口腔機能再建学講座生体材料学分野
-
野正 久雄
九歯大・歯理工
-
野正 久雄
九州歯科大学歯科理工学講座
関連論文
- 繰り返し荷重によるセメント合着強さの変化
- カルボキシレートセメントの合着力におよぼす繰り返し荷重の影響
- リン酸塩系埋没材硬化時の発熱挙動とその影響 : 第 1 報 硬化時の温度変化
- 目視下鋳造での金銀パラジウム合金クラウンに及ぼす鋳造熟練度による鋳込み温度差の影響
- 接着性レジンセメントの接着強さに影響を及ぼす被着合金の機械的性質
- ヒトの歯に生じたくさび状欠損修復後の咬合により生じる特異応力場の強さ : コンポジットレジンの剛性の影響
- P-118 有歯下顎のCTデータに基づいた3-D FEモデリング(数値解析,一般講演(ポスター発表),第54回日本歯科理工学会学術講演会)
- P-115 電解中性水の根管洗浄における消毒効果(滅菌・消毒,一般講演(ポスター発表),第54回日本歯科理工学会学術講演会)
- P-114 再改良型電解中性水ジェルの保存安定性(滅菌・消毒,一般講演(ポスター発表),第54回日本歯科理工学会学術講演会)
- 電解中性水の根管洗浄への応用