A novel detection system for sub-harmonic components of ultrasonic pulse waves is constructed. A new double-layered piezoelectric transducer (DLPT), having the same polarization direction for each layer, is introduced to enhance the sensitivity for sub-harmonic components. In the case of DLPT stacked and bonded to one another in the same polarization direction, the resonance frequencies of the DLPT, $ f_{\text{r}}$, are $ f_{0}$ in a parallel connection and $ f_{0}/2$ in a series connection. As a result, the receiving sensitivity of the sub-harmonic components is increased by approximately 30 dB and the receiving sensitivity of fundamental components is decreased by approximately 20 dB, compared with those in the parallel connection. As an application of this system, the detection of sub-harmonic components generated from plastic-deformed metal rods is demonstrated. The DLPT system can be used to detect some deformed samples, while sub-harmonic components cannot be detected using a single transducer system.
- Published by the Japan Society of Applied Physics through the Institute of Pure and Applied Physicsの論文
- 2008-05-25
著者
-
Imano Kazuhiko
Department Of Electrical & Electronic Engineering Mining College Akita University
-
Nishihira Morimasa
Department Of Electrical And Electronic Engineering Faculty Of Engineering And Resource Science Akit
-
Fukuda Makoto
Department Of Applied Photonics System Technology
-
Imano Kazuhiko
Department of Electrical and Electronic Engineering, Faculty of Engineering and Resource Science, Akita University, Akita 010-8502, Japan
関連論文
- A Novel Double-Layered Piezoelectric Transducer for Detecting Second Harmonic Ultrasonic Pulse Waves
- Fully Hydrophobic Artificial Protein but Water Dispersible due to Large Dipole
- Submicrometer-Order Displacement Measurements Using an Air-Coupled Ultrasonic Transducer at Frequencies of 40 and 400kHz
- Generation of Monopole Ultrasonic Pulse from a Circular Source and It's On-axis Pressure Characteristics
- A technique of measuring relative sound velocity changes using a frequency variable type ultrasonic correlation system
- Experiments on Monopole Ultrasonic Pulse Radiated from Piezoelectric Polymer Film Transducers
- Measurement of Ultrasonic Velocity in Liquid Using a Modified Ultrasonic Correlation System Under Low S/N Condition : Acoustical Measurements and Instrumentation
- Velocity Measurement in Liquids by using Reflection Type Ultrasonic Correlator via Wave number Analysis in MHz Range : Physical Acoustics
- Measurement Method of Ultrasonic Velocity in Liquid and Solid Using Continuous Wave Signal
- Measurement of Micrometer Order Displacement Using Phase-Shift Type Ultrasonic Correlation System in MHz Range
- Simulation study of acoustic intermediate layer and electrical source impedance in an ultrasonic pulse system
- Experimental Determination of Piezoelectric Constants of Transversal Effects of Pb(Zr, Ti)O_3 (PZT) Transducer Using Transient Response (Short Note)
- Measurement of Ultrasonic Attenuation in Magnetic Fluid and its Application to Surface Profiling
- Detection of subharmonic components generated from microbubbles in water using double-layered piezoelectric transducer with aligning polarization directions
- An Irreducible Form of Gamma Matrices for HMDS Coefficients of the Heat Kernel in Higher Dimensions(Particles and Fields)
- Analyses of Resonances in 4- and 5-Neutrino Oscillations in Matter(Particles and Fields)
- A Study on the Conditions for Generation of Monopole Ultrasbnic Pulse by Piezoelectric Polymer Film Transducers
- Observation of the sound field in transient radiation from a concave piston source using time-transition pattern
- A method of observing the sound field in transient radiation from a piston source
- Development of a Detector of Variation of Underground Water Level Using Ultrasound : Acoustical Measurements and Instrumentation
- An Ultrasonic Displacement Measurement Method Using a Piezoelectric Device
- Measurement of Acoustic Properties of Magnetic Fluid and Its Application to Nondestructive Evaluation
- Real-Time Measurement of Acoustic Properties of Coating Material Using Surface Wave and Plate Wave
- Effects of fluid flow on elution of hydrophilic modifier from dialysis membrane surfaces
- MASS TRANSFER IN LAMINAR FLOWS AROUND SINGLE HOLLOW-FIBER MEMBRANES FOR HEMODIALYSIS
- Higher Plasma Vascular Endothelial Growth Factor Levels Correlate with Menopause, Overexpression of p53, and Recurrence of Breast Cancer
- An Evaluation of Predictive Factors Involved in Clinical or Pathological Response to Primary Chemotherapy in Advanced Breast Cancer
- Benefits of Medroxyprogesterone Acetate (MPA) in Advanced or Recurrent Breast Cancer with Higher Serum Concentration
- An Evaluation of DNA Polymerase α as a Prognostic Predictor in Early Breast Cancers Smaller than 2 cm
- Protonation-Induced Conformational Changes of N,N,N',N'-Tetramethylethylenediamine. Importance of Strong N-H^+…N Hydrogen Bonding
- Solid-State Dye Laser with Moire Gratings
- Spontaneous Assembly Formation of Cyclic Dimer of β-Amino Acid in Water
- Development of a device for chemiluminescence determination of superoxide generated inside a dialysis hollow-fiber membrane
- Laser Oscillation of Energy Transfer Solid-State Dye Laser with a Thin-Film Ring Resonator
- Characterization of Asymmetrical Molecular Orientation in Langmuir-Blodgett Films by the Stark Effect
- Perylene Orange Doped Acrylic Polymer for Solid-State Dye Laser : Optics and Quantum Electronics
- Analysis of the Laser Action of a Solid-State Dye Laser with a Thin Film Ring Resonator
- Detection of the second harmonics of Lamb waves in fatigued magnesium plates
- Microstructure Development in Neutron Irradiated Tungsten Alloys
- Viscosity Measurements in Liquid Using Transversal Effects of Piezoceramic Disk-Type PZT Transducer in the Frequency Range of 70-430 kHz
- White Emissions with Mixed Dyes
- Solid-State Dye Laser with Photo-Induced Distributed Feedback
- Experimental Study of Acoustic Properties of (0-3) Composite Materials for Intermediate Layer or Backing of Ultrasonic Transducers
- Experimental Study on Intermediate Layer Made of (0–3) Composite Materials for Use in Air-Coupled Ultrasonic Transducers
- Detection of Second-Harmonic Components of Lamb Waves Generated from Fatigue Plate Using a Double-Layered Piezoelectric Transducer
- Poly(N-vinyl-2-pyrrolidone) elution from polysulfone dialysis membranes by varying solvent and wall shear stress
- Low-Frequency Air-Coupled Ultrasonic System beyond Diffraction Limit Using Pinhole
- Nanometer-Order Resolution Displacement Measurement System by Air-Coupled Ultrasonic Wave Introducing Maximum Phase-Sensitivity Tuning
- Real Time Detection of Second-Harmonic Components Generated from Plastic-Deformed Metal Rod Using Double-Layered Piezoelectric Transducer
- Detection of Defects on Reverse Side of Metal Plate Using MHz-Range Air-Coupled Lamb Wave
- Novel Detection System Using Double-Layered Piezoelectric Transducer in Same Polarization Direction for Sub-Harmonic Components Generated from Plastic-Deformed Metal Rod
- Precise Displacement Measurements Using Phase Information of 40 kHz Ultrasonic Waves in Pinhole-Based Air-Coupled Ultrasonic System
- Real-Time Measurement of Acoustic Properties of Coating Material Using Surface Wave and Plate Wave
- Bend Stress Relaxation of Pure Tungsten
- Dual-Beam Distributed Feedback Solid-State Dye Laser with Photoresist Grating
- Effects of Re Content and Fabrication Process on Microstructural Changes and Hardening in Neutron Irradiated Tungsten
- Application of a Double-Layered Piezoelectric Transducer in the Generation of Short Ultrasonic Pulses
- Detecting pipe wall reduction using air-coupled MHz range ultrasonic wave
- Fabrication of Etchless Gratings for Distributed Feedback Solid-State Dye Lasers