Microcantilever-Based Biosensor for Detection of Various Biomolecules
スポンサーリンク
概要
- 論文の詳細を見る
We propose an optical and an electrical methods for detecting various biomolecules effectively with microcantilevers. The microcantilevers were fabricated employing surface micromachining technique that has attractive advantages in terms of cost efficiency, simplicity and ability of fabricating in array. The fluid cell system for injection of biomolecular solution is fabricated using poly(dimethylsiloxane) (PDMS) and a fused silica glass. The microcantilever is deflected with respect to the difference of the surface stress caused by the formation of self-assembled biomolecules on the gold coated side of the microcantilever. It detected cystamine dihydrochloride and glutaraldehyde molecules and analyzed individual concentrations of the cystamine dihydrochloride solution. We confirm that the deflections of bending-up or bending-down are occurred by the biomolecule adsorption and microcantilever can be widely used to a micro total analysis system ($\mu$-TAS) and a lab-on-a-chip for a potential detection of various biomolecules.
- 2006-01-15
著者
-
Kim Yong-sang
Department Of Electrical Engineering Myongji University
-
Kang C.
Department Of Materials Engineering Pusan National University
-
Nahm Baek-Hie
Department of bioscience and Bioinformatics and Nano-Bio Research Center, Myongji University, Gyeonggi 449-728, Korea
-
Yoo Kyung-Ah
Department of Electrical Engineering and Nano-Bio Research Center, Myongji University, Gyeonggi 449-728, Korea
-
Na Kwang-Ho
Department of Electrical Engineering and Nano-Bio Research Center, Myongji University, Gyeonggi 449-728, Korea
-
Joung Seung-Ryong
Department of Electrical Engineering and Nano-Bio Research Center, Myongji University, Gyeonggi 449-728, Korea
-
Kim Yong-Sang
Department of Electrical Engineering and Nano-Bio Reaserch Center, Myongji University, Gyeonggi 449-728, Korea
-
Kim Yong-Sang
Department of Electrical Engineering and Nano-Bio Research Center, Myongji University, Gyeonggi 449-728, Korea
関連論文
- Hydrogen Passivation on the Grain Boundary and Intragranular Defects in Various Polysilicon Thin-Film Taransistors
- Post-annealing Effects on the Characteristics of Poly-Si TFT's
- Post-annealing Effects on the Characteristics of Poly-Si TFT's
- Hydrogen Passivation on the Grain Boundary and Intragranular Defects in Various Polysilicon Thin Film Transistors
- Structural Dimension Effects of Plasma Hydrogenation on Low-Temperature Poly-Si Thin Film Transistors
- Characteristics of Two-Step Crystallized Polysilicon Thin-Film Transistors with a Novel Structure
- Bonding Phenomenon in Transient Liquid Phase Bonding of Ni Base Superalloy GTD-111
- Series DNA Amplification Using the Continuous-Flow Polymerase Chain Reaction Chip
- Dynamic Characteristics of the Micro-Fluidic Systems Actuated by Thermopneumatic-Method
- Microcantilever-Based Biosensor for Detection of Various Biomolecules
- Morphological Analysis of Cells by Scanning Electron Microscopy
- Electrical Properties of a Silicon Nanocrystal Embedded in a Thin Oxide Layer
- Characteristics of Two-Step Crystallized Polysilicon Thin-Film Transistors with a Novel Structure
- A Novel Electrochemical Detector using Prussian Blue Modified Indium Tin Oxide Electrode
- Electrostatic Force Microscopy of Metallic Ion-Intercalated DNA