Spot Scanning Using Radioactive 11C Beams for Heavy-Ion Radiotherapy
スポンサーリンク
概要
- 論文の詳細を見る
A scheme for spot scanning using 11C beams has been developed in order to form and verify a three-dimensionally conformal irradiation field for cancer radiotherapy. By selecting the momentum spread of a 11C beam, we could considerably decrease the distal falloff of the irradiation field, thus conserving the beam quality. To estimate and optimize the dose distribution in the irradiation field, it is essential to evaluate the precise dose distribution of spot beams. The coupling of the lateral dose and depth-dose distributions originating from a wide momentum spread should be taken into account to calculate the dose distribution of 11C beams. The reconstructed dose distribution of the irradiation field was in good agreement with the experimental results, i.e., within $\pm 0.2$%. An irradiation field of $35\times 35\times 43$ mm3 was optimized and spot scanning using 11C beams was carried out. The flatness was within $\pm 2.3$% with an error of 1% in the detector resolution.
- Publication Office, Japanese Journal of Applied Physics, Faculty of Science, University of Tokyoの論文
- 2001-04-15
著者
-
KITAGAWA Atsushi
National Institute of Radiological Sciences
-
FUTAMI Yasuyuki
National Inst. Radiological Sci.
-
Mizuno Hideyuki
Saitama Cancer Center
-
ISEKI Yasushi
Toshiba Co.
-
Iwashita Yoshihisa
Nuclear Science Research Facility, ICR, Kyoto University
-
Kanazawa Mitsutaka
National Institute of Radiological Sciences
-
Noda Koji
National Institute of Radiological Sciences
-
Urakabe Eriko
Nuclear Science Research Facility Icr Kyoto University
-
TOMITANI Takehiro
National Institute of Radiological Sciences
-
SUDA Mitsuru
National Institute of Radiological Sciences
-
SHIMBO Munefumi
National Cancer Center Hospital East
-
HIRATA Yoichi
Accelerator Engineering Corp.
-
Noda Akira
Nuclear Science Research Facility Icr Kyoto University
-
Kanai Tatsuaki
National Inst. Of Radiol. Sci
-
Urakabe Eriko
Nuclear Science Research Facility, ICR, Kyoto University, Gokanosho, Uji, Kyoto 611-0011, Japan
-
Kitagawa Atsushi
National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan
-
Suda Mitsuru
National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan
-
Iseki Yasushi
Toshiba Corp., Isogo Nuclear Engineering Center, 8 Shinsugita-cho, Isogo, Yokohama 235-8523, Japan
-
Hanawa Katsushi
Toshiba Corp., Isogo Nuclear Engineering Center, 8 Shinsugita-cho, Isogo, Yokohama 235-8523, Japan
-
Sato Kohsuke
Toshiba Corp., Isogo Nuclear Engineering Center, 8 Shinsugita-cho, Isogo, Yokohama 235-8523, Japan
-
Kanazawa Mitsutaka
National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan
-
Futami Yasuyuki
National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan
-
Mizuno Hideyuki
Saitama Cancer Center, 818 Komuro, Ina, Kita-Adachi, Saitama 362-0806, Japan
-
Shimbo Munefumi
National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba 277-8577, Japan
-
Kanai Tatsuaki
National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan
-
Iwashita Yoshihisa
Nuclear Science Research Facility, ICR, Kyoto University, Gokanosho, Uji, Kyoto 611-0011, Japan
-
Hirata Yoichi
Accelerator Engineering Corp., 2-13-1 Anagawa, Inage, Chiba 263-0043, Japan
-
Noda Koji
National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan
関連論文
- Mass Resolution for Iron Isotopes in CR-39 Track Detector
- Heavy ion CT system based on measurement of residual range distribution
- Heavy Ion CT Reconstructed from Residual Range Distribution Measured by Range Shifter and Fluoroscopy System
- Sensitometric Properties in Heavy Ion Radiography
- Experimental Study ot Heavy Ion Radialion using Monkcy and Phantom
- RBE and Dose Distribution of Heavy Ion Beams.
- Precise Measurement of Range of Heavy Charged Particles
- Dose response relations in acute cell death of pancreatic islet after whole body irradiatbn of gotlen harnster with gamma, proton and carton beams.
- Exploration of 'Over Kill Effect' of High-LET Ar-and Fe-ions by Evaluating the Fraction of Non-hit Cell and Interphase Death
- New Accelerator Facility for Carbon-Ion Cancer-Therapy
- Depth Encoding of Point-of-Interaction in Thick Scintillation Cameras
- Beam-Profile Control Using an Octupole Magnet
- Mutation induction on normal human cells by split dose irradiation with carbon-ion beams
- Cell death on human cells by split dose irradiation with carbonion beams.
- Correlation between cell death and induction of non-rejoining PCC breaks irradiated by accelerated carbon-ion beams and X rays
- Total Reaction Cross Sections of ^C on Plastic Scintillator in the Energy Range of 100-345 MeV/u(Cross-disciplinary Physics and Related Areas of Science and Technology)
- Heavy ion radiography
- A Pulse Stretcher by Slow Extraction Utilizing the Third-Order Resonance with the RF Knockout Method
- Spot Scanning Using Radioactive ^C Beams for Heavy-Ion Radiotherapy
- Development of multichanel Ion Chamber for measurement of 3 dimensional dose Distributions of Heavy-Ion Therapeutic Beam in patients
- Numerical Study on Range Measurement System with Positron Camera
- The Spot Scanning Irradiation with ^C Beams
- Morphological Evaiuation of Normal Tissue Damage after Carbon Beam Irradiation in Mouse Hind Legs
- Feedback Damping of a Coherent Instability at Small-Laser Equipped Storage Ring, S-LSR
- Irradiation System for HIMAC
- IONIZATION CROSS SECTION OF 390 MeV/u Ar^ IONS IN CARBON
- ATS Scattering from the Tetrahedral and Octahedral Site in Magnetite and Franklinite
- Effects of Carbon Beam on Survival and Hematopoietic System in Mice.
- Shielding and Microdosimetric Measurement of High Energy Neutrons and LET-dependence of TLD
- Prompt In-Line Diagnosis of Single Bunch Transverse Profiles and Energy Spectra for Laser-Accelerated Ions
- Improvement of Three-dimensional Monte Carlo Code PHITS for Heavy Ion Therapy
- Physical Evaluation of Multidetector-row Computed Tomography (MDCT) Scan Methods and Conditions for Improvement of Carbon Beam Distribution
- Effectiveness of Solid Dosimeters for Personal Dose Evaluation under Coexistence of Charged Particles
- Mass Resolution for Iron Isotopes in CR-39 Track Detector
- Analytical Design Method of Optimum Ridge Filters for Wobbled and Collimated Proton Beams
- Spot Scanning Using Radioactive 11C Beams for Heavy-Ion Radiotherapy
- Broadband Buncher Cavity for Beam Transport Line of HiECR Ion Source
- Feedback Damping of a Coherent Instability at Small-Laser Equipped Storage Ring, S-LSR