Feedback Damping of a Coherent Instability at Small-Laser Equipped Storage Ring, S-LSR
スポンサーリンク
概要
- 論文の詳細を見る
A beam test for the feedback damping of a coherent instability at small-laser equipped storage ring (S-LSR) was carried out. The instability caused beam loss, which limited the stored beam current to be about 600 μA during beam stacking with electron cooling. A vertical feedback damping system (VFS) using an electro-static beam position monitor (ESBPM) and a vertical kicker was applied to suppress this beam instability. The VFS realized not only suppressing the vertical coherent instability, but also revealing the characteristics of the feedback damping.
- INSTITUTE OF PURE AND APPLIED PHYSICSの論文
- 2006-12-25
著者
-
Shirai Toshiyuki
Advanced Photon Research Center And Photo Medical Research Center Japan Atomic Energy Agency
-
Noda Koji
National Institute of Radiological Sciences
-
Noda Akira
Advanced Research Center For Beam Science Institute For Chemical Research Kyoto University
-
Ikegami Masahiro
Advanced Research Center For Beam Science Institute For Chemical Research Kyoto University
-
Tongu Hiromu
Advanced Research Center For Beam Science Institute For Chemical Research Kyoto University
-
Fujimoto Shinji
Advanced Research Center For Beam Science Institute For Chemical Research Kyoto University
-
Tongu Hiromu
Advanced Research Center for Beam Science, Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011, Japan
-
Shirai Toshiyuki
Advanced Research Center for Beam Science, Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011, Japan
-
Fujimoto Shinji
Advanced Research Center for Beam Science, Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011, Japan
-
Ikegami Masahiro
Advanced Research Center for Beam Science, Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011, Japan
関連論文
- Beam-Profile Control Using an Octupole Magnet
- Novel Design for Electromagnet with Wide Excitation Range
- Proton-induced Nuclear Reactions Using Compact High-Contrast High-Intensity Laser
- A Pulse Stretcher by Slow Extraction Utilizing the Third-Order Resonance with the RF Knockout Method
- Spot Scanning Using Radioactive ^C Beams for Heavy-Ion Radiotherapy
- The Spot Scanning Irradiation with ^C Beams
- Model Test of Biperiodic L-support Disk-and-Washer Linac Structure
- Longitudinal and Transverse Coupling of the Beam Temperature Caused by the Laser Cooling of ^Mg^+
- Feedback Damping of a Coherent Instability at Small-Laser Equipped Storage Ring, S-LSR
- Bicontinuous Microemulsion Type Cleansing Containing Silicone Oil. II : Characterization of the Solution and Its Application to Cleansing Agent
- Bicontinuous Microemulsion Type Cleansing Containing Silicone Oil. I : Comparison of Solubilization Behavior of Cyclic Siloxane with Polar Oil
- Spot Scanning Using Radioactive 11C Beams for Heavy-Ion Radiotherapy
- Broadband Buncher Cavity for Beam Transport Line of HiECR Ion Source
- New Detection Device for Thomson Parabola Spectrometer for Diagnosis of the Laser-Plasma Ion Beam
- Feedback Damping of a Coherent Instability at Small-Laser Equipped Storage Ring, S-LSR