Purpose: We compared diffusion-weighted imaging (DWI) of the breast using 2 different b-values to determine the optimal b-value for greatest signal contrast between tumors and normal tissue of the breast. Materials and Methods: We performed DWI of the breast at b-values of 1000 s/mm2 and 1500 s/mm2 in 120 patients (121 lesions, 19 benign, 102 malignant) and visually scored image quality with regard to artifact and visibility of tumors. We quantitatively evaluated the signal-to-noise ratio (SNR) of the tumor and contrast-to-noise ratio (CNR) and contrast ratio (CR) between the tumor and normal breast parenchyma. Results: The CR of invasive carcinoma (IC), ductal carcinoma in situ (DCIS), and benign tumors significantly improved with b=1500 s/mm2 compared with b=1000 s/mm2. The SNR and CNR were significantly lower with b=1500 s/mm2 than b=1000 s/mm2 despite the increasing number of excitations at b=1500 s/mm2. At b=1500 s/mm2, the difference in SNR, CNR, and CR between IC and DCIS and benign tumors was statistically significant. Conclusion: DWI may depict breast tumors more clearly with b=1500 s/mm2 than b=1000 s/mm2.
著者
-
Inoue Yusuke
Department Of Biomedical Engineering Graduate School Of Medicine The University Of Tokyo
-
Woodhams Reiko
Department Of Diagnostic Radiology Kitasato University School Of Medicine
-
HATA Hirofumi
Kitasato University Hospital
-
RAMADAN Saadallah
School of Health Sciences, Faculty of Health, Hunter Building, University of Newcastle
-
OZAKI Masanori
Kitasato University Hospital
関連論文
- Correlation Between Left Ventricular Diastolic Function and Ejection Fraction in Dilated Cardiomyopathy Using Magnetic Resonance Imaging With Late Gadolinium Enhancement
- Risk and Protective Factors Related to Mortality from Pneumonia among Middle-aged and Elderly Community Residents : The JACC Study
- A nonpulsatile total artificial heart with 1/R control
- ADC Mapping of Benign and Malignant Breast Tumors
- Introducer Needles of Peripheral Intravenous Catheters : Assessment of Magnetic Field Interactions with 1.5T and 3T MR Systems
- Three-dimensional stereotactic surface projection of brain perfusion SPECT improves diagnosis of Alzheimer's disease
- Mode-Locked Fiber Lasers Using Adjustable Saturable Absorption in Vertically Aligned Carbon Nanotubes
- THE P53 GENE STATUS AND OTHER CELLULAR CHARACTERISTICS OF HUMAN CELL LINES MAINTAINED IN OUR LABORATORY
- Numerical estimation of heat distribution from the implantable battery system of an undulation pump LVAD
- Three-Dimensional CT in Isolated Dissecting Aneurysm of the Superior Mesenteric Artery: A Case Report