Investigation on Effect of Image Lag in Fluoroscopic Images Obtained with a Dynamic Flat-panel Detector (FPD) on Accuracy of Target Tracking in Radiotherapy
スポンサーリンク
概要
- 論文の詳細を見る
Real-time tumor tracking in external radiotherapy can be achieved by diagnostic (kV) X-ray imaging with a dynamic flat-panel detector (FPD). The purpose of this study was to address image lag in target tracking and its influence on the accuracy of tumor tracking. Fluoroscopic images were obtained using a direct type of dynamic FPD. Image lag properties were measured without test devices according to IEC 62220-1. Modulation transfer function (MTF) and profile curves were measured on the edges of a moving tungsten plate at movement rate of 10 and 20 mm/s, covering lung tumor movement of normal breathing. A lung tumor and metal sphere with blurred edge due to image lag was simulated using the results and then superimposed on breathing chest radiographs of a patient. The moving target with and without image lag was traced using a template-matching technique. In the results, the image lag for the first frame after X-ray cutoff was 2.0% and decreased to less than 0.1% in the fifth frame. In the measurement of profile curves on the edges of static and moving tungsten material plates, the effect of image lag was seen as blurred edges of the plate. The blurred edges of a moving target were indicated as reduction of MTF. However, the target could be traced within an error of ± 5 mm. The results indicated that there was no effect of image lag on target tracking in usual breathing speed in a radiotherapy situation.
著者
-
MORI Shinichiro
Research Center for Charged Particle Therapy, National Institute of Radiological Sciences
-
ICHIKAWA Katsuhiro
Department of Health Sciences, Graduate School of Medical Science, Kanazawa University
-
Dobashi Suguru
Research Center for Particle Therapy, National Institute of Radiological Sciences
-
KUMAGAI Motoki
Research Center for Particle Therapy, National Institute of Radiological Sciences
-
Tanaka Rie
Department of Radiological Technology, School of Health Sciences, College of Medical, Pharmaceutical
-
Kawashima Hiroki
Department of Radiology, Kanazawa University Hospital
-
Minohara Shinichi
Research Center for Charged Particle Therapy, National Institute of Radiological Sciences
-
Sanada Sigeru
Department of Radiological Technology, School of Health Sciences, College of Medical, Pharmaceutical
関連論文
- Multi-institutional retrospective analysis of the inhomogeneity correction for radiation therapy of lung cancer
- Multi-institutional Retrospective Analysis of the Inhomogeneity Correction for Radiation Therapy of Lung Cancer
- Intrafractional Respiratory Motion for Charged Particle Lung Therapy with Immobilization Assessed by Four-Dimensional Computed Tomography
- Investigation on Effect of Image Lag in Fluoroscopic Images Obtained with a Dynamic Flat-panel Detector (FPD) on Accuracy of Target Tracking in Radiotherapy
- Glycogen-rich clear cell carcinoma of the breast : a case report
- Primary small-cell carcinoma of the breast : a case report
- Pleomorphic adenoma of the breast
- Intron-Dependent Accumulation of mRNA in Coriolus hirsutus of Lignin Peroxidase Gene the Product of Which Is Involved in Conversion/Degradation of Polychlorinated Aromatic Hydrocarbons
- Biosynthetic Correlation between Streptomycin and Mucopeptide in Utilization of D-Glucosamine as a Common Precursor
- Association of polymorphisms in the beta-2 and beta-3 adrenoceptor genes with risk of colorectal cancer in Japanese
- Novel Dihydridoruthenium(II) Complexes with Chelating Diphosphine Ligands, RuH_2(CO)(diphosphine)(PPh_3)(diphosphine = dppe, dppp, dppb, and dppf)
- NEW OBJECTIVE EVALUATION METHOD FOR FUNCTIONAL BOWEL DISORDER USING VIDEO CAPSULE ENDOSCOPY
- ENDOSCOPIC APPROACH TO THE PANCREATOBILIARY TRACT USING NARROW BAND IMAGING
- MANAGEMENT OF INTRADUCTAL PAPILLARY MUCINOUS NEOPLASM OF THE PANCREAS
- Progress of endoscopic ultrasonography and intraductal ultrasonography in the diagnosis of malignant biliary diseases
- Development of Computerized Patient Setup Verification and Correction System in Radiotherapy
- Comparison of Gradation Characteristics between Three Typical Medical Imaging Display Devices Using Psychophysical Analysis
- A case of adenoid cystic carcinoma of the breast
- Interfacial Behavior of Fatty-Acylated Sericin Prepared by Lipase-Catalyzed Solid-Phase Synthesis
- Investigation on effect of image lag in fluoroscopic images obtained with a dynamic flat-panel detector (FPD) on accuracy of target tracking in radiotherapy
- Rhodium-catalyzed Highly Enantioselective [4 + 2] Annulation of 2-Alkynylbenzaldehydes with Acyl Phosphonates
- Route selection for double-balloon endoscopy, based on capsule transit time, in obscure gastrointestinal bleeding
- Intrafractional Respiratory Motion for Charged Particle Lung Therapy with Immobilization Assessed by Four-Dimensional Computed Tomography
- Multi-institutional Retrospective Analysis of the Inhomogeneity Correction for Radiation Therapy of Lung Cancer
- Preliminary Calculation of RBE-weighted Dose Distribution for Cerebral Radionecrosis in Carbon-ion Treatment Planning