Intrafractional Respiratory Motion for Charged Particle Lung Therapy with Immobilization Assessed by Four-Dimensional Computed Tomography
スポンサーリンク
概要
- 論文の詳細を見る
The aim of this study was to quantify the magnitude of intrafractional lung tumor motion under free-breathing conditions with an immobilization device using four-dimensional computed tomography (4DCT). 4DCT data sets were acquired for 17 patients with lung tumors receiving carbon ion beam therapy. A single respiratory cycle was subdivided into 10 phases, and intrafractional tumor motion was calculated by identifying the gross tumor volume (GTV) center of mass (COM) in two scenarios; respiratory-ungated and -gated treatments, which were based on a whole respiratory cycle and a 30% duty cycle around peak exhalation, respectively. For the respiratory-ungated case, the mean (± standard deviation) GTV-COM displacements from the peak exhalation position over the 17 patients were 0.6 (± 0.8) / 0.9 (± 1.2) mm, 2.0 (± 1.4) / 0.4 (± 0.7) mm, and 0.2 (± 0.5) / 7.8 (± 6.9) mm in left/right, anterior/posterior and superior/inferior directions, respectively, while these were reduced for the respiratory-gated case to 0.3 (± 0.4) / 0.4 (± 0.6) mm (left/right), 0.8 (± 0.7) / 0.3 (± 0.5) mm (anterior/posterior), and 0.1 (± 0.2) / 2.8 (± 2.9) mm (superior/inferior). Quantitative analysis of tumor motion with immobilization is valuable not only for particle beam therapy but also for photon beam therapy.
著者
-
BABA Masayuki
Research Center for Charged Particle Therapy, National Institute of Radiological Sciences
-
YAMAMOTO Naoyoshi
Research Center for Charged Particle Therapy, National Institute of Radiological Sciences
-
MORI Shinichiro
Research Center for Charged Particle Therapy, National Institute of Radiological Sciences
-
Dobashi Suguru
Research Center for Particle Therapy, National Institute of Radiological Sciences
-
Sugane Toshio
Division of Respiratory Medicine, School of Medicine, Nihon University
-
ASAKURA Hiroshi
Accelerator Engineering Corporation
-
KUMAGAI Motoki
Research Center for Particle Therapy, National Institute of Radiological Sciences
-
KANDATSU Susumu
Research Center for Particle Therapy, National Institute of Radiological Sciences
関連論文
- Carbon Ion Radiotherapy: Clinical Experiences at National Institute of Radiological Science (NIRS)
- Carbon Ion Radiotherapy : Clinical Experiences at National Institute of Radiological Science (NIRS)
- Dosimetric Factors Used for Thoracic X-Ray Radiotherapy are not Predictive of the Occurrence of Radiation Pneumonitis after Carbon-Ion Radiotherapy
- Multi-institutional retrospective analysis of the inhomogeneity correction for radiation therapy of lung cancer
- Multi-institutional Retrospective Analysis of the Inhomogeneity Correction for Radiation Therapy of Lung Cancer
- Intrafractional Respiratory Motion for Charged Particle Lung Therapy with Immobilization Assessed by Four-Dimensional Computed Tomography
- Investigation on Effect of Image Lag in Fluoroscopic Images Obtained with a Dynamic Flat-panel Detector (FPD) on Accuracy of Target Tracking in Radiotherapy
- Treatment of Patients who were Severely Exposed to Neutron and Gamma Radiation in the Recent Criticality Accident in Tokaimura
- Clinical Results of Carbon Ion Radiotherapy at NIRS
- Specification of Carbon Ion Dose at the National Institute of Radiological Sciences (NIRS)
- Chromosomal Aberrations in Lymphocytes of Lung Cancer Patients Treated with Carbon Ions
- Chromosomal aberrations in lung cancer patients' lymphocytes induced by heavy ion therapy using PCC+FISHtechniques
- Investigation on effect of image lag in fluoroscopic images obtained with a dynamic flat-panel detector (FPD) on accuracy of target tracking in radiotherapy
- Four-dimensional Computed Tomography (4D CT)-Concepts and Preliminary Development
- Intrafractional Respiratory Motion for Charged Particle Lung Therapy with Immobilization Assessed by Four-Dimensional Computed Tomography
- Multi-institutional Retrospective Analysis of the Inhomogeneity Correction for Radiation Therapy of Lung Cancer
- Physical Evaluation of Multidetector-row Computed Tomography (MDCT) Scan Methods and Conditions for Improvement of Carbon Beam Distribution