Crosstalk Analysis for Two Bent Lines Using Circuit Model(Electromagnetic Compatibility (EMC))
スポンサーリンク
概要
- 論文の詳細を見る
The crosstalk phenomenon, wich occurs between transmission lines, is caused by electromagnetic fields of currents flowing through the lines. Crosstalk between two bent lines is studied by using a set of solutions of modified telegrapher's equations. By expressing electromagnetic fields in terms of voltages and currents in the line ends, the resultant network function in the form of an ABCD matrix is obtained. Electromagnetic fields caused by currents flowing in risers at transmission line ends are taken into account in addition to those fields in line sections. The validity of the proposed approach was confirmed by comparing experimental results with computed results and those simulated by a commercial electromagnetic solver for some bent-line models.
- 社団法人電子情報通信学会の論文
- 2007-02-01
著者
-
Park Dong
Department Of Radio Science And Engineering Chungnam National University
-
PARK Sang
University of Electro-Communications
-
XIAO Fengchao
University of Electro-Communications
-
PARK Dong
Chungnum National University
-
KAMI Yoshio
University of Electro-Communications
-
Park Sang
Department Of Information And Communication Engineering University Of Electro-communications
-
Park Dong
Chungnum National Univ. Kor
-
Xiao Fengchao
Univ. Electro‐communications Chofu‐shi Jpn
-
Kami Yoshio
Univ. Electro‐communications Chofu‐shi Jpn
関連論文
- B-4-3 ANALYSIS OF CROSSTALK BETWEEN MICROSTRIP LINES IN ARBITRARY DIRECTIONS ON DIFFERENT LAYERS
- Crosstalk Analysis Method for Two Bent Lines on a PCB Using a Circuit Model(Printed Circuit Board,2nd Pan-Pacific EMC Joint Meeting-PPEMC'06-)
- Crosstalk Analysis for Two Bent Lines Using Circuit Model(Electromagnetic Compatibility (EMC))
- B-4-67 COUPLING ANALYSIS FOR PARTIALLY PARALLEL LINES OF A STRAIGHT AND BENT LINES
- B-4-33 EXPERIMENTAL ANALYSIS OF TRANSMISSION CHACTERISTICS OF BENT LINE
- Analysis of Crosstalk between Finite-Length Multiconductor Transmission Lines on a PCB by Using Circuit-Concept Approach(Printed Circuit Boards, 2004 International Symposium on Electromagnetic Compatibility)
- IS-110 3-Dimensional Culture System of Endometrial Cells for Studying the Human Implantation Mechanism
- Comparative Study on the Modulation of IgE and Cytokine Production by Phellinus linteus Grown on Germinated Brown Rice, Phellinus Linteus and Germinated Brown Rice in Murine Splenocytes
- Software Reliability Modeling Considering Fault Correction Process
- Crosstalk Analysis for Embedded-Line Structure at PCB Using Circuit-Concept Approach
- Patient with Parry-Romberg Syndrome Complicated by Coats' Syndrome
- Effect of Dietary Level of Pectin on Immunoglobulin and Cytokine Production by Mesenteric Lymph Node Lymphocytes and Interleukin-2 Receptor in Rats
- Efficacy of Dietary Aloe vera Supplementation on Hepatic Cholesterol and Oxidative Status in Aged Rats
- Angiotensin receptor blockers are superior to angiotensin-converting enzyme inhibitors in the suppression of hepatic fibrosis in a bile duct-ligated rat model
- A Prediction Method of Common-Mode Excitation on a Printed Circuit Board Having a Signal Trace near the Ground Edge(Electromagnetic Compatibility (EMC))
- A Novel Imidazo[1,5-b]isoquinolinone Derivative, U63A05, Inhibits Syk Activation in Mast Cells to Suppress IgE-Mediated Anaphylaxis in Mice
- Cost Minimization for Aperiodic Preventive Maintenance Policy (日本信頼性学会第14回信頼性シンポジウム報文集) -- (セッション8 保全計画)
- Uncaria rhynchophylla Induces Angiogenesis in Vitro and in Vivo(Pharmacognosy)
- Clinical usefulness of 18F-FDG PET-CT for patients with gallbladder cancer and cholangiocarcinoma
- Bayesian Optimal Release Time Based on Inflection S-Shaped Software Reliability Growth Model
- Bayesian Approach to Optimal Release Policy of Software System(Reliability, Maintainability and Safety Analysis)
- Analytical Solution for Two Parallel Traces on PCB in the Time Domain with Application to Hairpin Delay Lines
- Application of Rotating-EM Field to Four-Septum TEM Cell for Radiated Immunity/Susceptibility Test(Measurement and Immunity,2nd Pan-Pacific EMC Joint Meeting-PPEMC'06-)
- Time Domain Crosstalk Characteristics between Single-Ended and Differential Lines(Printed Circuit Board,2nd Pan-Pacific EMC Joint Meeting-PPEMC'06-)
- Design of a Four-Septum TEM Cell for Immunity/Susceptibility Test(Measurements, 2004 International Symposium on Electromagnetic Compatibility)
- A New Generation Method of Slowly Rotating-EM Fields for Radiated Immunity/Susceptibility Test(Measurements, 2004 International Symposium on Electromagnetic Compatibility)
- Effects of Chronic NH_4Cl Dosage and Swimming Exercise on Bone Metabolic Turnover in Rats
- Bilateral Cytomegalovirus Retinitis with Unilateral Optic Neuritis in Good Syndrome
- Conjunctival Nevus-like Lesions Originating from a Sclerotomy Site After 23-Gauge Transconjunctival Sutureless Vitrectomy
- Electrochemical Detection of Triacylglycerol Hydroperoxides by Reversed Phase High-performance Liquid Chromatography
- Simplified Interference Coupling Model for Two Orthogonal Striplines on Adjacent Layers
- Adaptive OFDM System with Optimal RCPC Code-Rate for Each Subcarrier(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Communications (ITC-CSCC 2005))
- Profit Model under Imperfect Debugging and Optimal Software Release Policy (日本信頼性学会第14回信頼性シンポジウム報文集) -- (セッション1 保全・解析〔英文〕)
- Analysis of Field Coupling to Nonuniform Transmission Lines (特集:電磁波の散乱・吸収計測技術)
- A Vector Network Analyzer Based on Seven-Port Wave-Correlator(Measuring Techniques, Recent Technologies of Microwave and Millimeter-Wave Devices Focusing on Miniaturization and Advancement in Performance with Their Applications)
- Special Issue on EMC/EMI Problems in Microwave Frequency Range
- Characteristics of Electrically Long Two-Conductor Lines with Inhomogeneous Media(Electromagnetic Compatibility(EMC))