高温における頭付きスタッドのせん断耐力に関する実験的研究

元データ 2008-08-30 社団法人日本建築学会

概要

The paper is intended to summarize findings from high-temperature tests on headed stud shear connectors conducted as part of a study on the fire resistance of composite beams. Two headed stud shear connectors on a H-shaped steel beam are embedded in two types of slab models, representing a reinforced concrete slab and a composite slab with profiled steel decks, respectively. The test parameters other than model configurations include strength of concrete, level of shear loading, and heating conditions. A total of sixteen models were tested. It is found that the most crucial design parameter is the temperature at the bottom of a headed stud shear connector. Based on the test results, a new formulation is proposed to calculate with a good accuracy the shear capacity per stud only taking account of the heat-induced degradation of steel / concrete materials.

著者

小林 裕 大成建設(株)技術センター
成原 弘之 大成建設(株)構造研究室
成原 弘之 大成建設技術センター
安田 聡 大成建設(株)技術センター
安田 聡 大成建設(株)
道越 真太郎 大成建設(株)
道越 真太郎 大成建設技術センター:東京理科大学大学院
成原 弘之 大成建設(株)
小林 裕 大成建設(株)
安田 聡 大成建設(株)技術センター研究員
道越 真太郎 大成建設技術センター

関連論文