An Ion Microprobe Analyzer
スポンサーリンク
概要
- 論文の詳細を見る
An ion microprobe mass analyzer was constructed for the analysis of solids. A beam of argon ions was used as a probe. The current and the diameter of the probe were 10^<-7> A and 0.25 mm respectively. A double focusing mass spectrometer was used to analyze the mass of the secondary ions. The mean radii of the ions in the electric field and in the magnetic field were both 10.0 cm. The deflection angles in these fields were 63.6° and 90° respectively. A Cu-Be secondary electron multiplier followed by a d.c. amplifier was used as an ion detector. Some characteristics with the variation of the peak height due to the change of the surface conditions were clarified. The relative sensitivities for Ti, V, Cr, Mn, Fe, Co, Ni in an iron alloy were determined. The detectable limits for boron in silicon and for chromium in iron were estimated to be 5 ppm and 1 ppm respectively. The distributions of nickel and chromium in the iron meteorite, Odessa, were briefly studied.
- 社団法人応用物理学会の論文
- 1969-11-05
著者
-
Okano Jun
Department Of Physics Faculty Of Science Osaka University
-
Nishimura Hiroshi
Department Of Applied Chemistry Faculty Of Engineering Osaka Institute Of Technology
-
Nishimura Hiroshi
Department of Physics, Faculty of Science, Osaka University
関連論文
- Successful electrical cardioversion of atrial fibrillation increases coronary blood flow
- Both plasma atrial natriuretic peptide and immediate improvement of left ventricular stroke volume as useful predictors of outcome of cardioversion
- Optical Spectrum of R'-Band in Spin Reorientated YbCrO_3 under High Magnetic Field
- Optical Absorption Spectrum in YbCrO_3 under High Magnetic Field
- Competitive Inclusion of Binary Flavor Mixtures in α-, β- and γ- Cyclodextrin
- Diffusion-weighted imaging of soft tissue tumors : usefulness of the apparent diffusion coefficient for differential diagnosis
- False Positive Appearance of Subarachnoid Hemorrhage on CT with Bilateral Subdural Hematomas
- Endovascular Management of an Aneurysm Arising from Posterior Inferior Cerebellary Artery Originated at the Level of C2
- Synovial Sarcoma Arising from the Chest Wall: MR Imaging Findings
- Re-entrainment of circadian rhythm of plasma melatonin on an 8-h eastward flight
- -P257- Chamber-specific Abnormalities in Sympathetic Signal Transduction Pathway in Acute Left Ventricular Failure(PROCEEDINGS OF THE 59th ANNUAL SCIENTIFIC MEETING OF THE JAPANESE CIRCULATION SOCIETY)
- Giant Angioleiomyoma in Extremity : Report of Two Cases
- Giant cell-rich osteosarcoma of the distal femur : radiographic and magnetic resonance imaging findings
- Assessment of Pancreatic CT Enhancement Using a High Concentration of Contrast Material
- PJ-519 The assessment of left anterior descending coronary artery flow before and after electrical cardioversion of atrial fibrillation using transthoracic echocardiography(Echo/Doppler 15 (I) : PJ87)(Poster Session (Japanese))
- The Increase in Coronary Blood Flow by Successful Electrical Cardioversion of Atrial Fibrillation Depends on the Left Ventricular Diastolic Function
- Sporadic amyotrophic lateral sclerosis resembling primary lateral sclerosis : Report of an autopsy case and a review of the literature
- 日本総合病院精神医学会の専門医制度
- Red thermoluminescence of enstatite from the Chainpur meteorite
- Oxygen isotope compositions of Miocene Garam Chashma granites, Trans-Himalayas (Hindukush Range), North Pakistan
- A Trial Modification of a Surface Ionization Ion Source for Direct Sample Loading for Isotope Analysis
- Isotopic Composition of Lithium in Carbonaceous Chondrites Measured by a Modified Type Surface Ionization Mass Spectrometer
- Thermoluminescence of chondrules in primitive ordinary chondrites,Semarkona and Bishunpur
- Mesomorphic Effect of Discotic-type Liquid-crystalline Compounds as Neutral Carriers on Potentiometric Ion-sensing Membranes
- Ion-sensing Behavior of Ion-selective Electrodes Based on 5, 10, 15, 20-Tetrakis (4-n-Dodecylphenyl) porphyrin
- Anomalous Systemic Arterial Supply to The Basal Segment of the Left Lung: Demonstration Using MR Angiography
- Thermoluminescence study of ordinary chondrites by TL spatial distribution readout system
- Inhibition of 1,2-Dimethyihydrazine-induced Oxidative DNA Damage by Green Tea Extract in Rat
- Compositional heterogeneity of fine-grained rims in the Semarkona (LL3) chondrite
- The chemical compositions and textures of matrices and chondrule rims of unequilibrated ordinary chondrites-II. Their constituents and the implications for the formation of matrix olivine
- Diagnostic imaging of patients with focal nodular hyperplasia of the liver
- An Attempt for the Precise Isotope Analysis: Modification of a Compact Type Mass Spectrometer.
- Anomalous g-Value of a Cr-Trimer Complex,Cr-Propionate{Cr_3O (C_2H_5COO)_6(H_2O)_3}NO_32H_2O
- Dielectric Normal Mode Relaxation of Poly(propylene oxide) and Poly(butylene oxide) in Dilute and Semidilute Solutions
- Conservative Treatment for Atrial Fibrillation Is also still Progressing
- Isotopic Abundances of Germanium Determined by Secondary Ion Mass Spectrometry
- Preliminary Report on an Electromagnetic Isotope Separator
- 1 A good rhythm-control treatment for patients with atrial fibrillation(Controversy 2 (C2) (A) : Management of Atrial Fibrillation)(Special Program)
- A Case of a Primary Hepatic Tumor Causing Segmental Changes on Imaging and Its Relation to Zahns Infarct
- An Ion Microprobe Analyzer
- Bunched Beam Instability Associated with Cavity Impedance
- Fission Product Gases from Uranium Dioxide Irradiated with Thermal Neutron
- Ion Microprobe and Electron Microprobe Studies on Magnesium Isotopic Abundances in Olivine Minerals from the Allende Carbonaceous Chondrite (SIMS特集)
- Circulating Transforming Growth Factor β-1 Level in Japanese Patients With Marfan Syndrome
- Serum Levels of Vascular Endothelial Growth Factor and Transforming Growth Factor-.BETA.1 in Patients with Atrial Fibrillation Undergoing Defibrillation Therapy.
- Purification of the multifunctional calmodulin-dependent protein kinases from lung and liver, and the comparison to the brain enzyme.
- Evolution of Virtual CT Laparoscopy for Preoperative Imaging in Laparoscopic Cholecystectomy.
- Correlation of Histology and Dynamic MR imaging (MRI) of Intracranial Meningiomas with a 0.5 Tesla MR System.
- Distal Enhancement of the Occluded Vessels on MRI in Acute Embolic Cerebral Infarction. Intravascular Enhancement Sign.:Intravascular Enhancement Sign
- Ultrasonogram of Menetrier's disease.
- Incidentally Identified Multiple Low-intensity Areas on T2-Weighted Images by MR Imaging.