Characteristics of Human Skin Impedance Including at Biological Active Points(<Special Issue>Special Section on Papers Selected from ITC-CSCC 2002)
スポンサーリンク
概要
- 論文の詳細を見る
The electrical characteristics of biologically active points (BAPs) compared with those of the surrounding human skins are investigated. We confirm that BAPs have lower resistance and higher capacitance than the surrounding skins have. We find that BAPs have higher characteristic frequency than surrounding skins and sometimes the impedance spectra of BAPs have two semicircles on the complex impedance plane. Therefore, we propose the skin impedance model that is proper to the BAPs. This model describes our experimental results sufficiently.
- 社団法人電子情報通信学会の論文
- 2003-06-01
著者
-
Park Il-yong
Advanced Research Center For Recovery Of Human Sensibility Kyungpook National University
-
Cho Jin-ho
Department Of Medical And Biological Engineering Kyungpook National University:advanced Research Cen
-
Park Hee-joon
School Of Electrical Engineering And Computer Science Kyungpook National University
-
Park Il‐yong
Kyungpook National Univ. Kor
-
CHO Jin-Ho
School of Electronic and Electrical Engineering, Kyungpook National University
-
Lee J‐w
Kyungpook National Univ. Daegu Kor
-
PARK Il-Yong
School of Electrical Engineering and Computer Science, Kyungpook National University
-
LEE Jeong-Woo
School of Electrical Engineering and Computer Science, Kyungpook National University
-
Cho Jin‐ho
Dept. Of Medical And Biological Engineering Graduate School Kyungpook National University
-
Cho J‐h
Kyungpook National Univ. Daegu Kor
-
Kim Dong-Man
School of Mechanical and Aerospace Engineering, Research Center for Aircraft Part Technology, Gyeong
-
Park Il-yong
Dept. Of Medical And Biological Engineering Graduate School Dankook University
-
Lee J‐w
School Of Electrical Engineering And Computer Science Kyungpook National University
-
Kim Dong-man
School Of Electrical Engineering And Computer Science Kyungpook National University
-
Park H‐j
School Of Electrical Engineering And Computer Science Kyungpook National University
-
Park Il-yong
School Of Electrical Engineering And Computer Science Kyungpook National University
関連論文
- Telemetry Capsule for Pressure Monitoring in the Gastrointestinal Tract(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Communications (ITC-CSCC 2005))
- New Method of Moving Control for Wireless Endoscopic Capsule Using Electrical Stimuli(Papers Selected from ITC-CSCC 2004)
- Design of Miniaturized Telemetry Module for Bi-directional Wireless Endoscopes(Special Section on Papers Selected from ITC-CSCC 2002)
- ERG Signal Modeling Based on Retinal Model(Special Section on Papers Selected from ITC-CSCC 2000)
- Vibration Modeling and Design of Piezoelectric Floating Mass Transducer for Implantable Middle Ear Hearing Devices(Engineering Acoustics)
- Multidisciplinary Aeroelastic Computation of Composite Curved Wings
- Design of a Signal Processing Module with Various Filters Characteristics for Fully Implantable Middle Ear Hearing Devices(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Communications (ITC
- A Proposal of Effective Compensation Method for IR Lamp Deterioration in NDIR Type Capnograph Systems(Special Section on Papers Selected from ITC-CSCC 2002)
- Characteristics of Human Skin Impedance Including at Biological Active Points(Special Section on Papers Selected from ITC-CSCC 2002)
- A Transcutaneous Recharging System with the Function of Bi-directional Signal Transmission for Fully-Implantable Middle Ear Hearing Devices(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Co
- High Speed LAPS System for pH Image Using Line Scanning with a Chopping Wheel
- Proposal and Evaluation of Vibration Transducer with Minimal Magnetic Field Interference for Use in IME System by in-vitro Experiment
- Vibration Analysis of Human Middle Ear with Differential Floating Mass Transducer Using Electrical Model
- Erratum: Vibration Analysis of Human Middle Ear with Differential Floating Mass Transducer Using Electrical Model [IEICE Transactions on Information and Systems E92.D (2009) , No. 10 pp.2156-2158]
- Design of a Differential Electromagnetic Transducer for Use in IME System(Speech and Hearing)
- Analytical Models and Performance Analyses of Instruction Fetch on Superscalar Processors(Special Section on Papers Selected from ITC-CSCC 2000)