A Transcutaneous Recharging System with the Function of Bi-directional Signal Transmission for Fully-Implantable Middle Ear Hearing Devices(<Special Section>Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Co
スポンサーリンク
概要
- 論文の詳細を見る
In this paper, for the fully-implantable middle ear hearing devices (F-IMEHD), a transcutaneous recharging system that has the function of the bi-directional signal transmission with the implant module in a body as well as recharging battery has been designed and implemented. The electromagnetic coupling method using two coils has been adopted for the transfer of electrical power to recharge internal battery of the implant module. To increase the efficiency of power transfer, the switching frequency of recharging system is determined by the consideration of the resonance of LC tank circuits. The bidirectional signal transmission between the recharging system and the implant module has been designed through the on-off keying modulation of switching signal in the recharging system and the impedance variation of LC tank circuit in the implant module. Through the demonstration of the implemented system, it has been verified that the proposed system has the performance of bidirectional signal transmission with the implant module of F-IMEHDs as well as the battery recharging.
- 社団法人電子情報通信学会の論文
- 2006-06-01
著者
-
Park Il-yong
Advanced Research Center For Recovery Of Human Sensibility Kyungpook National University
-
Cho Jin-ho
Department Of Medical And Biological Engineering Kyungpook National University:advanced Research Cen
-
Kim Min‐kyu
Department Of Medical And Biological Engineering Kyungpook National University
-
Kim Min-kyu
Dept. Of Medical And Biological Engineering Graduate School Kyungpook National University
-
Park Il‐yong
Kyungpook National Univ. Kor
-
Cho Jin‐ho
Dept. Of Medical And Biological Engineering Graduate School Kyungpook National University
-
Cho J‐h
Kyungpook National Univ. Daegu Kor
-
Lim Hyung-gyu
School Of Electrical Engineering And Computer Science Kyungpook National University
-
YOON Young-Ho
Advanced Research Center for Recovery of Human Sensibility, Kyungpook National University
-
SONG Byung-Seop
Dept. of Rehabilitation Science and Technology, Daegu University
-
CHO Jin-Ho
Advanced Research Center for Recovery of Human Sensibility, Kyungpook National University
-
Park Il-yong
Dept. Of Medical And Biological Engineering Graduate School Dankook University
-
Yoon Young-ho
Advanced Research Center For Recovery Of Human Sensibility Kyungpook National University
-
Song Byung-seop
Dept. Of Rehabilitation Science And Technology Daegu University
-
Yoon Young-ho
School Of Electrical Eng. And Computer Science Kyungpook National University
-
Cho Jin-ho
Advanced Research Center For Recovery Of Human Sensibility Kyungpook National University:school Of E
-
Park Il-yong
School Of Electrical Engineering And Computer Science Kyungpook National University
関連論文
- Telemetry Capsule for Pressure Monitoring in the Gastrointestinal Tract(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Communications (ITC-CSCC 2005))
- New Method of Moving Control for Wireless Endoscopic Capsule Using Electrical Stimuli(Papers Selected from ITC-CSCC 2004)
- Design of Miniaturized Telemetry Module for Bi-directional Wireless Endoscopes(Special Section on Papers Selected from ITC-CSCC 2002)
- ERG Signal Modeling Based on Retinal Model(Special Section on Papers Selected from ITC-CSCC 2000)
- Vibration Modeling and Design of Piezoelectric Floating Mass Transducer for Implantable Middle Ear Hearing Devices(Engineering Acoustics)
- Design of a Signal Processing Module with Various Filters Characteristics for Fully Implantable Middle Ear Hearing Devices(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Communications (ITC
- A Proposal of Effective Compensation Method for IR Lamp Deterioration in NDIR Type Capnograph Systems(Special Section on Papers Selected from ITC-CSCC 2002)
- Characteristics of Human Skin Impedance Including at Biological Active Points(Special Section on Papers Selected from ITC-CSCC 2002)
- A Transcutaneous Recharging System with the Function of Bi-directional Signal Transmission for Fully-Implantable Middle Ear Hearing Devices(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Co
- High Speed LAPS System for pH Image Using Line Scanning with a Chopping Wheel
- Proposal and Evaluation of Vibration Transducer with Minimal Magnetic Field Interference for Use in IME System by in-vitro Experiment
- Vibration Analysis of Human Middle Ear with Differential Floating Mass Transducer Using Electrical Model
- Erratum: Vibration Analysis of Human Middle Ear with Differential Floating Mass Transducer Using Electrical Model [IEICE Transactions on Information and Systems E92.D (2009) , No. 10 pp.2156-2158]
- Design of a Differential Electromagnetic Transducer for Use in IME System(Speech and Hearing)