ERG Signal Modeling Based on Retinal Model(Special Section on Papers Selected from ITC-CSCC 2000)
スポンサーリンク
概要
- 論文の詳細を見る
An electroretinogram(ERG) represents the global responses of the retina to a visual stimulus and shows accumulated responses of each layer of the retina relative to the signal processing mechanisms occurring within the retina. Thus, investigating the reaction types of each ERG wave provides information required for diagnosis and for identifying the signal processing mechanisms in the retina. In this study, an ERG signal is generated by simulating the volume conductor field response for each retina layer, which are then summed algebraically. The retina model used for the simulation is Shah's Computer Retina model, which is the most reliable model developed so far. When the generated ERG is compared with a typical clinical ERG it exhibits a close similarity. Based on changing the parameters of the ERG model, a diagnostic investigation is performed with a variation in the ERG waveform.
- 社団法人電子情報通信学会の論文
- 2001-06-01
著者
-
Cho Jin-ho
Department Of Medical And Biological Engineering Kyungpook National University:advanced Research Cen
-
Kim Myoung-nam
Dept. Of Biomedical Engineering School Of Medicine Kyungpook National University
-
Lee J‐w
Kyungpook National Univ. Daegu Kor
-
CHAE Seung-Pyo
the School of Electronic and Electrical Engineering, Kyungpook National University
-
LEE Jeong-Woo
the School of Electronic and Electrical Engineering, Kyungpook National University
-
JANG Woo-Young
the Department of Biomedical Engineering, Graduate School of Kyungpook National University
-
SONG Byung-Seop
the School of Electronic and Electrical Engineering, Kyungpook National University
-
KIM Myoung-Nam
the Department of Biomedical Engineering, Graduate School of Kyungpook National University
-
KIM Si-Yeol
the Department of Ophthalmology, School of Medicine, Kyungpook National University
-
CHO Jin-Ho
the School of Electronic and Electrical Engineering, Kyungpook National University
-
Chae Seung-pyo
School Of Electronic And Electrical Engineering Kyungpook National University
-
Cho Jin‐ho
Dept. Of Medical And Biological Engineering Graduate School Kyungpook National University
-
Cho J‐h
Kyungpook National Univ. Daegu Kor
-
SONG Byung-Seop
Dept. of Rehabilitation Science and Technology, Daegu University
-
Lee J‐w
School Of Electrical Engineering And Computer Science Kyungpook National University
-
Kim Si-yeol
The Department Of Ophthalmology School Of Medicine Kyungpook National University
-
Jang Woo-young
The Department Of Biomedical Engineering Graduate School Of Kyungpook National University
-
Song Byung-seop
Dept. Of Rehabilitation Science And Technology Daegu University
関連論文
- Telemetry Capsule for Pressure Monitoring in the Gastrointestinal Tract(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Communications (ITC-CSCC 2005))
- New Method of Moving Control for Wireless Endoscopic Capsule Using Electrical Stimuli(Papers Selected from ITC-CSCC 2004)
- Design of Miniaturized Telemetry Module for Bi-directional Wireless Endoscopes(Special Section on Papers Selected from ITC-CSCC 2002)
- ERG Signal Modeling Based on Retinal Model(Special Section on Papers Selected from ITC-CSCC 2000)
- Vibration Modeling and Design of Piezoelectric Floating Mass Transducer for Implantable Middle Ear Hearing Devices(Engineering Acoustics)
- Design of a Signal Processing Module with Various Filters Characteristics for Fully Implantable Middle Ear Hearing Devices(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Communications (ITC
- A Proposal of Effective Compensation Method for IR Lamp Deterioration in NDIR Type Capnograph Systems(Special Section on Papers Selected from ITC-CSCC 2002)
- Characteristics of Human Skin Impedance Including at Biological Active Points(Special Section on Papers Selected from ITC-CSCC 2002)
- A Transcutaneous Recharging System with the Function of Bi-directional Signal Transmission for Fully-Implantable Middle Ear Hearing Devices(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Co
- High Speed LAPS System for pH Image Using Line Scanning with a Chopping Wheel
- Proposal and Evaluation of Vibration Transducer with Minimal Magnetic Field Interference for Use in IME System by in-vitro Experiment
- Vibration Analysis of Human Middle Ear with Differential Floating Mass Transducer Using Electrical Model
- Design of a Differential Electromagnetic Transducer for Use in IME System(Speech and Hearing)
- Analytical Models and Performance Analyses of Instruction Fetch on Superscalar Processors(Special Section on Papers Selected from ITC-CSCC 2000)