Design of a Signal Processing Module with Various Filters Characteristics for Fully Implantable Middle Ear Hearing Devices(<Special Section>Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Communications (ITC
スポンサーリンク
概要
- 論文の詳細を見る
In this paper, the voice signal processing module has been designed using the micro processor for the use of fully implantable middle ear devices (F-IMEHD). The voice signal processing module for F-IMEHD should be designed to compensate for the hearing loss of hearing impaired person and have the flexibility for compensating various hearing threshold level. So, the voice signal processing module has been designed and implemented to present the various frequency characteristics using the low-power micro processor, MSP430F169. The different voice signal path to the inner ear entrance was considered so that two voice signal would be combined in-phase using an all pass filter with a constant time-delay to improve the vibration of the ossicles.
- 社団法人電子情報通信学会の論文
- 2006-06-01
著者
-
Park Il-yong
Advanced Research Center For Recovery Of Human Sensibility Kyungpook National University
-
Cho Jin-ho
Department Of Medical And Biological Engineering Kyungpook National University:advanced Research Cen
-
Park Hee-joon
School Of Electrical Engineering And Computer Science Kyungpook National University
-
Kim Min‐kyu
Department Of Medical And Biological Engineering Kyungpook National University
-
Kim Min-kyu
Dept. Of Medical And Biological Engineering Graduate School Kyungpook National University
-
Kim Min-kyu
Department Of Electronics Engineering Seoul National University
-
Park Il‐yong
Kyungpook National Univ. Kor
-
LEE Jyung-Hyun
School of Electronic and Electrical Engineering, Kyungpook National University
-
YOON Young-Ho
School of Electronic and Electrical Engineering, Kyungpook National University
-
WON Chul-Ho
Kyungil University
-
CHO Jin-Ho
School of Electronic and Electrical Engineering, Kyungpook National University
-
Lee Jyung-hyun
School Of Electrical Engineering And Computer Science Kyungpook National University
-
Cho Jin‐ho
Dept. Of Medical And Biological Engineering Graduate School Kyungpook National University
-
Cho J‐h
Kyungpook National Univ. Daegu Kor
-
Lim Hyung-gyu
School Of Electrical Engineering And Computer Science Kyungpook National University
-
SONG Byung-Seop
Department of Rehability Engineering, College of Rehabilitation Science, Daegu University
-
SONG Byung-Seop
Dept. of Rehabilitation Science and Technology, Daegu University
-
Park Il-yong
Dept. Of Medical And Biological Engineering Graduate School Dankook University
-
Yoon Young-ho
Advanced Research Center For Recovery Of Human Sensibility Kyungpook National University
-
Lee Jang-woo
School Of Electrical Engineering And Computer Science Kyungpook National University
-
Song Byung-seop
Dept. Of Rehabilitation Science And Technology Daegu University
-
Yoon Young-ho
School Of Electrical Eng. And Computer Science Kyungpook National University
-
Yoon Young-ho
School Of Electrical Engineering And Computer Science Kyungpook National University
-
Park H‐j
School Of Electrical Engineering And Computer Science Kyungpook National University
-
Park Il-yong
School Of Electrical Engineering And Computer Science Kyungpook National University
関連論文
- Telemetry Capsule for Pressure Monitoring in the Gastrointestinal Tract(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Communications (ITC-CSCC 2005))
- New Method of Moving Control for Wireless Endoscopic Capsule Using Electrical Stimuli(Papers Selected from ITC-CSCC 2004)
- Design of Miniaturized Telemetry Module for Bi-directional Wireless Endoscopes(Special Section on Papers Selected from ITC-CSCC 2002)
- ERG Signal Modeling Based on Retinal Model(Special Section on Papers Selected from ITC-CSCC 2000)
- Vibration Modeling and Design of Piezoelectric Floating Mass Transducer for Implantable Middle Ear Hearing Devices(Engineering Acoustics)
- Design of a Signal Processing Module with Various Filters Characteristics for Fully Implantable Middle Ear Hearing Devices(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Communications (ITC
- A Proposal of Effective Compensation Method for IR Lamp Deterioration in NDIR Type Capnograph Systems(Special Section on Papers Selected from ITC-CSCC 2002)
- Characteristics of Human Skin Impedance Including at Biological Active Points(Special Section on Papers Selected from ITC-CSCC 2002)
- A Transcutaneous Recharging System with the Function of Bi-directional Signal Transmission for Fully-Implantable Middle Ear Hearing Devices(Papers Selected from 2005 International Technical Conference on Circuits/Systems, Computers and Co
- High Speed LAPS System for pH Image Using Line Scanning with a Chopping Wheel
- Proposal and Evaluation of Vibration Transducer with Minimal Magnetic Field Interference for Use in IME System by in-vitro Experiment
- Vibration Analysis of Human Middle Ear with Differential Floating Mass Transducer Using Electrical Model
- Effect of Ambient Conditions on Spray Characteristics of Gasoline Injector
- Erratum: Vibration Analysis of Human Middle Ear with Differential Floating Mass Transducer Using Electrical Model [IEICE Transactions on Information and Systems E92.D (2009) , No. 10 pp.2156-2158]
- Super-β Bipolar Transistor Equivalent in CMOS Technology
- Design of a Differential Electromagnetic Transducer for Use in IME System(Speech and Hearing)
- IS-4 What is the Learning Curve for Single-port Access Laparoscopic-assisted Vaginal Hysterectomy?(Group1 Oncology1,International Session)
- IS-3 Identification of an ideal candidate for single-port access adnexal surgery through detailed analysis of learning curve(Group1 Oncology1,International Session)
- ISP-4-2 Angiotensin II type I receptor and miR-155 in endometrial cancers : Synergistic antiproliferative effects of anti-mir-155 and losartan on endometrial cancer cells(Group 4 Oncology 4,IS Poster,International Session)