High-Resolution Determination of Transit Time of Ultrasound in a Thin Layer in Pulse-Echo Method
スポンサーリンク
概要
- 論文の詳細を見る
In this paper we propose a new method for removing the characteristic of the piezoelectric transducer from the received signal in the pulse-echo method so that the time resolution in the determination of transit time of ultrasound in a thin layer is increased. The total characteristic of the pulse-echo system is described by cascade of distributed-constant systems for the ultrasonic transducer, matching layer, and acoustic medium. The input impedance is estimated by the inverse matrix of the cascade system and the voltage signal at the electrical port. From the inverse Fourier transform of input impedance, the transit time in a thin layer object is accurately determined with high time resolution. The principle of the method is confirmed by simulation experiments.
- 社団法人電子情報通信学会の論文
- 1995-12-25
著者
-
KANAI Hiroshi
Department of Electronic Engineering, Graduate School of Engineering, Tohoku University
-
Chubachi Noriyoshi
Department of Electrical Engineering,Faculty of Engineering,Tohoku University
-
Kanai Hiroshi
Department Of Electrical Engineering Faculty Of Engineering Tohoku University
-
Kimura Tomohisa
Department of Electrical Engineering, Faculty of Engineering, Tohoku University
-
Chubachi Noriyoshi
Department Of Electrical Engineering Faculty Of Engineering Tohoku University
-
Chubachi Noriyoshi
Deparment Of Electrical Engineering Faculty Of Engineering Tohoku University
-
Kimura Tomohisa
Department Of Electrical Engineering Faculty Of Engineering Tohoku University
関連論文
- Impact of Lifestyle-Related Diseases on Carotid Arterial Wall Elasticity as Evaluated by an Ultrasonic Phased-Tracking Method in Japanese Subjects
- Evaluation of Plaque Stabilization by Fluvastatin with Carotid Intima-Medial Elasticity Measured by a Transcutaneous Ultrasonic-Based Tissue Characterization System
- PJ-302 High-Resolution Measurement of Carotid Artery Wall Elasticity for Clinical Tailor-Made Risk Management of Arteriosclerosis(Atherosclerosis, clinical-09, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- Usefulness of measurement of carotid arterial wall elasticity distribution in detection of early-stage atherosclerotic lesions caused by cigarette smoking
- PE-166 Influence of Cardiovascular Risk Factors on Carotid Arterial Elasticity Measured by the Transcutaneous Ultrasonography Using Phased-tracking Method(Atherosclerosis, clinical-7 (H) PE28,Poster Session (English),The 70th Anniversary Annual Scientific
- Imaging of Takayasu Arteritis with the Phased Tracking Method(Echo/Doppler 2 (I), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- PE-421 Early Detection of Vascular Remodeling by Angiotensin II Receptor Blockers with Carotid Arterial Elastic Modulus in Essentail Hypertension(PE071,Echo/Doppler (Peripheral/Vascular) (I),Poster Session (English),The 73rd Annual Scientific Meeting of t
- PE-421 Early Detection of Vascular Remodeling by Angiotensin II Receptor Blockers with Carotid Arterial Elastic Modulus in Essentail Hypertension(PE071,Echo/Doppler (Peripheral/Vascular) (I),Poster Session (English),The 73rd Annual Scientific Meeting of t
- PE-166 Influence of Cardiovascular Risk Factors on Carotid Arterial Elasticity Measured by the Transcutaneous Ultrasonography Using Phased-tracking Method(Atherosclerosis, clinical-7 (H) PE28,Poster Session (English),The 70th Anniversary Annual Scientific
- IS083 Mechanism of coronary flow modulation at phase-controlled vibration in open chest canine preparation
- -0640-A NEW TRIAL FOR NON-INVASIVE ESTIMATION OF LV DIASTOLIC PRESSURE
- Improved imaging of the carotid artery in the short-axis plane by a mechanical scanning ultrasonic probe
- PE-326 Efficacy of Valsartan on Carotid Arterial Wall Elastic Modulus and Urinary Albumin Excretion in Diabetic Patients(Echo/Doppler(07)(I),Poster Session(English),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- Evaluating the regional elastic modulus of a cylindrical shell with nonuniform wall thickness
- OE-249 Effects of changes in Coronary perfusion on Subendocardial contractility Assessed with the novel high-resolution Doppler method(Echo/Doppler 11 (I) : OE31)(Oral Presentation (English))
- A technique of measuring relative sound velocity changes using a frequency variable type ultrasonic correlation system
- Measurement of Ultrasonic Velocity in Liquid Using a Modified Ultrasonic Correlation System Under Low S/N Condition : Acoustical Measurements and Instrumentation
- Velocity Measurement in Liquids by using Reflection Type Ultrasonic Correlator via Wave number Analysis in MHz Range : Physical Acoustics
- Measurement of Rapid Variation in Ultrasound Backscattering During Change in Thickness of Tissue Phantom
- Blood flow structure and dynamics, and ejection mechanism in the left ventricle : Analysis using echo-dynamography
- Measurement and Analysis of Vibrations on Surface of Phantom Induced by Piezoelectric Extracorporeal Shock Wave Lithotripter
- Power Difference in Spectrum of Sound Radiation before and after Break of Phantom by Piezoelectric Extracorporeal Shock Wave Lithotriptor
- PJ-259 Carotid Artery Elasticity Using the Phased-Tracking Method is Useful as a Risk Factor for Ischemic Heart Disease(PJ044,Atherosclerosis (Clinical/Diagnosis) 2 (IHD),Poster Session (Japanese),The 73rd Annual Scientific Meeting of The Japanese Circula
- Evaluation of Piezoelectric Ceramic Substrates for Ultrasonic Bulk Wave Filters and Resonators Using Pulse Interference Method
- Sensitivity of the myocardial systolic visco-elastic properties under brief period coronary flow reduction, evaluated by the wave transmission
- PARCORR-Based Time-Dependent AR Spectrum Estimation of Heart Wall Vibrations (Special Section on Advanced Signal Processing Techniques for Analysis of Acoustical and Vibrational Signals)
- High-Resolution Determination of Transit Time of Ultrasound in a Thin Layer in Pulse-Echo Method
- A new method to measure bone properties by means of leaky surface acoustic waves
- Optimization of Condition of Ultrasonic Beam for Measurement of Small Change in Thickness of Arterial Wall
- Measurement of nonlinear property of artery wall using remote cyclic actuation
- Transmural Histological Heterogeneity and LVEDP Elevation in HCM
- Transmission Line Model Equivalent Circuit for Piezoelectric Transducers Including the Effect of Electrical Terminal Impedance
- Motivating Basic Research in the University
- Noninvasive Measurement of Stiffness and Density of Bone for Its Diagnosis Using Ultrasound
- A Basic Study on Nondestructive Evaluation of Potatoes Using Ultrasound : Acoustical Measurements and Instrumentation
- Chemical Isotropic Etching of Single-Crystal Silicon for Acoustic Lens of Scanning Acoustic Microscope
- Mechanically Scanned Acoustic Microscope
- Off-Centric Concave Transducer for Acoustic Microscopy : Ultrasonic Microscopy and Nondestructive Testing
- Heart murmur transmitted to the myocardium determines ventricular function and transmural myocardial functional heterogeneity
- Relationship between passive thickening of transmural myocardial layer at late diastole and elevated LVEDP in HCM
- Spiral systolic blood flow in the ascending aorta and aortic arch analyzed by echo-dynamography
- Simultaneous Measurement of Vibrations on Arterial Wall Upstream and Downstream of Arteriostenosis Lesion and Their Analysis
- Non-Contact Simultaneous Measurement of Thickness and Acoustic Properties of a Biological Tissue Using Focused Wave in a Scanning Acoustic Microscope : Medical Ultrasonics and Ultrasonic Measurements
- Systolic Heterogeneity of Transmural Myocardial Function in Normal Subjects : Physiological Functional Heterogeneity
- A Remote Measurement Method of Acoustic Velocity in Liquids by a Pair of Leaky Rayleigh Waveguides : Acoustical Measurements and Instrumentation
- Scanning Acoustic Microscope Employing Concave Ultrasonic Transducers : Physical Acoustics I
- A New Ultrasonic Amplifier Device of CdS Crystal with Integrated Diffusion-Layer Transducers
- Measurement of shear wave propagation and investigation of estimation of shear viscoelasticity for tissue characterization of the arterial wall
- Measurements of Acoustic Properties of Teeth by Impulsive-Wave Acoustic Microscope System : Medical Ultrasonics
- Systolic Heterogeneity of Transmural Myocardial Function in Normal Subhects: Physiological Function Heterogeneity
- Spatial Distribution Measurement of Heart Wall Vibrations Generated by Remote Perturbation of Inner Pressure
- Optimization of Focal Position of Ultrasonic Beam in Measurement of Small Change in Arterial Wall Thickness
- Measurement of Rapid Variation in Ultrasound Backscattering During Change in Thickness of Tissue Phantom
- Physiological basis and clinical significance of left ventricular suction studied using echo-dynamography