Dimensional Accuracy and Surface Property of Titanium Casting Using Gypsum-bonded Alumina Investment
スポンサーリンク
概要
- 論文の詳細を見る
The aim of the present study was to evaluate the dimensional accuracy and surface property of titanium casting obtained using a gypsum-bonded alumina investment. The experimental gypsum-bonded alumina investment with 20 mass% gypsum content mixed with 2 mass% potassium sulfate was used for five cp titanium castings and three Cu-Zn alloy castings. The accuracy, surface roughness (Ra), and reaction layer thickness of these castings were investigated. The accuracy of the castings obtained from the experimental investment ranged from -0.04 to 0.23%, while surface roughness (Ra) ranged from 7.6 to 10.3 μm. A reaction layer of about 150 μm thickness under the titanium casting surface was observed. These results suggested that the titanium casting obtained using the experimental investment was acceptable. Although the reaction layer was thin, surface roughness should be improved.
- 日本歯科理工学会の論文
著者
-
Takahashi Hidekazu
Advanced Biomaterials Department Of Restorative Sciences Division Of Oral Health Sciences Graduate S
-
Nishimura Fumio
Advanced Biomaterials Department Of Restorative Sciences Division Of Oral Health Sciences Graduate S
-
Yan M
中華人民共和国
-
Yan Min
Institute Of Oral Materials Science Chung Shan Medical University
-
Takahashi Hidekazu
Advanced Biomaterials Department Of Restorative Science Division Of Oral Health Science Graduate Sch
-
Takahashi Hidekazu
Advanced Biomaterials Department Of Restorative Sciences Division Of Oral Health Sciences Graduate S
関連論文
- Effects of Silane Coupling Agent Amount on Mechanical Properties and Hydrolytic Durability of Composite Resin After Hot Water Storage
- Effect of filler type and polishing on the discoloration of composite resin artificial teeth
- P-63 Mechanical properties of enamel resin of veneering composite resin systems
- Effects of plasma treatment on the shear bond strength between fiber-reinforced composite posts and resin composite for core build-up
- Effect of NaClO Treatment on Bonding to Root Canal Dentin Using a New Evaluation Method
- Properties of a gypsum-bonded magnesia investment using a K_2SO_4 solution for titanium casting
- A Gypsum-Bonded Magnesia Investment is Available for Titanium Casting
- Effect of Ultraviolet Light Irradiation on Bonding of Experimental Composite Resin Artificial Teeth
- P-32 Evaluation of impact absorption using free falling object
- P-7 Effect of UV irradiation on bonding of experimental composite resin
- P-90 Shear bond strength of experimental denture teeth composite resin : Effect of surface treatment
- Titanium casting using Magnesia-based Gypsum-bonded investment : Part 1. Basic properties of investment
- Fundamental Studies on Ammonia-free Phosphate-bonded Binder for Dental Investments
- The Possibility of Fabricating Co-Cr Casting Plates by Using a Heat-Shock Method with Conventional Phosphate-Bonded Investments
- Two-stage Heat-Shock Procedure Can Fabricate Sound Co-Cr Casting Denture Plates by Using Conventional Phosphate-Bonded Investments
- Effects of Heat arid pH in Silanation Process on Flexural Properties and Hydrolytic Durabilities of Composite Resin after Hot Water Storage
- Bonding Properties of Heat-polymerized Denture Base Resin to Ti-6Al-7Nb Alloy
- Analysis of Er:YAG Lased Dentin Using Attenuated Total Reflectance Fourier Transform Infrared and X-ray Diffraction Techniques
- Human osteoblast-like cell spreading and proliferation on Ti-6Al-7Nb surfaces of varying roughness
- Effect of reactive adhesives on the tensile bond strength of polyvinyl siloxane impression materials to methyl methacrylate tray material
- Reinforcement effects of fiberglass on telescopic dentures using a three-dimensional finite element analysis and fracture test
- Basic Evaluation of Cast Joining for Electroformed Coping using Multi-purpose Alloys
- Effective Factors Including Periodontal Ligament on Vertical Root Fractures
- Effects of Cyclic Loading on Viscoelastic Properties of Soft Lining Materials
- Improving a Self-curing Dental Resin by Eliminating Oxygen, Hydroquinone and Water from its Curing Process
- Effects of Water Pressure during Polymerization on Mechanical Properties of Autopolymerized Resins
- Bonding durability of custom-made mouthpiece for scuba diving after water storage under pressure
- Effect of Degradation of Denture Base Resin on Bond Strength to Relining Resins
- Tensile strength of dentin after bleaching treatment
- Effect of Polymorphism of SiO_2 Addition on Mechanical Properties of Feldspathic Porcelains
- Basic evaluation on physical properties of experimental fluorinated soft lining materials
- Influence of methyl mercaptan at early setting stages on the properties of self curing addition silicone resilient denture lining materials
- Influence of a denture strengthener on the deformation of a maxillary complete denture
- Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location
- Radiopacity of Experimental Composite Resins Containing Radiopaque Materials
- Effect of mold temperatures on interface between primary and secondary castings of cast-on method for precision metal frameworks
- Reinforcement of Denture Base Resin with Short-rod Glass Fiber
- Effect of Test Method on Flexural Strength of Recent Dental Ceramics
- Dimensional Accuracy and Surface Property of Titanium Casting Using Gypsum-bonded Alumina Investment
- Titanium Casting Using Commercial Phosphate-bonded Investments with Quick Heating Method