P-MB-03 Measurement and Valuation of Touch Sensation
スポンサーリンク
概要
- 論文の詳細を見る
This paper is a study on the measurement and valuation of touch sensation of various kinds of clothes. The tactile sensor with PVDF film as the sensory receptor and the device for moving the sensor are assembled. The human haptic feelings of wear of several clothes are examined by means of questionnaires and compared with the output of piezopolymer sensor. The measured objects are underwear and polo shirts with total 13 sheets. Comparison with the results shows that the PVDF sensor well describes the tactile perception of human.
- 一般社団法人日本機械学会の論文
著者
-
Tanaka Mami
Department Of Bioengineering And Robotics Graduate School Of Engineering Tohoku University
-
Chonan Seiji
Department Of Bioengineering And Robotics Graduate School Of Engineering Tohoku University
-
Chonan Seiji
Department Of Aeronautics And Space Engineering Tohoku University
-
Tanaka Mami
Department Of Bioanalytical Science Osaka Prefecture College Of Health Sciences
-
Tanaka Yoshihiro
Department Of Bioengineering And Robotics Graduate School Of Engineering Tohoku University
関連論文
- Challenge for a better combination with basic evidence
- Keratin 19 in Benign Ameloblastomas and Malignant Ameloblastoma : Immunohistochemistry, Reverse Transcription : Polymerase Chain Reaction and Northern Blot Analysis
- Interstitial Brachytherapy for Carcinoma of the Tongue Using microSelectron-HDR
- Interstitial pregnancy in a woman with congenital afibrinogenemia
- K3-IS-1 Endometrial cancer side population cells show characteristics of cancer stem-like cell
- Intraorbital Subperiosteal Hematoma due to Paranasal Mucocele : Case Report
- Charge Separation in Zinc Diporphyrin-Zinc Porphyrin-Pyromellitimide-Quinone Tetrads
- BIO-08 DEVELOPMENT OF A HAPTIC SENSOR FOR MONITORING HUMAN SKIN CONDITIONS : MEASUREMENT OF SOFTNESS, SMOOTHNESS, AND TACKINESS(Bio-medical Equipments III,Technical Program of Oral Presentations)
- Detection of Biotin-Binding Immunoglobulin G in Human Sera Using Avidin-Coated Multiwell Microplates
- BIO-10 DEVELOPMENT OF A CURVATURE SENSOR USING A SOLID POLYMER ELECTROLYTE(Bio-medical Equipments III,Technical Program of Oral Presentations)
- Giant Aneurysm of the Azygos Anterior Cerebral Artery
- ACTIVE TACTILE SENSING USING A TWO-FINGER SYSTEM
- CALCIUM UPTAKE AND MITOCHONDRIAL FUNCTION OBSERVED IN SITU IN CARDIOMYOCYTES OF EXPERIMENTAL DIABETIC RATS
- Bilateral Absence of the Internal Carotid Artery : Case Report
- Development of a tactile sensor system for reading Braille (Signal processing for robust recognition)
- P-MB-04 Development of a Tactile Sensor for Reading Braille
- Development of a haptic sensor for measuring skin morphological features
- Soundproof Characteristics and the Design of Three-Layered Cylindrical Shells
- Acoustic Characteristics and the Design of Two-Layered Cylindrical Shells
- Shock-proof design of head disk assembly subjected to impulsive excitation
- Measurement and valuation of touch sensation (Warm feeling compared with PVDF sensor output)
- P-MB-03 Measurement and Valuation of Touch Sensation
- Closed-Loop Displacement Control of a One-Link Flexible Arm with a Tip Mass
- Development of a wearable mental stress evaluation system using PVDF film sensor
- Intracerebral Hemorrhage in Patients With Chronic Liver Disease
- Pure Germinoma of the Pineal Gland With Synchronous Spinal Dissemination : Case Report
- Formation of TiO2(B) Prepared from Lepidocrocite Type Precursor Containing Potassium
- Clozapine responders may have fewer extrapyramidal symptoms than non-responders: a preliminary report
- INHIBITORY ACTIVITY OF ABOB ON THE GROWTH OF INFLUENZA VIRUS A (Hong Kong)