小試料粘度計の改良とその応用
スポンサーリンク
概要
- 論文の詳細を見る
We have previously reported a new capillary viscometer in which two syringe needles are connected to top and bottom end of a graduated glass tube and negative pressure is introduced by compressing a rubber ball. The viscosity of liquid was read by the maximum height of liquid sucked into the glass tube. In this device the gravitational force due to the weight of liquid worked against the negative pressure in the tube. this required a correction in calibration curves for the scale of the scale of tube and viscosity, and necessitated watching the instant when the liquid went up to the highest level. In the present modification, the needle at the lower end is brought to the upper side of the tube, and the bottom of the tube is closed. The liquid is drawn in the tube by pressing a bellows made of phosphor bronze plates, and kept at the bottom of the tube. The reading of the height of liquid is easily made, and the correction for gravity is not necessary in the calibration curve. The relation between the viscosity of liquid n and the volume V_l of liquid sucked derived from the Poiseuille law in the form : [numerical formula] where η_a is the viscosity of air, V the volume evacuated by a bellows, R_l, R_a and L_l, L_a the radii and lengths of two needles, where suffixes l and a mean the liquid and the air respectively. This relation was verified to hold well by measurements of the viscosities of standard oils. However, for the viscosity range lower than several centipoises, it was found that the correction for kinetic energy of flow should be added to the equation mentioned above. The measurable range of viscosity can e adjusted by the adequate combination of dimensions of two needles and cover from 0.5 to 150 centipoises. The shear rate is altered in the range 10 sec^<-1> 〜 10^3 sec^<-1> by replacing a bellows by a motor driven pressure reduction device. The volume of liquid needed is less than 3ml and the time required is less than several seconds. The examples illustrate the intrinsic viscosity of aqueous solution of polyvinylalcohol, the temperature variation of viscosity of oils and the temperature and concentration dependence of viscosity of milk.
- 社団法人日本材料学会の論文
- 1965-04-15
著者
関連論文
- Cheeseの粘弾性と水分効果
- 粘稠物質のロール面上の縞模様III(高分子)
- 可塑性物質の非線形粘弾性現象 : 分散系のレオロジー,その他
- 6p-A-5 可塑性物質の非線型粘弾性
- バターのチクソトロピーと結晶化度 : レオロジー一般
- 粘稠物質のロール面での縞模様 (II) : 高分子
- 粘稠物質のロール面での異常流動 : 高分子
- 練圧によるバターの粘度の変化 : レオロジー一般
- 酢酸セルロースの複素圧電率の温度による分散吸収
- 5p-M-8 ポリ塩化ビニル・スチレン・グラフトポリマーの動的粘弾性
- 27p-A-10 Poly(D-lactic acid)の光学活性
- 118. 胎児・新生児血液の粘弾性に関する研究 (第1報)
- フィブリノーゲン-トロンビン凝固反応の動的粘弾性による研究
- 凝固過程での血液の非ニュートン粘性と動的粘弾性
- 3p-K-8 凝固過程での血液の動的粘弾性
- ソフトマテリアルの研究
- バイオレオロジー研究の進歩
- 29p-WA-7 Poly-γ-Methyl-L-Glutamateの光学活性
- 27a-ZC-1 ポリ乳酸の光学的及びX線的研究
- 4P-TC-10 Poly(L-lactic acid)の光学活性II
- 31a-M-6 poly(L-lactic acid)の電気光学及び電気旋光効果
- 6p-P-6 Poly (L-lactic acid)の光学活性
- セルロースおよび木材の低温での圧電緩和(木質材料小特集)
- 高分子化学--合成ポリペプチドの電気力学的物性 (1975年の化学-12完-)
- フィブリン延伸膜の圧電性,誘電性および粘弾性
- 7a-Y-1 高分子固体り電気的性質
- 電石
- 9p-K-8 高分子セラミック混合体の圧電分散
- 光学活性ポリプロピレンオキサイドの圧電分散 : 高分子
- 油脂の結晶化挙動と粘弾性
- 小試料粘度計の改良とその応用
- コラーゲン稀薄溶液に対する放射線照射効果 : 高分子
- トリステアリン-トリオレイン二成分系のレオロジー的性質 : 分散形のレオロジー, その他
- 小試料の新しい毛細管粘度計と血液の粘度研究への適用 : 生物のレオロジー
- ミルクおよびミルクゲルのレオロジー : 分散系のレオロジー : レオロジー特集号
- 平行板プラストメーターによる可塑性脂肪の粘弾性 : 分散型のレオロジー
- 平行板プラストメーターによる粘弾性の研究 : 高分子
- 電気刺激による骨形成
- (2)生体レオロジーにおける測定方法
- 5a-P-3 カルナウバ蝋及びその構成物質誘導体のエレクトレット
- 5p-KP-8 薄板状カルナウバ蝋エレクトレットの特性
- 6p-Y-5 カルナウバ蝋エレクトレットの脱分極電流
- 2p-TE-3 カルナウバ蝋エレクトレットの脱分極電流
- 9p-K-7 カルナウバワックスエレクトレットの寿命
- エレクトレットの脱分極と分子運動 : 高分子
- ロール延伸したポリ弗化ビニリデンのエレクトレット : 高分子
- Effects of Drying on Deoxyribonucleic Acids
- 低ずり速度での血液の構造粘性
- 岡小天先生の研究の追憶
- 生物の成長と電気現象
- 提言
- 高分子強誘電体
- 測定装置を作る楽しみ (高分子科学における新しい測定法)
- 先輩に学ぶ (これから高分子を学ぶ人のために)
- 生体高分子の圧電気
- ABSTRACTS
- A Review on Rheometry