Multiphoton Ionization of K_2 in the Wavelength Range 600-670 nm
スポンサーリンク
概要
- 論文の詳細を見る
The relative produc:lion rates of K" and K.' ions tFxrough the multiphoton ionizalion of K. are measured in the wavelength range 600-670 nm. These rates for K; ionshave a threshold at about 600 nm and a broad peak at about 620 nm. These for K "ions have the threshold at about 612 nm and the position of the peak is roughly equalto that of K." ion. The effective order of nonlinearity k, which is the minimumnumber of photons necessary to ionize the K. molecule, is measured as a function ofthe wavelength. k for K " ions is about 3 in 613-650 nrn, except for that at 634 nm, atwhich k is about 2.3. On the other hand, kfor K; is about 2 in the wavelength rangeshorter than 611 nm ;tnd two values of k in 632-637 11111 are about 1.6. Beyond 637nrn, k increases with an increase of wavelength and reaches about 2.6 at 650 nm.From these results, the production processes of K" and K.' ions are discussed.
- 社団法人日本物理学会の論文
- 1992-06-15
著者
-
KATO Hideo
Department of Health Sciences, Faculty of Human Culture and Science, Prefectural University of Hiros
-
Suemitsu Hidetoshi
Department Of Engineerng Physics Fadulty Of Engineering Kyoto University
-
Suemitsu Hidetoshi
Department Of Engineering Science Faculty Of Engineering Kyoto University
-
Suemitsu Hidetoshi
Department Of Engineering Physics Faculty Of Engineering Kyoto University
-
Imanishi Hiroaki
Department Of Engineering Science Faculty Of Engineering Kyoto University:kansai Electric Power Co.
-
Kato Hideo
Department Of Engineering Science Faculty Of Engineering Kyoto University
-
KATO HIDEO
Department of Biology, Yokohama City University
関連論文
- Compartment syndrome after Femoral Artery Cannulation for Cardiopulmonary Bypass : Report of a Case
- Perinatal and Postnatal Exposure to Bisphenol A Increases Adipose Tissue Mass and Serum Cholesterol Level in Mice
- Processes of Multiphoton Ionization of Cs_2 in the Wavelength Range 620-670 nm
- Non-Thermal Radiation at Runaway Electron Instability
- Two-Photon Ionization of Cs_2 in the Wavelength Range 5300-6200 A^^゜
- Early Gastric Cancer Manifested as Brain Metastasis: Report of a Case
- Bile Peritonitis Due to a Spontaneous Perforation of the Common Bile Duct : Report of a Case
- Multiphoton Ionization of RbCs in the Wavelength Range 540-620 nm
- Successful treatment of gallbladder carcinoma producing alpha-fetoprotein with segmental adenomyomatosis
- ANTITUMOR ACTIVITY OF DL-1-β-CHLOROETHYL-2-CHLOROMETHYLPIPERIDINE HYDROBROMIDE (CAP-1) ON SOME RODENT TUMORS∗
- Extreme Ultraviolet Emission and Ionization O-ions in a Linear Z-Pinch Helium Plasma
- A New Grazing Incidence Spectrometer and Extreme Ultraviolet Spectra of Light Impurity Ions in Linear Pinch Plasmas
- Multiphoton Ionization of K_2 in the Wavelength Range 600-670 nm
- Occurrence of Lordosis-like Posture in Male and Female Mice Given Manual Stimulation During the Early Period of Anesthesia
- Contraction of Plasma in a Linear Z-Pinch Tube
- Vacuum Ultraviolet Emissions from Linear Pinch Rare Gas Plasmas and Their Applications as a Light Source
- Characteristics of Plasma Compression in Z-Pinch Discharge
- Outer 2s-Shell Electron Excitation Emission from C-, N-and O-Impurity Ions in Linear Z-Pinch He Plasma
- Effects of Cyclic and Continuous Total Enteral Nutrition on 24-h Rhythms of Body Temperature and Urinary Excretions.