Statistical Evaluation of Titanium Metal Base Dentures Used in Vivo
スポンサーリンク
概要
- 論文の詳細を見る
A review of the statistics and outcomes related to the use of titanium dentures used at the Tsurumi University Dental Hospital between 1992 and 1998 was previously reported. This report contains details of the evaluation of the use of titanium dentures between 1999 and 2007.The patients were partially or completely edentulous individuals who received prosthodontic treatment, including cast partial or complete dentures, at the Tsurumi University Department of Removable Prosthodontics between 1999 and 2007. According to the laboratory instructions at the Tsurumi University Dental Laboratory Center, the denture frameworks were classified as partial (PD) or complete (CD) and fabricated from commercially pure titanium (CPTi), a titanium alloy (Ti Alloy), a cobalt-chromium alloy (Co-Cr), and a Type IV gold alloy (Au-Pt).From April 1999 to March 2007, we prepared a total of 1,470 cast metal plate dentures, 295 (20.1%) of which were made with titanium. CP Ti (Grade 3) dentures were used in 263 patients (17.9%), and Ti Alloy (Ti-6Al-7Nb) dentures were used in 32 (2.2%). The majority of the cast plates were made with Co-Cr (995, 67.7%). CP Ti is well known to be softer and more prone to wear than Ti-6Al-7Nb but is frequently used for the preparation of partial dentures at our University because of its high biocompatibility.CP titanium is favorable because it rarely results in metal allergy, and is lightweight.
- 2008-07-01
著者
-
OHKUBO Chikahiro
Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine
-
HOSOI Toshio
Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine
-
Yamazaki Nobuo
Department Of Physics Tokyo University Of Education
-
Yamazaki Nobuo
Department Of Removable Prosthodontics Tsurumi University School Of Dental Medicine
-
Hosoi Toshio
Department Of Removable Prosthodontics Tsurumi University School Of Dental Medicine
-
MIZUNO Yukihiro
Training Institute of Dental Technician, Tsurumi University School of Dental Medicine
-
DAN Tomoko
Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine
-
Ohkubo Chikahiro
Department Of Removable Prosthodontics Tsurumi University School Of Dental Medicine
-
Ohkubo Chikahiro
Department Of Removable Prosthodontics School Of Dental Medicine Tsurumi University
-
Mizuno Yukihiro
Training Institute Of Dental Technician Tsurumi University School Of Dental Medicine
-
Dan Tomoko
Department Of Removable Prosthodontics Tsurumi University School Of Dental Medicine
関連論文
- Retentive Force of the Konus Telescope on One-piece Implant
- Retentive Forces of 3 Types of Attachments for Root-retained Overdentures
- Application of Thermography in Dentistry : Visualization of Temperature Distribution on Oral Tissues
- Bending Strengths of Metal Framework Structures for Implant-stabilized Overdentures
- Functional Efficacy of Full Balanced Occlusion and Lingualized Occlusion Evaluated from Morphological Differences in the Edentulous Alveolar Ridge
- Fluidity and Hardening Time of Autopolymerized Denture Repair Acrylic Resin : A Comparison of Brush-on Technique and Mixing Technique
- Impression Accuracy of Sectional Stock Tray System
- Clinical Evaluation of In-Ceram Crowns Fabricated Using GN-I System : Preliminary Results after 24-39 Months of Use
- Clinical Evaluation of Marginal and Internal Gaps of Zirconia-based 3-unit CAD/CAM Fixed Partial Dentures
- A Procera^【○!R】 Custom Abutment Fabricated by Scanning the Provisional Abutment
- Joint Strengths of Metal Framework Structures for Removable Partial Dentures
- Prosthesis Made of an Onlay-Type Rest with High Retentive Force (Cap Clasp)
- Statistical Evaluation of Titanium Metal Base Dentures Used in Vivo
- Comparison of the Attractive Forces of Dental Magnetic Attachments Fabricated by Cast- and Direct-Bonding Techniques
- Surface Analysis of Keepers on Dental Magnetic Attachments : Comparison of Cast-Bonding Technique and Direct-Bonding Technique
- Influence of Neuroticism on Denture Wear
- Implant Placement for Mandibular Overdentures using the Neutral Zone Concept
- Influence of denture treatment on brain function activity
- Survey on use of titanium dentures in Tsurumi University Dental Hospital for 11 years
- Clinical Evaluation of Porcelain Fused to Electroformed Gold Coping Crowns : Preliminary Results after 30-43 Months
- Prospective Clinical Study of Procera AllCeram Crowns : 2-3 year Preliminary Results
- Scaling and Duality Scheme in Deep Inelastic Processes
- Hadron Total Cross Sections in the Quark Parton Model
- Condition of depressive symptoms among Japanese dental students
- A New Retainer Using Magnetic Attachment
- Effects of argon gas flow rate on laser-welding
- Influence of thickness and undercut of thermoplastic resin clasps on retentive force
- Inhibitory effect of coated mannan against the adhesion of Candida biofilms to denture base resin
- Fabrication of fixed implant prostheses using function bite impression technique (FBI technique)
- Effect of implant support on mandibular distal extension removable partial dentures: Relationship between denture supporting area and stress distribution
- Evaluation of psychological effect of prosthetic treatment using Emotion Spectrum Analysis Method (ESAM)
- Long-term clinical evaluation of implant over denture