Joint Strengths of Metal Framework Structures for Removable Partial Dentures
スポンサーリンク
概要
- 論文の詳細を見る
Purpose : This study investigated the joint strengths of two frameworks for removable partial dentures (RPD) embedded in a denture base resin.Materials and Methods : Six types of framework structures were cast conventionally from a Co-Cr alloy. To connect two castings, six types of joints were designed : Type A (butt joint), Type B (soldered butt joint), Type C (soldered lap joint), Type D (10 mm overlapped T-shape), Type E (20 mm overlapped T-shape), and Type F (Type D with two pins). Two castings were embedded in denture base resin and finished to a size of 10.0×10.0×65.0 mm. As a control, the same size resin block without a framework was prepared. Joint strengths were determined using a three-point bending test. To evaluate the strength change after rejoining, the broken specimens were reconnected using the same resin and tested as in the first test.Results : Both the breaking load and maximum stiffness of Types D, E, and F were significantly (p<0.01) greater than those of Types A, B, and C. Using the same resin for repair, the joint strengths of every type were not significantly (p>0.05) different between the before- and after-repair state.Conclusion : Because of the design of the three-dimensional RPD frameworks, greater joint strengths were obtained than for the conventional soldered framework design.
- 日本補綴歯科学会の論文
- 2002-10-01
著者
-
OHKUBO Chikahiro
Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine
-
HOSOI Toshio
Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine
-
Kurtz Kenneth
Advanced Program In Prosthodontics For International Dentists New York University College Of Dentist
-
Hosoi Toshio
Department Of Removable Prosthodontics Tsurumi University School Of Dental Medicine
-
KURTZ Kenneth
International Program in Prosthodontics, New York University
-
Ohkubo Chikahiro
Department Of Removable Prosthodontics School Of Dental Medicine Tsurumi University
関連論文
- Retentive Force of the Konus Telescope on One-piece Implant
- Retentive Forces of 3 Types of Attachments for Root-retained Overdentures
- Application of Thermography in Dentistry : Visualization of Temperature Distribution on Oral Tissues
- Bending Strengths of Metal Framework Structures for Implant-stabilized Overdentures
- Functional Efficacy of Full Balanced Occlusion and Lingualized Occlusion Evaluated from Morphological Differences in the Edentulous Alveolar Ridge
- Fluidity and Hardening Time of Autopolymerized Denture Repair Acrylic Resin : A Comparison of Brush-on Technique and Mixing Technique
- Impression Accuracy of Sectional Stock Tray System
- Clinical Evaluation of In-Ceram Crowns Fabricated Using GN-I System : Preliminary Results after 24-39 Months of Use
- Clinical Evaluation of Marginal and Internal Gaps of Zirconia-based 3-unit CAD/CAM Fixed Partial Dentures
- A Procera^【○!R】 Custom Abutment Fabricated by Scanning the Provisional Abutment
- Joint Strengths of Metal Framework Structures for Removable Partial Dentures
- Prosthesis Made of an Onlay-Type Rest with High Retentive Force (Cap Clasp)
- Statistical Evaluation of Titanium Metal Base Dentures Used in Vivo
- Comparison of the Attractive Forces of Dental Magnetic Attachments Fabricated by Cast- and Direct-Bonding Techniques
- Surface Analysis of Keepers on Dental Magnetic Attachments : Comparison of Cast-Bonding Technique and Direct-Bonding Technique
- Influence of Neuroticism on Denture Wear
- Implant Placement for Mandibular Overdentures using the Neutral Zone Concept
- Influence of denture treatment on brain function activity
- Survey on use of titanium dentures in Tsurumi University Dental Hospital for 11 years
- Clinical Evaluation of Porcelain Fused to Electroformed Gold Coping Crowns : Preliminary Results after 30-43 Months
- Prospective Clinical Study of Procera AllCeram Crowns : 2-3 year Preliminary Results
- Condition of depressive symptoms among Japanese dental students
- A New Retainer Using Magnetic Attachment
- Effects of argon gas flow rate on laser-welding
- Influence of thickness and undercut of thermoplastic resin clasps on retentive force
- Inhibitory effect of coated mannan against the adhesion of Candida biofilms to denture base resin
- Fabrication of fixed implant prostheses using function bite impression technique (FBI technique)
- Effect of implant support on mandibular distal extension removable partial dentures: Relationship between denture supporting area and stress distribution
- Evaluation of psychological effect of prosthetic treatment using Emotion Spectrum Analysis Method (ESAM)
- Long-term clinical evaluation of implant over denture