In order to improve the performance of a corona charger in charging the photoreceptor in electrophotography, the effect of an ultrasonic wave on the process was investigated experimentally. An ultrasonic wave of 28 kHz was supplied from an ultrasonic generator at five different strengths ranging from 0 to 50 W. Instead of a photoreceptor drum, a coated aluminum drum containing a thin insulator film was used in this study. It was confirmed that the ultrasonic wave had a marked effect on the charging performance of the corona charger; namely, the ultrasonic wave increased the charge density on the insulator layer of the drum. The charge density depended on the magnitude of the ultrasonic wave and the distance between the ultrasonic generator and the wire electrode. These results were attributed to the activation of the corona discharge by the ultrasonic wave and the blowing off of the suppression gas near the corona wire electrode by the ultrasonic wave.
- Published by the Japan Society of Applied Physics through the Institute of Pure and Applied Physicsの論文
- 2005-05-15
著者
-
Choi Kwang-seok
Faculty Of Science And Technology Tokyo University Of Science
-
Nakamura Satoshi
Faculty of Engineering, Kanazawa Institute of Technology
-
Murata Yuji
Faculty Of Science And Technology Science University Of Tokyo
-
Nakamura Satoshi
Faculty Of Science And Technology Tokyo University Of Science
-
Nakamura Satoshi
Faculty Of Bioscience And Biotechnology Tokyo Institute Of Technology
関連論文
- Effect of Hot Airflow on Charging Performance of Corona Charger in Electrophotography
- Universal Scaling Behavior of Dielectric Dispersion and Its Breakdown in Glycerol, Propyleneglycol and Trimethyleneglycol
- Atomic Force Microscopy of an Extremely Halophilic Archaeon Using Rapid Membrane Filtration
- Mechanism of Contact Charging of Photoconductive Layer for Electrophotography with DC-Biased Conductive Roller
- Improvement of Charging Performance of Corona Charger in Electrophotography by Irradiating Ultrasonic Wave to Surrounding Region of Corona Electrode
- Change in Charging Characteristics of High Polymers due to Plasma Treatment
- Short-Range Nature of Charge-Symmertry-Symmetry-Breaking Potential in Nuclear Force
- Effect of Hot Airflow on Charging Performance of Corona Charger in Electrophotography
- Change in Charging Characteristics of High Polymers due to Plasma Treatment