機器中性子放射化分析法による純鉄標準物質中のトランプ元素を中心とした微量元素 の定量
スポンサーリンク
概要
- 論文の詳細を見る
Trace tramp elements (Zn, As, Sn and Sb) and other trace elements in pure iron certified standard materials, JSS003-4, JSS168-7 and JSS172-7, prepared by the Iron and Steel Institute of Japan were determined by instrumental neutron activation analysis (INAA). Four aliquot samples of each certified standard material (ca. 100-450mg) were irradiated for 6h at a thermal neutron flux of 3.7×10^<12> ncm^<-2> in the Rikkyo University Research Reactor. The irradiated samples were measured by y-ray spectrometry using a coaxial Ge detector. The concentration of 3 elements (Co, Ni and As) in the JSS003-4, the concentration of 7 elements (Cr, Co, Ni, As, Mo, Sn and Sb) in JSS168-7 and the concentration of 7 elements (Cr, Co, Ni, As, Mo, Sb and Ta) in JSS172-7 were determined. The determined values were in good or nearly good agreement with the certified values or the reported values. The lower limit of determination values for the tramp elements were 0.01-0.1 μg/g Sb and As and 10-100 μ/g Zn and Sn respectively.
- 社団法人日本鉄鋼協会の論文
著者
関連論文
- 多重γ線放射化分析によるたたら製鉄試料中のヒ素とアンチモンの定量(分析・解析)
- 放射化学中性子放射化分析法による高純度鉄中の徴量ニッケル及びコバルトの同時定量
- 放射化学中性子放射化分析法による高純度鉄中の微量モリブデンの定量
- 放射化学中性子放射化分析法による高純度鉄標準物質中の微量モリブデンの定量
- 機器中性子放射化分析法による頭髪標準試料の多元素定量
- 二重中性子捕獲反応の影響がある中性子放射化分析における高純度二酸化ケイ素中のウラン及びトリウムの定量(:分離(その1))(予備濃縮分離)
- 093109 硬式テニスラケットのガット張力がプレーに及ぼす影響(9.体育方法,一般研究)
- 9034 テニスラケットの特性とプレー効果に関する研究 : ラケットサイズの違いと学習効果について(9.体育方法,一般研究)
- 日本分析化学会における標準物質の開発(分析の信頼性とバリデーション)
- 西本願寺境内より出土した鉄滓及び鉄塊の金属学的分析