Effect of Pre-Hydriding on Thermal Shock Resistance of Zircaloy-4 Cladding under Simulated Loss-of-Coolant Accident Conditions
スポンサーリンク
概要
- 論文の詳細を見る
Experiments simulating loss-of-coolant accident (LOCA) conditions were performed to evaluate the effect of pre-hydriding on the thermal-shock resistance of oxidized Zircaloy-4 cladding. Test rods fabricated with 580-mm long claddings were isothermally oxidized at temperatures ranging from 1,220 to 1,530 K in steam and then were quenched with flooding water. Both artificially hydrided (400 to 600 ppm) and non-hydrided claddings were subjected to these tests. Since cladding fracture on quenching primarily depends on the amount of oxidation, the fracture threshold was evaluated in terms of “equivalent cladding reacted (ECR).” Under an axially unrestrained condition, the fracture threshold is about 56% ECR, and the influence of pre-hydriding is not observed. The fracture threshold is decreased by restraining the test rods on quenching, and it is more remarkable in pre-hydrided claddings than in non-hydrided claddings. Consequently, the fracture threshold was about 20% ECR and 10% ECR for non-hydrided and pre-hydrided claddings, respectively, under the fully restrained condition. These results indicate a possible decrease of fracture threshold of high burn-up fuel claddings under LOCA conditions.
- 社団法人 日本原子力学会の論文
- 2004-07-25
著者
-
NAGASE Fumihisa
Japan Atomic Energy Agency
-
FUKETA Toyoshi
Japan Atomic Energy Agency
-
Nagase F
Japan Atomic Energy Research Institute
-
Fuketa Toyoshi
Japan Atomic Energy Research Institute
関連論文
- Identification of Radial Position of Fission Gas Release in High-Burnup Fuel Pellets under RIA Conditions
- Stress Intensity Factor at the Tip of Cladding Incipient Crack in RIA-Simulating Experiments for High-Burnup PWR Fuels
- Optimized Ring Tensile Test Method and Hydrogen Effect on Mechanical Properties of Zircaloy Cladding in Hoop Direction
- Behavior of High Burn-up Fuel Cladding under LOCA Conditions
- Evaluation of Initial Temperature Effect on Transient Fuel Behavior under Simulated Reactivity-Initiated Accident Conditions
- Clad-to-Coolant Heat Transfer in NSRR Experiments
- Radionuclide Release from Mixed-Oxide Fuel under High Temperature at Elevated Pressure and Influence on Source Terms
- Proposal of Simplified Model of Radionuclide Release from Fuel under Severe Accident Conditions Considering Pressure Effect
- Effects of Fuel Oxidation and Dissolution on Volatile Fission Product Release under Severe Accident Conditions
- Releases of Cesium and Poorly Volatile Elements from UO_2 and MOX Fuels under Severe Accident Conditions
- Fracture Behavior of Irradiated Zircaloy-4 Cladding under Simulated LOCA Conditions
- Behavior of Coated Fuel Particle of High-Temperature Gas-Cooled Reactor under Reactivity-Initiated Accident Conditions
- Behavior of 60 to 78MWd/kgU PWR Fuels under Reactivity-Initiated Accident Conditions
- Failure Thresholds of High Burnup BWR Fuel Rods under RIA Conditions
- Behavior of Irradiated ATR/MOX Fuel under Reactivity Initiated Accident Conditions
- Fission Gas Release Behavior of High Burnup UO_2 Fuel under Reactivity Initiated Accident Conditions
- Hydrogen Generation during Cladding/Coolant Interactions under Reactivity Initiated Accident Conditions
- Behavior of Pre-hydrided Zircaloy-4 Cladding under Simulated LOCA Conditions
- Thermal Stress Analysis of High-Burnup LWR Fuel Pellet Pulse-Irradiated in Reactivity-Initiated Accident Conditions
- Analysis of MOX Fuel Behavior in Halden Reactor by FEMAXI-6 Code
- Investigation of Hydride Rim Effect on Failure of Zircaloy-4 Cladding with Tube Burst Test
- Influence of Hydride Re-orientation on BWR Cladding Rupture under Accidental Conditions
- Influence of Cladding-Peripheral Hydride on Mechanical Fuel Failure under Reactivity-Initiated Accident Conditions
- Effect of Cladding Surface Pre-oxidation on Rod Coolability under Reactivity Initiated Accident Conditions
- RANNS Code Analysis on the Local Mechanical Conditions of Cladding of High Burnup Fuel Rods under PCMI in RIA-Simulated Experiments in NSRR
- Effect of Pre-Hydriding on Thermal Shock Resistance of Zircaloy-4 Cladding under Simulated Loss-of-Coolant Accident Conditions
- Effect of Cooling History on Cladding Ductility under LOCA Conditions
- Oxidation kinetics of Low-Sn Zircaloy-4 at the Temperature Range from 773 to 1, 573 K
- B_4C/Zircaloy Reaction at Temperatures from 1, 173 to 1, 953 K
- Oxidation kinetics of Low-Sn Zircaloy-4 at the Temperature Range from 773 to 1, 573 K
- Influence of Hydride Re-orientation on BWR Cladding Rupture under Accidental Conditions