Nitrogen Isotope Separation with Displacement Chromatography Using Cryptand Polymer
スポンサーリンク
概要
- 論文の詳細を見る
Chromatographic nitrogen isotope separation was experimentally studied in a break through manner. A solution of 0.4 mol·dm−3 NH4Cl in methanol was continuously fed at 0.12, 0.25 and 0.50cm3·min−1 into a glass tube packed with cryptand(2B,2,1) polymer. The temperature of column was kept constant at 293 K by passing temperature-controlled water through a jacket. Nitrogen gas was generated from the effluent reacted with Ca(ClO)2 solution after removing methanol by vacuum distillation, and the ratio of 14N15N to 14N14N was measured with a mass spectrometer (Finnigan MAT252). NH4Cl concentrations in the samples were gravimetrically determined. An enrichment factor, which is defined as an equilibrium separation factor minus unity was determined to be 0.0025±0.0013. A HETP (height equivalent to a theoretical plate) was evaluated 0.5±0.2 cm at 14 cm·h−1. This is the first report on nitrogen isotope separation with cryptand polymer.
- 一般社団法人 日本原子力学会の論文
- 2002-04-25
著者
-
Sugiyama Hiroshi
Department of Chemistry, Graduate School of Science Kyoto University
-
YAMAMOTO ICHIRO
Department of Pathology, Kitasato University School of Hygienic Sciences
-
Enokida Youichi
Department Of Nuclear Engineering Nagoya University
-
Sugiyama Hiroshi
Department Of Chemistry Graduate School Of Science Kyoto University
-
Yamamoto Ichiro
Department Of Chemistry Graduate School Of Science The University Of Tokyo
-
Sugiyama Hiroshi
Department Of Chemistry Faculty Of Science
-
Sugiyama Hiroshi
Department Of Nuclear Engineering Nagoya University
関連論文
- User-friendly Synthesis and Photoirradiation of a Flavin-linked Oligomer
- PJ-088 Development of synthetic pyrrole-imidazole polyamide targeting TGF-β1 as a novel gene therapy for vascular proliferative diseases and progressive renal diseases(Gene Therapy 1 (IHD) : PJ15)(Poster Session (Japanese))
- Pharmacokinetic Modeling and Prediction of Plasma Pyrrole-Imidazole Polyamide Concentration in Rats Using Simultaneous Urinary and Biliary Excretion Data
- 2P-112 BrG置換されたヒトテロメアDNAの単 : 分子FRET計測に基づくG-quadruplex立体構造の考察(核酸・構造物性,第46回日本生物物理学会年会)
- LYSOSOMAL ENZYMES IN HELA CELLS
- First Application of X-ray Refraction-based Computed Tomography to a Biomedical Object(Physiology)
- A Test of an X-Ray Quatrochrome Interferometer for Simultaneous Observation of Images Due to Dark-and Bright-Field, Phase-Interference and Absorption Contrasts
- Simple X-Ray Dark- and Bright-Field Imaging Using Achromatic Laue Optics : Instrumentation, Measurement, and Fabrication Technology
- 26aYA-12 Design and Performance of High Resolution Monolithic Monochromators
- Inhibition of MMP-9 transcription and suppression of tumor metastasis by pyrrole-imidazole polyamide