Amperometric Detection of Nitrogen Oxides by Means of Interdigitated Array Electrodes
スポンサーリンク
概要
- 論文の詳細を見る
The detection of nitrogen oxides contained in air was investigated using their redox cycles. NO and NO2 gases can be detected by means of interdigitated array (IDA) electrodes made of Au that are fabricated on a gas-permeable membrane. The IDA electrodes were applied to a gas detection system for the first time. Although the membrane is soft and flexible, and has pores, the electrodes can be formed successfully on it by photolithography devised in our laboratory. Between the electrodes, redox cycles are produced, and, hence, the gas sensitivities increase. The reactions in this redox cycles are not simple, and it was confirmed that nitrate produced on the generator electrode reacts with NO gas on the collector in the NO detection system. The increase in sensitivity based on the generation of the redox cycle in amperometric detection appears to be improved by decreasing the distance between the electrodes.
- Japan Society for Analytical Chemistryの論文
- 1997-12-01
著者
-
戸田 敬
熊本大学理学部環境理学科
-
Toda Kei
Department Of Environmental Science Faculty Of Science Kumamoto University
-
Toda Kei
Department Of Chemistry Faculty Of Science Kumamoto University
-
OGUNI Seiki
Department of Environmental Science, Faculty of Science, Kumamoto University
-
HASHIGUCHI Shuichi
Department of Environmental Science, Faculty of Science, Kumamoto University
-
SANEMASA Isao
Department of Environmental Science, Faculty of Science, Kumamoto University
-
Oguni Seiki
Department Of Environmental Science Faculty Of Science Kumamoto University
-
実政 勲
Department Of Environmental Science Faculty Of Science Kumamoto University
-
Sanemasa Isao
Department Of Chemistry Faculty Of Science Kumamoto University
-
Hashiguchi Shuichi
Department Of Environmental Science Faculty Of Science Kumamoto University
関連論文
- 阿蘇山及び熊本市における大気中二酸化硫黄及び硫化水素の長期モニタリングとモバイル調査
- Miniature Liquid Flow Sensor and Feedback Control of Electroosmotic and Pneumatic Flows for a Micro Gas Analysis System
- フロー分析における小型キーデバイスの開発と応用
- Trends in Atmospheric Trace Gas Measurement Instruments with Membrane-based Gas Diffusion Scrubbers
- 液滴マイクロリング電極による電気化学的ガス計測方法の検討 (ダウンサイズ化する分析化学)
- A Planar Gas Sensor Combined with Interdigitated Array Electrodes
- 亜硫酸ガスの高感度マイクロ検出器
- フロー式溶液導電率法に基づく二酸化硫黄の小型検出器
- Amperometric Detection of Nitrogen Oxides by Means of Interdigitated Array Electrodes
- 疎水性樹脂カラムを用いる金属ポルフィリンの錯形成時及び金属置換反応時における中間体の会合定数の測定
- 金属-チタン酸化物によるガス状水素化物の検出(センサー)
- 接触反応を用いるフッ化物イオンのフローインジェクション法
- ポリテトラフルオロエチレンフィルムによる水溶液中の無電荷金属錯体の濃縮
- 水溶液中での単体水銀とシクロデキストリンとの会合
- クロロホルム蒸気通気による水溶液中の疎水性溶質のポリテトラフルオロエチレンフィルム表面への濃縮
- コバルト(II)によるスチルバゾの接触酸化反応を利用する過酸化水素のフローインジェクション分析法
- 陰イオン交換樹脂による前濃縮を併用した微分パルスアノーディックストリッピングボルタンメトリーによる極微量カドミウムの定量
- イオンクロマトグラフィー用分離カラムの簡便な調製法
- フローインジェクション法による極微量ヨウ化物イオンの接触分析定量
- 希土類元素イオンの酢酸-水-フェノール-オキシン系溶媒における分配挙動
- ランタン,ユウロピウム,イッテルビウムの空気-アセチレンフレームによるフレーム分光分析
- Improvement in Reliability of Probabilistic Test of Significant Differences in GeneChip Experiments
- 火山ガス観測よりみた最近の桜島と阿蘇(日本火山学会 1979 年秋季大会講演要旨)
- Test of Significant Differences with a priori Probability in Microarray Experiments
- Determination of Nitrite by Flow Injection Spectrophotometry Using a Home-made Flow Cell Detector
- Highly Sensitive Flow Analysis of Trace Level Arsenic in Water Based on Vaporization-collection In-line Preconcentration
- Double Schottky Diode-Type Gas Sensor for Discriminative Detection of Phosphine and Hydrogen
- Association of n-Alcohol with p-Sulfonato Calixarenes in an Aqueous Medium Determined by Headspace Gas Chromatography
- Association of Alcohol-Cyclodextrin in Aqueous Medium Determined by Headspace Gas Chromatography
- Association Constants of Ferrocene with Cyclodextrins in Aqueous Medium Determined by Solubility Measurements of Ferrocene
- Cyclodextrin Precipitates with Normal Alcohols in an Aqueous Medium and Their Stability on Being Left Standing in Air
- Solubility Product and Solubility of Cyclodextrin Inclusion Complex Precipitates in an Aqueous Medium
- Isomer Compositions of Trimethyl-or Trichlorobenzenes in α-Cyclodextrin Precipitates Formed in an Aqueous Medium
- Uptake of Cycloalkanes and Bicyclic Aromatic Compounds by Ion-Exchange Resins from Aqueous Solutions
- Uptake of Iodine and Bromine by Ion-Exchange Resins in Aqueous Solution
- 森林大気中イソプレンと関連物質のオンサイト多成分分析
- Concentration on Glass Separatory Funnel Wall of Anionic Surfactants by Ion Association with Methylene Blue
- Electrochemical Flow Enzyme Immunoassay by Means of a Needle-Shaped Sampler/Reactor
- Uptake of Benzene and Alkylbenzenes by Cation- and Anion-Exchange Resins from Aqueous Solutions
- 'シンク効率'を指標とした固相吸着剤の硫化水素吸着特性に関する動的評価 : リモナイトなどの脱硫特性を例に
- High Sensitivity Arsenic Analyzer Based on Liquid-reagent-free Hydride Generation and Chemiluminescence Detection for On-site Water Analysis
- Uptake of Alkanes and Alcohols by Ion-Exchange Resins in Aqueous Solution
- 疎水性溶質とシクロデキストリンとの会合
- 46. 1974年阿蘇火山活動の〓出物中の水銀(日本火山学会1978年秋季大会)
- 水溶液中での水銀の溶解度(II.陸水の重金属汚染)
- Determination of Histamine in Seafood by Hydrophilic Interaction Chromatography/Tandem Mass Spectrometry
- The solubility of benzene-hydrocarbon binary mixtures in water.
- Solubility measurements of benzene and the alkylbenzenes in water by making use of solute vapor.
- The solubility and cyclodextrin complexations of fluorene, fluoranthene, and pyrene in aqueous medium.
- Equilibrium solubilities of benzene, toluene, ethylbenzene, and propylbenzene in silver nitrate solutions.
- Association of C5-C9 normal alkanes with cyclodextrins in aqueous medium.
- Measurements of association constants of iodine with cyclodextrins and with iodide or bromide ion in aqueous medium, based on volatilization rate of iodine from aqueous into gaseous phase.
- Association of naphthalene and its methyl derivatives with cyclodextrins in aqueous medium.
- Association of Cycloalkanes with Cyclodextrins in Aqueous Medium.
- Application of gel chromatography to determing formation constants of inclusion compounds of cyclodextrins.