Nonlinearity Parameter Measurement for Polymer Plates Using Focused Ultrasound
スポンサーリンク
概要
- 論文の詳細を見る
The measurement of the acoustic nonlinearity parameter $B/A$ based on the finite amplitude method for a 1-mm-thick polymer plate which is put, together with a sound reflector set at the back, within the focal region of 18.6 MHz focused ultrasound yields extraordinary $B/A$ values as large as 26.6, for example, in polystyrene. The experiment also demonstrates the velocity dispersion in the sample as well as the multiple reflections within the gap between the sample and sound reflector. They both make the second harmonic component advance relative to the fundamental, and then enhance the second harmonic component by suppressing the phase delay due to diffraction. Recalculating $B/A$ by taking these effects into consideration, reasonable values such as 11.4 in polystyrene are obtained. The $B/A$ values in other polymer plates with stronger dispersion are estimated in a similar manner to reveal reasonable values.
- Published by the Japan Society of Applied Physics through the Institute of Pure and Applied Physicsの論文
- 2008-09-25
著者
-
Saito Shigemi
School Of Marine Science And Technology Tokai University
-
Motohashi Yoshiro
School of Marine Science and Technology, Tokai University, Orido, Shimizu-ku, Shizuoka 424-8610, Japan
関連論文
- Multiple-frequency ultrasonic imaging by transmitting pulsed waves of two frequencies
- Numerical Calculation and Measurement of Nonlinear Acoustic Fields in Ultrasound Diagnosis
- High frequency focusing Gaussian source intended for B/A imaging
- Experiment on Acoustic Field of Parametric Focusing Source
- P3-9 Measurement of the Acoustic Property of Small Volume Liquid Sample beyond Acoustic Window(Poster session 3)
- Measurement of longitudinal attenuation coefficient in human hair
- $B/A$ Measurement for Liquid Media Using an LN Transducer with Inverted-Domain Layer
- Development of an ultra-broadband ultrasonic imaging system : prototype mechanical sector device
- Nonlinearly generated second harmonic sound in a focused beam reflected from free surface
- Speckle Noise Reduction by Superposing Many Higher Harmonic Images
- Measurement of Acoustic Property of Small-Volume Liquid Sample beyond Acoustic Window
- Modified Ultrasound Source for Long Focused Second Harmonic Beam
- Measurement of Acoustic Nonlinearity Parameter of Small-Volume Liquid Sample Using Focused Ultrasound
- Measurement of Sound Speed in Thread
- Design of Fiber-Optic Magnetometer Utilizing Magnetostriction
- Nonlinearity Parameter Measurement for Polymer Plates Using Focused Ultrasound