Modified Ultrasound Source for Long Focused Second Harmonic Beam
スポンサーリンク
概要
- 論文の詳細を見る
With the aim of avoiding the concentration of second harmonic generation at the focus, a modified focusing source designed to minimize the fundamental amplitude at the focus is examined. The present source consists of two coaxially arranged confocal transducers: An inner disk transducer and an outer ring transducer whose areas are the same. They have been polarized in the thickness direction opposite to each other, and are connected in parallel. The theoretical and experimental results show that the second harmonic amplitude attains a maximum at three locations including two positions where the fundamental amplitude takes peak values. A relatively sharp second harmonic beam is demonstrated. Provided the radius of curvature is relatively small, since the three maximum positions are close to each other, the second harmonic beam effectively focuses long. Suppression of side lobes by weighting the source excitation is also discussed.
- Published by the Japan Society of Applied Physics through the Institute of Pure and Applied Physicsの論文
- 2004-05-15
著者
-
Saito Shigemi
School Of Marine Science And Technology Tokai University
-
KAWAGISHI Tetsuya
Toshiba Medical Systems Corporation
-
Kawagishi Tetsuya
Toshiba Medical Systems, Shimoishigami, Otawara 324-8550, Japan
関連論文
- Multiple-frequency ultrasonic imaging by transmitting pulsed waves of two frequencies
- Numerical Calculation and Measurement of Nonlinear Acoustic Fields in Ultrasound Diagnosis
- High frequency focusing Gaussian source intended for B/A imaging
- Practical considerations for a method of rapid cardiac function analysis based on three-dimensional speckle tracking in a three-dimensional diagnostic ultrasound system
- Experiment on Acoustic Field of Parametric Focusing Source
- P3-9 Measurement of the Acoustic Property of Small Volume Liquid Sample beyond Acoustic Window(Poster session 3)
- Measurement of longitudinal attenuation coefficient in human hair
- $B/A$ Measurement for Liquid Media Using an LN Transducer with Inverted-Domain Layer
- Development of an ultra-broadband ultrasonic imaging system : prototype mechanical sector device
- Nonlinearly generated second harmonic sound in a focused beam reflected from free surface
- Speckle Noise Reduction by Superposing Many Higher Harmonic Images
- Measurement of Acoustic Property of Small-Volume Liquid Sample beyond Acoustic Window
- Modified Ultrasound Source for Long Focused Second Harmonic Beam
- Measurement of Acoustic Nonlinearity Parameter of Small-Volume Liquid Sample Using Focused Ultrasound
- Measurement of Sound Speed in Thread
- Design of Fiber-Optic Magnetometer Utilizing Magnetostriction
- Nonlinearity Parameter Measurement for Polymer Plates Using Focused Ultrasound