Comparison of SPAMM and SENC Methods for Evaluating Peak Circumferential Strain at 3T
スポンサーリンク
概要
- 論文の詳細を見る
We compared peak circumferential strain (Ecc) values with spatial modulation of magnetization (SPAMM) and strain-encoded (SENC) magnetic resonance (MR) imaging at 3 tesla. Correlation coefficients of the averaged peak Ecc values of the 2 methods were statistically significant. However, the average peak Ecc value was significantly lower with SPAMM (−13.5%±3.3%) than with SENC (−21.6%±3.4%) (P<0.0001). The SENC method showed higher circumferential strain than the SPAMM method at 3T.
著者
-
Hamaguchi Hiroyuki
Department Of Hematology And Oncology Musashino Red Cross Hospital
-
Sugimori Hiroyuki
Department Health And Physical Education Faculty Of Education Gifu University
-
Ishizaka Kinya
Department Of Diagnostic And Interventional Radiology Hokkaido University Hospital
-
Oyama-Manabe Noriko
Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital
-
HAMAGUCHI Hiroyuki
Department of Radiological Technology, Hokkaido University Hospital
-
SUGIMORI Hiroyuki
Department of Radiological Technology, Hokkaido University Hospital
-
SAKATA Motomichi
Graduate School of Health Sciences, Hokkaido University
-
Oyama-Manabe Noriko
Department of Diagnostic and Interventional Radiology, Hokkaido University Graduate School of Medicine
-
HAMAGUCHI Hiroyuki
Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital
関連論文
- PJ-247 Phase-sensitive Reconstruction Method Secures Well-defined Myocardial Delayed Enhancement in MR Imaging in Patients with Cardiomyopathy(MRI/MRA-4 (I) PJ42,Poster Session (Japanese),The 70th Anniversary Annual Scientific Meeting of the Japanese Circ
- OJ-126 Delayed Enhancement of Cardiovascular MRI Points out the Longest QT Interval Lead Producing Wide QT Dispersion in Hypertrophic Cardiomyopathy(ECG/Body surface potential mapping/Holter-2 (A) OJ21,Oral Presentation (Japanese),The 70th Anniversary Ann
- Clinical features of adult acute leukemia with 11q23 abnormalities in Japan : a co-operative multicenter study
- Age-related changes in the hemodynamics of the femoral head as evaluated by early phase of bone scintigraphy
- Supplying water to participants in midsummer kendo training camp : A study on the prevention of heat illnesses
- Design and Fabrication of a Differential Capacitive Three-Axis SOI Accelerometer Using Vertical Comb Electrodes
- Localized Small-Bowel Infarction Caused by Aspergillus During Chemotherapy for Acute Myeloid Leukemia : Report of a Case
- Analysis of Triglyceride Value in the Diagnosis and Treatment Response of Secondary Hemophagocytic Syndrome
- Cobalt-catalyzed Cross-coupling Reactions of Aryl Bromides with Alkyl Grignard Reagents
- CD7^+ Near-Tetraploid Acute Myeloblastic Leukemia M2 With Double t(8;21)(q22;q22) Translocations and AML1/ETO Rearrangements Detected by Fluorescence In Situ Hybridization Analysis
- Comparison of ^1H MR Spectroscopy, 3-point DIXON, and Multi-echo Gradient Echo for Measuring Hepatic Fat Fraction
- Diffusion Tensor Imaging Characteristics of Normal Human Cervical Spinal Cord at 3T
- Lower aerobic capacity was associated with abnormal intramuscular energetics in patients with metabolic syndrome
- Comparison of SPAMM and SENC Methods for Evaluating Peak Circumferential Strain at 3T
- Laterality of the Corticospinal Tract and the Influence of Handedness : Findings of a DTI Study
- Cardiac Magnetic Resonance Performs Better in the Detection of Functionally Significant Coronary Artery Stenosis Compared to Single-Photon Emission Computed Tomography and Dobutamine Stress Echocardiography
- Comparison of SPAMM and SENC Methods for Evaluating Peak Circumferential Strain at 3T