経頭蓋的超音波検査 (B-mode) の頭蓋内解剖学的所見と臨床への応用性について
スポンサーリンク
概要
- 論文の詳細を見る
Transcranial sonography is anticipated to be a convenient method for clinical diagnosis, and evaluation of therapeutic progress. Another modality, three-dimensional power Doppler (also known as 3-dimensional color power angio: 3D CPA), is now being used to visualize intracranial vascular structures in a similar way to cerebral angiography.<BR>Recently, there have been some reports on the detection of cerebral aneurysms by transcranial sonography with the use of contrast medium, although this approach is not good enough for clinical diagnosis. However, we have used this method mainly for detecting intraoperative vascular structures, especially cerebral aneurysms, and found that the results have been as good as intraoperative angiography.<BR>Another modality is transcranial harmonic imaging using gastrointestinal area that has been suggested to be useful for diagnosis of cerebral ischemic diseases and brain tumors. Postert and Seidel have already reported the application of this method for studying normal volunteers and patients with cerebral infarction at the early stage. Thus it is anticipated that transcranial sonography may be as useful as CT, MRI and cerebral angiography for intracranial imaging diagnosis. In the future, transcranial sonography may be used for intracranial diagnosis of conditions such as cerebral aneurysm, cerebral ischemic disease, and brain tumors. However, this method has several imaging characteristics and technical problems. One is variability of the slice level. Our method of transcranial sonography is restricted to a temporal bone window and sometimes a frontal bone window. Furthermore, the size of the bone window varies among different patients, so the images obtained change according to the patient and the degree of ultrasound attenuation through the bone. Furthermore the examiners using this technique need to be experienced and skillful. Because of these problems, transcranial B-mode imaging has been mainly employed.<BR>Standard images obtained with transcranial sonographic B-mode have not been reported up to now. The further development of transcranial sonographic instruments should make it possible to obtain intracranial images showing anatomical structures, such as the third ventricle, midbrain, lateral ventricle (anterior, posterior and inferior horns, body), cistern, and intracranial bone structures, allowing correct understanding of intracranial position by transcranial sonography. This will undoubtedly be useful for further clinical application to intracranial diseases. It is anticipated that this report will be helpful for interpreting transcranial sonographic images.
著者
関連論文
- 42 確実な脳室穿刺のためのBurr hole buttonの開発(北日本脳神経外科連合会第28回学術集会)
- Volume imaging 法による3次元超音波検査について : 周術期における頭蓋内3D超音波画像
- venous angioma 32例の検討-MRI所見と症状発現機転について
- プラークにおける灌流検査 : 造影超音波検査法の応用
- 頸動脈プラーク病変における新生血管について : 新画像法から
- 脳動脈瘤手術における術中超音波検査の有用性について : 三次元超音波検査(3DCPA)とAdaptive Filter Imaging法(XRES)から(脳卒中の外科における合併症の予防と対策)
- 頸動脈狭窄病変における新生血管の意義 : Pulse Inversion Harmonic Imaging法の下で超音波造影剤を使用
- 頭蓋内腫瘍及び腫瘤性病変の経頭蓋的及び術中超音波検査について : Pulse Inversion Harmonic Imaging method 下で超音波造影剤を使用して
- 脳動脈瘤術中における超音波検査 : パワードプラ法による3次元脳血管撮影(Three Dimensional Color Power Angio)の有用性
- 外傷性頭蓋内椎骨動脈と脳底動脈閉塞症の1例
- 内視鏡的脳内血腫除去術が困難であったmicroAVMの1例
- なーしんぐ・すぽっと 除毛剤を用いた頭部部分剃毛の試み
- 椎骨動脈系の血流不全によるめまい症状と考えられた症例の椎骨動脈 1st segment における, 頸部運動に伴う血管形態と血行動態の変化について : Color Doppler Flow Image と 3 Dimensional Color Power Angio による
- 定位的脳内血腫除去術例における血腫周辺脳組織血液潅流の経時的変化について : —超音波造影剤を使用したPulse Inversion Harmonic Imaging法を使用して—
- Inversion Recovery 併用T_1強調 -3D Variable Refocus Flip Angle Turbo Spin Echo (SPACE)Black Blood Imaging の頸動脈プラーク検査への応用
- 中大脳動脈M2部以遠の遠位塞栓に対する機械的再開通法
- 経頭蓋的超音波検査 (B-mode) の頭蓋内解剖学的所見と臨床への応用性について
- ガラクトース製剤の懸濁液 (Levovist, Schering AG) を用いた経頭蓋超音波検査による Perfusion image について
- PICA-involved typeの破裂解離性椎骨動脈瘤に対する急性期血管内治療の1例:-PICAを温存した部分的trapping-