酸化トリオクチルホスフィン抽出法を用いる電気炉ダスト中の亜鉛のキレート滴定法
スポンサーリンク
概要
- 論文の詳細を見る
A method for the determination of zinc in dust by chelatometric titration after an extraction with TOPO-benzene was presented. <BR>The sample was taken up with hydrochloric acid and hydrogen peroxide. The acid concentration was adjusted to 1.53.0<I>N</I>, and ferric iron was reduced to ferrous by ascorbic acid. Thirty milliliters of the benzene solution of 0.1<I>M</I> TOPO was added, and zinc was extracted by 3 min. shaking. The aqueous layer was separated, and 20 m<I>l</I> of perchloric acid (1 + 15) was added to the organic layer for back-extracting zinc by 1 min. shaking. Hydrogen peroxide, ammonium fluoride and sodium thiosulfate were added to the back-extracted layer for masking, respectively, traces of Fe<SUP>2+</SUP>, Al<SUP>3+</SUP> and Cu<SUP>2+</SUP>. After the adjustment of pH with hexamine, zinc was titrated with 0.02<I>M</I> EDTA solution by using XO as an indicator. Zinc in dust was determined in 40 min. with sufficienc accuracy and reproducibility.
- 社団法人 日本分析化学会の論文
著者
関連論文
- 酸化トリオクチルホスフィン抽出法を用いる電気炉ダスト中の亜鉛のキレート滴定法
- 酸化トリオクチルホスフィン抽出法を用いるアルミニウム合金中の亜鉛のキレート滴定法
- ナトリウムイオン濃度計によるナトリウムの定量
- モリブデン青の酸化滴定によるケイ素定量法の試み
- 抽出法を用いる精製チタン白中の微量鉄の吸光度定量
- EDTA-H2O2発色法によるアルミニウム合金中の鉄の迅速吸光光度定量