塩化ナトリウム,カリウム溶融による酸化マンガン(IV)と共存する酸化クロム(III)の選択的酸化と検出(ノート)
スポンサーリンク
概要
- 論文の詳細を見る
In general chromium sample is trivalent state and is detected as chromic acid, and in the presence of manganese, it should be bivalent for permanganate interferes the detection of chromate especially by diphenylcarbazide. Therefore, the selective oxidation of chromium in the presence of manganese is necessitated for this purpose.<BR>In this study, the sample which contains chromium(III) oxide and manganese (IV) oxide was mixed in a porcelain crucible with the flux which was prepared 1 mol sodium chloride and 1 mol potassium chloride, and heated to fuse. Chromium(III) was oxidized to chromium(VI) and manganese(IV) changed to manganese(II). The fused substance was extracted by water and chromium was detected by diphenylcarbazide. Limit of dectection of chromium was 2μg in 0.5 g manganese(IV) oxide.<BR>This chloride fusion method is superior to the sodium-potassium carbonate fusion which oxidizes both of chromium and manganese, and also superior to acid dissolving method in which simple selective oxidation of chromium was not known.
- 社団法人 日本分析化学会の論文
著者
関連論文
- 硫酸セリウム(III)によるヘキサフルオロケイ酸の検出および沈でん滴定
- オキシヒドロキノンによるガリウム,インジウムおよびタリウムの検出
- 同族元素の原子番号と酸化力との関係
- 硝酸バリウム融解による有機化合物中のイオウの検出
- 硫酸マンガンとして遊離イオウの検出(ノート)
- 塩化ナトリウム,カリウム溶融による酸化マンガン(IV)と共存する酸化クロム(III)の選択的酸化と検出(ノート)
- ハロゲン化物の乾式判別
- フェノールによるウランの検出(ノート)
- 酸化マンガン(4)による過ヨウ素酸の検出(ノート)
- 鉄(II)-ジメチルグリオキシムによるニトロ化合物の確認(ノート)