硝酸バリウム融解による有機化合物中のイオウの検出
スポンサーリンク
概要
- 論文の詳細を見る
Some type of sulfur in organic compounds is not able to be reduced to sulfide by metallic sodium or by sodium formate fusion, while all type of organic sulfur is readily oxidized to stable sulfuric acid by acidic oxidizing reagents. As the reagent for acidic fusion, barium nitrate is most suitable because it melts at such a low-temperature as 592°C and it has an oxidizing power. A small amount of solid sample is brought into a test tube, or a drop of sample solution is evaporated in a test tube and then the sample or the residue mixed well with about 0.5 g of barium nitrate. The tube is gradually warmed to red heat, and then cooled in water. The residue is added to hydrochloric acid and then the solution is boiled. White barium sulfate precipitate appears if sulfur is present in the sample.
- 社団法人 日本分析化学会の論文
著者
関連論文
- 硫酸セリウム(III)によるヘキサフルオロケイ酸の検出および沈でん滴定
- オキシヒドロキノンによるガリウム,インジウムおよびタリウムの検出
- 同族元素の原子番号と酸化力との関係
- 硝酸バリウム融解による有機化合物中のイオウの検出
- 酸化バメナジウム(5)融解による有機化合物中の諸元素の検出
- 硫酸マンガンとして遊離イオウの検出(ノート)
- 塩化ナトリウム,カリウム溶融による酸化マンガン(IV)と共存する酸化クロム(III)の選択的酸化と検出(ノート)
- ハロゲン化物の乾式判別
- フェノールによるウランの検出(ノート)
- 酸化マンガン(4)による過ヨウ素酸の検出(ノート)
- 鉄(II)-ジメチルグリオキシムによるニトロ化合物の確認(ノート)