Hydrolytic desulfonation of cation exchange resins in high temperature water.
スポンサーリンク
概要
著者
-
Uchida Shunsuke
Energy Research Laboratory Hitachi Ltd.
-
Asakura Yamato
Energy Research Laboratory Hitachi Ltd.
-
KARASAWA Hidetoshi
Energy Research Laboratory Hitachi Ltd.
関連論文
- Evaluation Methods for Corrosion Damage of Components in Cooling Systems of Nuclear Power Plants by Coupling Analysis of Corrosion and Flow Dynamics (IV) : Comparison of Wall Thinning Rates Calculated with the Coupled Model of Static Electrochemical Analy
- Evaluation Methods for Corrosion Damage of Components in Cooling Systems of Nuclear Power Plants by Coupling Analysis of Corrosion and Flow Dynamics (III) : Evaluation of Wall Thinning Rate with the Coupled Model of Static Electrochemical Analysis and Dyn
- Evaluation Methods for Corrosion Damage of Components in Cooling Systems of Nuclear Power Plants by Coupling Analysis of Corrosion and Flow Dynamics (II) : Evaluation of Corrosive Conditions in PWR Secondary Cooling System
- Evaluation Methods for Corrosion Damage of Components in Cooling Systems of Nuclear Power Plants by Coupling Analysis of Corrosion and Flow Dynamics (I) : Major Targets and Development Strategies of the Evaluation Methods
- Application of In-Service Temperature Lowering to Reduce Radioactivity Corrosion Product Deposition on Carbon Steel Piping of BWR Residual Heat Removal System
- Effects of Hydrogen Peroxide on Corrosion of Stainless Steel, (IV) : Determination of Oxide Film Properties with Multilateral Surface Analyses
- Effects of Hydrogen Peroxide on Corrosion of Stainless Steel, (III) : Evaluation of Electric Resistance of Oxide Film by Equivalent Circuit Analysis for Frequency Dependent Complex Impedances
- Effects of Hydrogen Peroxide on Corrosion of Stainless Steel, (II) : Evaluation of Oxide Film Properties by Complex Impedance Measurement
- Effects of Hydrogen Peroxide on Corrosion of Stainless Steel, (I) : Improved Control of Hydrogen Peroxide Remaining in a High Temperature High Pressure Hydrogen Peroxide Loop
- Water Chemistry in a Crack Tip under Irradiation, (I) Evaluation of Gamma-ray Energy Deposition in a Crack Tip
- Effects of Hydrogen Peroxide on Intergranular Stress Corrosion Cracking of Stainless Steel in High Temperature Water, (IV) Effects of Oxide Film on Electrochemical Corrosion Potential
- Effects of Hydrogen Peroxide on Intergranular Stress Corrosion Cracking of Stainless Steel in High Temperature Water, (III)Crack Growth Rates in Corrosive Environment Determined by Hydrogen Peroxide
- Effcts of Hydrogen Peroxide on Intergranular Stress Corrosion Cracking of Stainless Steel in High Temperature Water, ( II ) Optimization of Crack Propagation Rate Measurement System
- Effects of Hydrogen Peroxide on Corrosion of Stainless Steel (VI) : Effects of Hydrogen Peroxide and Oxygen on Anodic Polarization Properties of Stainless Steel in High Temperature Pure Water
- Effects of Hydrogen Peroxide on Corrosion of Stainless Steel, (V) Characterization of Oxide Film with Multilateral Surface Analyses
- Effects of Hydrogen Peroxide on Intergranular Stress Corrosion Cracking of Stainless Steel in High Temperature Water, (V) : Characterization of Oxide Film on Stainless Steel by Multilateral Surface Analyses
- Mitigation Effect of Alkaline Water Chemistry upon Intergranular Stress Corrosion Cracking of Sensitized 304 Stainless Steel
- Effects of Hydrogen Peroxide on Cobalt Deposition Rate on Primary Cooling System of Boiling Water Reactors
- Effects of Hydrogen Peroxide on Radioactive Cobalt Deposition on Stainless Steel Surface in High Temperature Water
- Determination of Hydrogen Peroxide in Water by Chemiluminescence Detection, (I) : Flow Injection Type Hydrogen Peroxide Detection System
- Determination of Hydrogen Peroxide in Water by Chemiluminescence Detection, (II) : Theoretical Analysis of Luminol Chemiluminescence Processes
- Water Chemistry in a Crack Tip under Irradiation, (II) Evaluation of Oxidant Concentration in the Crack Tip
- Water Chemistry Data Acquisition, Processing, Evaluation and Diagnostic Systems in Light Water Reactors
- Evaluation of Effectiveness of Hydrogen Water Chemistry for Different Types of Boiling Water Reactors
- Empirical Understanding of the Dependency of Hydrogen Water Chemistry Effectiveness on BWR Designs
- The Luminescence from a Long Lasting Phosphor Exposed to Alpha, Beta, and Gamma Rays
- Effects of Hydrogen Peroxide on Intergranular Stress Corrosion Cracking of Stainless Steel in High Temperature Water, (I), Effects of Hydrogen Peroxide on Electrochemical Corrosion Potential of Stainless Steel
- Evaluation Methods for Corrosion Damage of Components in Cooling Systems of Nuclear Power Plants by Coupling Analysis of Corrosion and Flow Dynamics (V) Flow-Accelerated Corrosion under Single- and Two-phase Flow Conditions
- Effects of Organic Impurities on BWR Water Chemistry, (2) Effects on Shutdown Dose Rate
- Evaluation of Leachable Behavior from Ion Exchange Resins Effects of Organic Impurities on BWR Water Chemistry, (1)
- A Mechanism for Corrosion Product Deposition on the Carbon Steel Piping in the Residual Heat Removal System of BWRs
- Noncontact Measurement of Film Thickness by the Photothermal Deflection Method
- Adsorption of Cobalt Ions on Hematite Particles
- Structural Material Anomaly Detection System Using Water Chemistry Data, (VIII). Water Chemistry Simulator and Its Application to Resin Intrusion.:Water Chemistry Simulator and Its Application to Resin Intrusion
- Structural Material Anomaly Detection SystemUsing Water Chemistry Data, (VII). Diagnosing Causes of Small Changes in Water Chemistryby Analyzing On-Line Conductivity and pH Data.:Diagnosing Causes of Small Changes in Water Chemistry by Analyzing On-Line C
- Chemical state and deposition rate of nickel ion deposit produced on heated surface in high pressure boiling water.
- Radiolytic environments in boiling water reactor cores.
- Structural material anomaly detection system using water chemistry data. II Prediction model of dose rate around recirculation pipes in iron crud suppressed BWR.:Prediction Model of Dose Rate around Recirculation Pipes in Iron Crud Suppressed BWR
- Radiolysis of N2-H2O systems.
- Water quality control at primary cooling system of crud concentration suppressed boiling water reactor. II Evaluation of cobalt-58 behavior in iron crud suppressed BWR.:Evaluation of Cobalt-58 Behavior in Iron Crud Suppressed BWR
- Experimental evaluation of improved dual temperature hydrogen isotopic exchange reaction system.
- Chemical composition of crud depositing on BWR fuel surfaces.
- Structural material anomaly detection system using water chemistry data. (III). In-line monitors for electrical conductivity of high temperature water.:In-Line Monitors for Electrical Conductivity of High Temperature Water
- Experimental Evaluation of Release Rates of Cobalt Ions from Cobalt Oxides at 285°C
- Hydrolytic desulfonation of cation exchange resins in high temperature water.
- Numerical analysis of hydrogen isotope separation characteristics in improved dual temperature exchange reaction system between water and hydrogen gas.
- BWR plants with low shutdown radiation level. Design and construction of plants and current experience with occupational exposure of plants.:Design and Construction of Plants and Current Experience with Occupational Exposure of Plants
- Pressure balanced type membrane covered polarographic oxygen detector for use in high temperature-high pressure water.
- Pressure balanced type membrane covered polarographic oxygen detectors for use in high temperature-high pressure water, (I) Application of guard electrode to improve detector performance at temperatures above 200.DEG.C.:Application of Guard Electrode to I
- Effects of crud diameter on shutdown dose rate of recirculation pipes in boiling water reactors.
- Water quality control in primary cooling system of crud concentration suppressed boiling water reactor. I Water chemistry experience in latest crud conentration suppressed BWR.:Water Chemistry Experience in Latest Crud Conentration Suppressed BWR
- Stability of catalytic activity in platinum impregnated porous teflon.
- Structural material anomaly detection system using water chemistry data. (I) Basic structure of anomaly detection system and its application for fuel defect detection.:Basic Structure of Anomaly Detection System and Its Application for Fuel Defect Detecti
- Temperature dependence of cobalt release rate from stainless steel in neutral water.
- Estimation of shutdown dose rate around recirculation pipes during operating life of boiling wate reactors.