Method for Assessing Neutron Dose Equivalent Rate in Operational Health Physics
スポンサーリンク
概要
- 論文の詳細を見る
Many types of survey instruments for measuring exposure dose from neutrons and methods for assessing the dose equivalent rate have been developed in many countries. In JAERI, extensive efforts have been made for establishing the method to assess neutron dose equivalent.<BR>The main objectives of this report are to introduce the principle of measuring neutron dose equivalent rate based on an orthonormal expansion method and to describe its application for the operational health physics in JAERI.<BR>This report also describes an experience with the various types of neutron survey instruments which have been employed for the radiation protection in JAERI since 1958.
- 日本保健物理学会の論文
著者
-
南 賢太郎
日本原子力研究所保健物理部線量計測課
-
吉田 芳和
日本原子力研究所保健物理安全管理部
-
福田 整司
日本原子力研究所
-
福田 整司
日本原子力研究所大洗研究所安全管理課
-
吉田 芳和
日本原子力研究所
-
南 賢太郎
日本原子力研究所
-
南 賢太郎
日本原子力研究所大洗研究所安全管理課
関連論文
- 個人線量計国際相互比較
- 原子炉事故時における日本の典型的な家屋の放射線遮蔽効果
- 各種建築材料のγ線減弱係数および線量ビルドアップ係数
- 着用時における浄気式全面, 半面マスクの防護性能
- BWR運転時の放射性気体廃棄物の放出基準の検討
- X線回折装置の放射線防護
- タイトル無し
- Collection Efficiency of Air Sampling Filter Papers for Polystyrene Latex Aerosols
- Monitoring of Tritium Discharged from the Fuel Reprocessing Test Plat of JAERI
- Monitoring of Gaseous Krypton-85 Released from the Fuel Reprocessing Test Plant of JAERI
- Monitoring of Airborne Radioiodine Released from the Fuel Reprocessing Test Plant of JAERI
- Experiences of Radiation Monitoring in the Fuel Reprocessing Test Plant
- タイトル無し
- タイトル無し
- タイトル無し
- Method for Assessing Neutron Dose Equivalent Rate in Operational Health Physics
- Derivation of the Working Limits of the Skin Surface Contamination
- Performance of Model 7FE Charcoal Filter for the Removal of Airborne Radioiodine:1. In-place Test for the Design of Air Cleaning System at Iodine-131 Production Facilities
- Variation of mutation frequency in Tradescantia stamen hairs cultivated near to a power reactor site.
- Performance of Gas Monitor Employed at Fuel Reprocessing Test Plant of JAERI
- Derivation of Investigation Level for Nose Smear Sample to Assess Internal Exposure
- タイトル無し
- GM管式サーベイメータ用簡易型ガンマ線校正装置
- Characteristic of 16N high energy .GAMMA.-ray irradiation field for calibrating radiation measuring instruments.
- Determination of counting efficiency of NaI(Tl) detector for radioactivity measurement of large .GAMMA.-ray plane sources.
- タイトル無し
- On the plateau characteristics of 2π gas flow proportional counter
- Notes from Radiation Workers (Vol.18, No.2)
- Caluculation on Deposition Loss of Particles in a Straight Conduit for Determining the Aerosol Sampling Conditions
- Organization of Health Physics and Safety in U.K.A.E.A.
- タイトル無し
- タイトル無し
- Establishment of fluorescent X-ray irradiation field for calibrating radiation measuring instruments.