X線回折装置の放射線防護
スポンサーリンク
概要
- 論文の詳細を見る
For the purpose of radiation protectien against X-ray diffraction apparatus, thc followings were carrried out: (i) Measurements of the exposure rates of the primary and scattered X-rays produced from the apparatus, (ii) Determinations of the sensitivity of many types of surveymeters for the low energy X-rays from the apparatus, and (iii) Experiments on the shielding effect of many kinds of materials such as vinyl sheet, rubber, etc..<BR>Exposure rate of about 600R/min was observed for the primary X-rays at the sample holder of the apparatus under the normal operation. For the 8 keV X-rays emitted from the apparatus, the readings of an ionization chamber type surveymeter (ICS-10lC) which was dcsigned for X-rays were in good agreement with those of thc Victoreen r-meter, whereas the readings of the ionization chamber type surveymeter made for γ-rays indicated about one half of those of the Victoreen r-meter. The shielding effects of several materials such as polyethylen, rubber, cotton cloth, etc. were measured. Among them, vinyl sheet had the greatest shielding effect.<BR>Survery technique and assessment of absorbed dose are described in appendix.
著者
-
長谷川 圭佑
日本原子力研究所大洗研究所安全管理課
-
西 健雄
日本原子力研究所保健物理部
-
南 賢太郎
日本原子力研究所
-
西 健雄
日本原子力研究所大洗研究所安全管理課
-
山田 典一
日本原子力研究所大洗研究所安全管理課
-
三戸 規生
日本原子力研究所大洗研究所安全管理課
-
三戸 規生
日本原子力研究所大洗研究所
関連論文
- 個人線量計国際相互比較
- 原子炉事故時における日本の典型的な家屋の放射線遮蔽効果
- 各種建築材料のγ線減弱係数および線量ビルドアップ係数
- X線回折装置の放射線防護
- Monitoring of Tritium Discharged from the Fuel Reprocessing Test Plat of JAERI
- Monitoring of Gaseous Krypton-85 Released from the Fuel Reprocessing Test Plant of JAERI
- Monitoring of Airborne Radioiodine Released from the Fuel Reprocessing Test Plant of JAERI
- Application of artificial intelligence to radiation control. (I). Development of expert system for transport of radioactive material with UTI-LISP programming language.:Development of Expert System for Transport of Radioactive Material with UTI-LISP Progr
- タイトル無し
- Method for Assessing Neutron Dose Equivalent Rate in Operational Health Physics
- Derivation of the Working Limits of the Skin Surface Contamination
- Performance of Gas Monitor Employed at Fuel Reprocessing Test Plant of JAERI
- GM管式サーベイメータ用簡易型ガンマ線校正装置
- Effects of the Relative Humidity on Track Fading and Prevention of Fading of the Personal Neutron Monitoring Film
- タイトル無し
- Characteristic of 16N high energy .GAMMA.-ray irradiation field for calibrating radiation measuring instruments.
- Determination of counting efficiency of NaI(Tl) detector for radioactivity measurement of large .GAMMA.-ray plane sources.
- タイトル無し
- On the plateau characteristics of 2π gas flow proportional counter
- Notes from Radiation Workers (Vol.18, No.2)
- タイトル無し
- Notes from Radiation Workers (Vol. 18, No. 1)