Collection Efficiency of Air Sampling Filter Papers for Polystyrene Latex Aerosols
スポンサーリンク
概要
- 論文の詳細を見る
The collection efficiency of nine types of filter papers for air sampling was determined for monodispersed polystyrene latex aerosols by using a forward light scattering photometer. The aerosols were 0.091, 0.198, 0.365, 0.500 and 1.099μm in diameter, which flowed through a test filter paper at a face velocity from 4.2 to 200cm/sec.Toyo No. 660, No. 60 and No. LP filter papers exhibited minimum efficiencies at the face velocity range between 10 and 80cm/sec, and in the particle size range between 0.1 to 0.5μm. The collection efficiencies of Toyo No. 5A and Whatman No. 41 filter papers were over 95% for all the particle sizes at a face velocity higher than 100cm/sec. Toyo HE-40, HV-70, Toyo GB-100 and Gelman. E filter papers showed the collection efficiencies as high as more than 99%. The theoretical filter efficiency based on single fiber filtering mechanisms and the effect of neighboring fiber interference on the collection efficiency are also discussed.
著者
-
村田 幹生
日本原子力研究所安全性試験研究センター燃料サイクル安全工学部エアロゾル安全工学研究室
-
池沢 芳夫
日本原子力研究所保健物理安全管理部
-
吉田 芳和
日本原子力研究所保健物理安全管理部
-
松本 昌志
東洋濾紙株式会社研究所
-
大畑 勉
日本原子力研究所保健物理安全管理部
-
村田 幹生
日本原子力研究所保健物理安全管理部
-
吉田 芳和
日本原子力研究所
関連論文
- 改良型放射性エアロゾルサンプリング用セルロース・ガラス繊維濾紙の特性
- 着用時における浄気式全面, 半面マスクの防護性能
- BWR運転時の放射性気体廃棄物の放出基準の検討
- 曲管内のエアロゾル粒子沈着
- チェルノブイリ原子炉事故によるソ連, ヨーロッパ諸国ならびに日本の汚染, および緊急時対応の概要
- 放射線管理コーナー (16巻3号) : 制動X線法によるトリチウム汚染試料の測定
- 放射線管理とエアロゾル
- 大気エアロゾルに対する放射性元素状ヨウ素ガスの吸着特性
- 放射性元素状ヨウ素ガスのフライアッシュエアロゾルに対する吸着特性
- 線香エアロゾルを用いた放射性元素状ヨウ素ガスの吸着特性の研究
- 放射性硫化水素ガス (H235S) に対する活性炭素繊維フィルタ捕集効率の評価法
- タイトル無し
- Collection Efficiency of Air Sampling Filter Papers for Polystyrene Latex Aerosols
- Estimation by Smearing of the Level of Tritium Surface Contamination
- Development of activated carbon fiber filter used for airborne radioiodine monitoring.
- Application of artificial intelligence to radiation control. (I). Development of expert system for transport of radioactive material with UTI-LISP programming language.:Development of Expert System for Transport of Radioactive Material with UTI-LISP Progr
- タイトル無し
- タイトル無し
- タイトル無し
- Experiments on the evaluation of protection provided by full-face masks as worn. Decision of sampling position at masks and correction of the measured aerosol concentration.:Decision of Sampling Position at Masks and Correction of the Measured Aerosol Con
- Determination of Alpha Emitting Particle Size by the Autoradiography Using ZnS (Ag) Powder Screen
- タイトル無し
- Method for Assessing Neutron Dose Equivalent Rate in Operational Health Physics
- タイトル無し
- Evaluation of Protection Factors Provided by Full-face Masks Using Man-test Method at Workplace.
- Variation of mutation frequency in Tradescantia stamen hairs cultivated near to a power reactor site.
- Derivation of Investigation Level for Nose Smear Sample to Assess Internal Exposure
- タイトル無し
- Caluculation on Deposition Loss of Particles in a Straight Conduit for Determining the Aerosol Sampling Conditions
- Organization of Health Physics and Safety in U.K.A.E.A.
- タイトル無し
- タイトル無し