Decontamination Factors (DFs) of HEPA filter were measured against 239Pu oxide aerosols. Collection performance of HEPA filter media was investigated using monodisperse NaCl aerosols at various air flow face velocities. From the penetration curves the most penetrating particle size, MPPS, and the maximum penetration, Pmax, were obtained in each face velocity. The MPPSs at 0.8-11cm s-1 flow were not found in 0.3μm size range but in 0.1-0.15μm size range. The reciprocal of Pmax, which means the minimum of decontamination factor, DFmin, linearly increased with decreasing face velocity in a logarithmic paper. Experimental DFs against Pu aerosols in the MPPS range were nearly equal to the DFmin, and the others were always larger than the DFmin. This means that there are no differences between Pu and NaCl aerosols in terms of filtration. The DFmin estimated from the nonradioactive test aerosols is important for evaluating the performance of HEPA filters in the radiation protection field.
著者
関連論文
- 室内エアロゾルの性状変化とそれに関連したラドン娘核種吸入に基づく線量換算係数の変動
- 地下公共施設におけるラドン濃度測定と線量評価 - 福岡市天神地下街 -
- パッシブ型ラドン測定器のトロンに対する応答特性
- ICRPのヒト呼吸気道モデル66における生体パラメータがエアロゾル沈着に及ぼす影響 : 日本人とコーカシアン人
- ラットにおける吸入硝酸プルトニウムに対するCa-DTPA注射の初期投与の効果
- スクリーン型拡散バッテリー法における測定時間の短縮と解析精度
- 実験計画のためのエアロゾル計数に関する統計的考察
- スクリーン型拡散バッテリーの最適装置条件に関する考察
- 6. アルファ放射体内部被曝生物影響研究 -プルトニウム発がん実験を中心に-
- 専門学校における^Rnおよびその壊変核種の測定
- 大気中ラドン・トロン濃度に及ぼす地質, 地表面の相違
- 第27回放医研環境セミナーの概要
- 緊急時医療措置としてのCa-DTPAの吸入投与法
- エアフィルタの目詰まりの季節変動
- Lung Retention of Pu Following Inhalation of PuO2 in Rats Measured Using a Whole Body Counter
- Effects of DTPA Therapy on Removal of Inhaled High-fired Plutonium Oxide in Rats
- P-103 毛根細胞を用いたコメット法による放射線局所被ばく評価法の開発(ポスターセッション)
- 「フィルタ捕集性能研究 : ピンホール効果」その後
- 3. プルトニウムの吸入投与実験
- PTFE・ガラス繊維素材フィルタのエアロゾル捕集性能
- 繊維層フィルタのピンホールに対する粒子透過モデル
- 現場試験用0. 15μm単分散DOPエアロゾル発生装置の開発
- 第12回 エアロゾル科学・技術研究討論会 研究討論会報告
- 地下街およびその近傍の地上部における浮遊粒子状物質の粒子径分布と呼吸気道各部への局所沈着率
- ラドン研究の最前線と住居内ラドン濃度規制の動き
- 水中ラドンに起因する健康リスク
- 20周年記念事業 : 第1回市民講座「暮らしの中のエアロゾル」
- 欧州ラドン実験研究施設視察記
- A Comparison of Different Laser Aerosol Spectrometers for Measurement of Particle Penetration through a Medium Efficiency Air Filter
- On the Error Due to the Window Width of Particle Size Analyzer in the Measurement of Particle Penetration through an Air Filter
- 0.3μm以下の粒子に対するエアフィルタの粒子捕集性能
- セミナー : ディーゼル排気粒子 (DEP) 研究の最新情報
- プルトニウムエアロゾル : その性状と空気汚染管理
- Characteristics of Plutonium Oxide Aerosol Particles Generated by Nebulization.
- Studies on Collection Performance of HEPA Filter against Pu Aerosols.
- Deposition of Ultrafine Aerosol Particles in a Human Tracheobronchial Cast.
- Dependency on face velocity of performance of aerosol sampling filter.
- 小動物用放射性エアロゾル吸入実験装置の開発とその基礎特性
- Simple method of size estimation of radioactive aerosols in air monitoring.
- Pulmonary deposition and clearance of inhaled or instilled 198Au-colloid in the rat after the induction of pulmonary delayed type hypersensitivity reactions.
- Recent Studies on Health Effects Related to Aerosols
- Techniques for Inhalation Exposure Experiments
- Collection efficiency and decontamination factor of HEPA filter.