Megavoltage Photon Beam Attenuation by Carbon Fiber Couch Tops and its Prediction Using Correction Factors
スポンサーリンク
概要
- 論文の詳細を見る
The purpose of this study was to evaluate the effect of megavoltage photon beam attenuation (PBA) by couch tops and to propose a method for correction of PBA. Four series of phantom measurements were carried out. First, PBA by the exact couch top (ECT, Varian) and Imaging Couch Top (ICT, BrainLAB) was evaluated using a water-equivalent phantom. Second, PBA by Type-S system (Med-Tec), ECT and ICT was compared with a spherical phantom. Third, percentage depth dose (PDD) after passing through ICT was measured to compare with control data of PDD. Forth, the gantry angle dependency of PBA by ICT was evaluated. Then, an equation for PBA correction was elaborated and correction factors for PBA at isocenter were obtained. Finally, this method was applied to a patient with hepatoma. PBA of perpendicular beams by ICT was 4.7% on average. With the increase in field size, the measured values became higher. PBA by ICT was greater than that by Type-S system and ECT. PBA increased significantly as the angle of incidence increased, ranging from 4.3% at 180° to 11.2% at 120°. Calculated doses obtained by the equation and correction factors agreed quite well with the measured doses between 120° and 180° of angles of incidence. Also in the patient, PBA by ICT was corrected quite well by the equation and correction factors. In conclusion, PBA and its gantry angle dependency by ICT were observed. This simple method using the equation and correction factors appeared useful to correct the isocenter dose when the PBA effect cannot be corrected by a treatment planning system.
著者
-
SHIBAMOTO Yuta
Department of Radiology, Nagoya City University Hospital
-
HAYASHI Naoki
Faculty of Radiological Technology, School of Health Science, Fujita Health University
-
OBATA Yasunori
Graduate school of Medicine, Nagoya University
-
KIMURA Takashi
Nagoya Radiosurgery Center, Nagoya Kyoritsu Hospital
-
NAKAZAWA Hisato
Nagoya Radiosurgery Center, Nagoya Kyoritsu Hospital
-
HAGIWARA Masahiro
Nagoya Radiosurgery Center, Nagoya Kyoritsu Hospital
-
HASHIZUME Chisa
Nagoya Radiosurgery Center, Nagoya Kyoritsu Hospital
-
MORI Yoshimasa
Nagoya Radiosurgery Center, Nagoya Kyoritsu Hospital
-
KOBAYASHI Tatsuya
Nagoya Radiosurgery Center, Nagoya Kyoritsu Hospital
関連論文
- Simultaneous Analysis of Marrow Fat Fraction and Bone Mineral Density with Modulus and Real Multiple Gradient-echo MRI
- Biological Effects of Field Emission-Type X-Rays Generated by Nanotechnology
- Megavoltage Photon Beam Attenuation by Carbon Fiber Couch Tops and its Prediction Using Correction Factors
- Megavoltage Photon Beam Attenuation by Carbon Fiber Couch Tops and its Prediction Using Correction Factors
- A Novel Class of Antitumor Prodrug, 1-(2'-Oxopropyl)-5-fluorouracil (OFU001), That Releases 5-Fluorouracil upon Hypoxic Irradiation
- Changes in Cell Proliferative Parameters of SCCVII and EMT6 Murine Tumors after Single-dose Irradiation
- Comparison of in vivo Efficacy of Hypoxic Cytotoxin Tirapazamine and Hypoxic Cell Radiosensitizer KU-2285 in Combination with Single and Fractionated Irradiation
- Is targeted reconstruction necessary for evaluating contrast-enhanced chest computed tomography using a liquid crystal display monitor?
- Comparison of 16-multidetector-row computed tomography and angiocardiography for evaluating the central pulmonary artery diameter and pulmonary artery index in children with congenital heart disease
- Radiotherapy for metastatic brain tumors
- Multivariate Analysis of Dissemination Relapse of Medulloblastoma and Estimation of Its Time Parameter for Craniospinal Irradiation
- Estimation of Time Parameter of LQ-model in Fractionated Radiotherapy of Medulloblastoma
- ESTIMATION OF γ/α (TIME PARAMETER OF LQ-MODEL) IN RADIOTHERAPY OF MEDULLOBLASTOMA
- Effect of a Hypoxic Cell Sensitizer Doranidazole on the Radiationinduced Apoptosis of Mouse L5178Y Lymphoma Cells
- A problem in diagnosing N3 disease using FDG-PET in patients with lung cancer : High false positive rate with visual assessment
- False-positive and true-negative hilar and mediastinal lymph nodes on FDG-PET : Radiological-pathological correlation
- Radiographic Findings of Aberrant Right Subclavian Artery Initially Depicted on CT
- Effect of Low-Dose Total-Body Irradiation on Transplantability of Tumor Cells in Syngeneic Mice
- Low-Dose Whole-Body Irradiation Induced Radioadaptive Response in C57BL/6 Mice
- Reevaluation of the Radiosensitizing Effects of Sanazole and Nimorazole In Vitro and In Vivo
- Biological Effects of Intermittent Radiation in Cultured Tumor Cells : Influence of Fraction Number and Dose Per Fraction
- Malignant Lymphoma Arising in the Cerebral Parenchyma Adjacent to a Parasagittal Meningioma : Case Report
- Therapeutic Approach to Chordoid Glioma of the Third Ventricle:—Three Case Reports and Review of the Literature—
- Trigeminal Neuralgia Caused by Nerve Compression by Dilated Superior Cerebellar Artery Associated with Cerebellar Arteriovenous Malformation: Case Report