Experimental Study of a Novel Method of Cardiopulmonary Resuscitation Using a Combination of Percutaneous Cardiopulmonary Support and Liposome-encapsulated Hemoglobin (TRM645)
スポンサーリンク
概要
- 論文の詳細を見る
<p>Percutaneous cardiopulmonary support (PCPS) has been applied for cardiopulmonary arrest (CPA). We have developed a novel method of cardiopulmonary resuscitation using PCPS combined with liposome-encapsulated hemoglobin (TRM645) to improve oxygen delivery to vital organs. Ventricular fibrillation was electrically induced to an adult goat for 10 min. Next, PCPS (30 ml/kg/min, V/Q: 1) was performed for 20 min. Then, external defibrillation was attempted and observed for 120 min. The TRM group (n5) was filled with 300 mL of TRM645 for the PCPS circuit. The control group (n5) was filled with the same volume of saline. The delivery of oxygen (DO2) and oxygen consumption (VO2) decreased markedly by PCPS after CPA, compared to the preoperative values. DO2 was kept at a constant level during PCPS in both groups, but VO2 slowly decreased at 5, 10, and 15 min of PCPS in the control groups, demonstrating that systemic oxygen metabolism decreased with time. In contrast, the decreases in VO2 were small in the TRM group at 5, 10, and 15 min of PCPS, demonstrating that TRM645 continuously maintained systemic oxygen consumption even at a low flow rate. AST and LDH in the TRM group were lower than the control. There were significant differences at 120 min after the restoration of spontaneous circulation (p<0.05).</p>
- Okayama University Medical Schoolの論文
著者
関連論文
- モノピボット遠心血液ポンプの開発と血液適合性評価
- 20317 補助循環用動圧浮上式血液ポンプの血液適合性評価(人工臓器と医用工学(4),OS.8 人工臓器と医用工学)
- 20316 ステップ動圧軸受の最適化による動圧浮上遠心ポンプの血液適合性改善(人工臓器と医用工学(4),OS.8 人工臓器と医用工学)
- 0404 連続流型補助人工心臓の耐久試験法に関する検討(OS22:機械式循環補助)
- 0403 体内埋込型補助人工心臓用軸流ポンプの生体適合性評価(OS22:機械式循環補助)
- 20307 表面粗さを付加した回転せん断負荷装置内の流動解析(人工臓器と医用工学(2),OS.8 人工臓器と医用工学)
- 20306 せん断流れ場において血液接触面の表面粗さが血球破壊に与える影響(人工臓器と医用工学(2),OS.8 人工臓器と医用工学)
- 回転型血液ポンプの流れの可視化
- Investigation of unifying transcutaneous transformer for transmission of energy and information
- Observation of cavitation pits on a mechanical heart valve surface in an artificial heart used in in vivo testing
- Effects of leaflet geometry on the flow field in three bileaflet valves when installed in a pneumatic ventricular assist device
- Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart
- Development of a compact wearable pneumatic drive unit for a ventricular assist device
- Experimental Study of a Novel Method of Cardiopulmonary Resuscitation Using a Combination of Percutaneous Cardiopulmonary Support and Liposome-encapsulated Hemoglobin (TRM645)
- Characteristics of cavitation intensity in a mechanical heart valve using a pulsatile device : synchronized analysis between visual images and pressure signals
- Oxygen metabolism during cardiopulmonary bypass with hemodilution using liposome-encapsulated hemoglobin in kid goats
- Up to 151 days of continuous animal perfusion with trivial heparin infusion by the application of a long-term durable antithrombogenic coating to a combination of a seal-less centrifugal pump and a diffusion membrane oxygenator
- Development of a compact portable driver for a pneumatic ventricular assist device
- Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device
- Mechanism for cavitation of monoleaflet and bileaflet valves in an artificial heart
- Monitoring of Diaphragm Position in Pulsatile Pnumatic Ventricular Assisted Device by Ultrasound Sensor : A New Method for Flow Measurement in VAD(Bioengineering)
- A Study on the Mechanism for Cavitation in the Mechanical Heart Valves with an Electrohydraulic Total Artificial Heart(Bioengineering)
- Observation of cavitation bubbles in monoleaflet mechanical heart valves
- Observation of alveolar fibrosis in a goat following venoarterial bypass for up to 5 months using extracorporeal membrane oxygenation
- Closing behavior of the mechanical heart valve in a total artificial heart
- Shear Evaluation by Quantitative Flow Visualization Near the Casing Surface of a Centrifugal Blood Pump(Reviewed Papers Accepted for Publication in this Special Issue)(Special Issue on Bioengineering)
- Proliferative changes in the media of the afferent arterioles under prolonged continuous-flow left heart bypass
- Analysis of specific absorption rate in biological tissue surrounding transcutaneous transformer for an artificial heart
- 1005 補助循環用動圧浮上式遠心ポンプの軸受隙間評価(OS2-(2) ライフサポートにおける工学技術,オーガナイズドセッション)
- Influence of varying conduit resistance on native heart function with nonpulsatile left heart bypass
- 1010 血液のせん断流れ場において金属材料表面粗さが溶血に及ぼす影響(OS2-(3) ライフサポートにおける工学技術,オーガナイズドセッション)
- Effect of prolonged nonpulsatile left heart bypass on vascular control status
- 0401 機械的血液循環補助の技術動向(OS22:機械式循環補助)
- 1009 表面粗さを付加した回転せん断付加装置内の数値解析(OS2-(3) ライフサポートにおける工学技術,オーガナイズドセッション)
- Visualization of flow structure in a centrifugal blood pump impeller
- Current status of development and in vivo evaluation of the National Cardiovascular Center electrohydraulic total artificial heart system
- Aortic reaction to prolonged nonpulsatile left heart bypass
- Pivot wear of a centrifugal blood pump developed for circulatory assist
- Transient response of remnant atrial heart rate to step changes in total artificial heart output
- Observation of cavitation pits on mechanical heart valve surfaces in an artificial heart used in in vitro testing
- Radial-Type Self-Bearing Motor for Nonpulsatile-Type Artificial Heart
- らせん流ポンプ内流れの可視化評価
- A102 遠心血液ポンプの数値流体力学解析による血液適合性評価(A1-1 生体流体工学1)
- 515 MERAモノピポット遠心ポンプの耐久性と血液適合性(OS5-(3)オーガナイズドセッション《ライフサポートにおける工学技術》)
- 8F-08 遠心血液ポンプのin vitro抗血栓試験における血液凝固因子濃度測定(OS-1(2) 循環器系のバイオメカニクスと医療機器設計(2))
- 8F-03 拍動流下における連続流型補助人工心臓の耐久性試験方法の改善(OS-1(2) 循環器系のバイオメカニクスと医療機器設計(1))
- 8F-01 小柄患者用補助人工心臓の技術開発の必要性(OS-1(2) 循環器系のバイオメカニクスと医療機器設計(1))
- 517 高粘度血液のせん断流れ場において表面粗さとせん断応力が溶血に及ぼす影響(OS5-(3)オーガナイズドセッション《ライフサポートにおける工学技術》)
- Initial in vivo evaluation of the newly developed axial flow turbo pump with hydrodynamic bearings
- A novel counterpulse drive mode of continuous-flow left ventricular assist devices can minimize intracircuit backward flow during pump weaning
- What is the ideal off-test trial for continuous-flow ventricular-assist-device explantation? Intracircuit back-flow analysis in a mock circulation model
- モノピボット遠心血液ポンプの実用化開発 : 製品につながる医工連携とは
- A novel counterpulsation mode of rotary left ventricular assist devices can enhance myocardial perfusion
- Neointima-inducing inflow cannula with titanium mesh for left ventricular assist device
- Computational fluid dynamic analysis of the flow field in the newly developed inflow cannula for a bridge-to-decision mechanical circulatory support
- Development and long-term in vivo testing of a novel skin-button system for preventing driveline infection of an implantable VAD system
- Development of a miniaturized mass-flow meter for an axial flow blood pump based on computational analysis
- 412 コーン・シリンダー型レオメーターを使用したせん断流れ場におけるウシ血液の溶血特性(OS5-(4)オーガナイズドセッション《ライフサポートにおける工学技術》)
- 414 遠心血液ポンプの動圧軸受形状がインペララジアル安定性と溶血に及ぼす影響(OS5-(4)オーガナイズドセッション《ライフサポートにおける工学技術》)
- 413 PIVによる曲がり管式質量流量計内の速度分布の計測(OS5-(4)オーガナイズドセッション《ライフサポートにおける工学技術》)
- 8E15 小型血液質量流量計の計測精度に及ぼす断面形状の影響(OS24 人工臓器の実用化について1)
- 8E14 拍動流下における軸流型補助人工心臓の耐久性試験方法の設計指標(OS24 人工臓器の実用化について1)
- S021011 拍動流下における連続流型補助人工心臓の耐久性試験方法に対する検討([S02101]人工臓器におけるバイオメカニクス(1))