This paper describes design, fabrication, and evaluation of a dual-purpose element for micro total analysis system (μTAS). The element approached two functions for μTAS applications. One is a micropump which transports the liquid and the other is a micromixer which stirs the liquid. It is possible to downsize a system with densely-integrated system by developing a dual-purpose element. These functions are obtained by ultrasonic vibration. The micropump uses a traveling vibration on an ultrasonic vibrator and the micromixer uses a standing vibration of it. The ultrasonic vibrator is composed of a piezo element (piezoelectric zirconate titanate, PZT) disk (φ20mm×0.5mm), a brass disk (φ20mm×2mm) and a phosphor bronze disk (φ30mm×0.1mm). The liquid chamber is φ28mm×1mm. The mixing experiment confirms the effectiveness of the proposed mixing principle.